Records from 2017 to 2026. Most recent: inspection, 6 April 2026.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 April 2026
Resolved
The main steering gear and rudder stock shall be: capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. PSCO observed rudder only capable of reaching 33 degrees to port while operating on the NO. 2 steering pump.
74 SOLAS (amend.) II-1/29.3.2
Prior to Movement, 60 ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 April 2026
Resolved 7 April 2026
Resolution: Received, reviewed, and accepted class report from RINA stating that the steering gear feedback chain associated with no. 2 steering pump was adjusted, and system tested with satisfactory results.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 6 April 2026
Resolved
In the event of a power failure to any one of the steering gear power units, an audible and visual alarm shall be given on the navigation bridge. PSCO observed extinguished visual indicators for power failure on bridge steering alarm panel.
74 SOLAS (amend.) II-1/29.5.2
Prior to Movement, 60 ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 April 2026
Resolved 7 April 2026
Resolution: Received, reviewed, and accepted class report from RINA stating that the steering alarm panel fuse was found burst, replaced with a new fuse, and system tested with satisfactory results.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 April 2026
Resolved
Rescue boat shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. PSCO observed the rescue boat steering was unable to turn to port or starboard.
74 SOLAS (amend.) III/14.1
Prior to Departure, 17 ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2026
Resolved 7 April 2026
Resolution: Received, reviewed, and accepted class report from RINA stating that the steering gear shaft on rescue boat was found wasted and broken, replaced with a new part, and tested with satisfactory results.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 April 2026
Resolved
During preparation and launching, the survival creaft, its launching appliance... shall be adequately illuminated from the emergency source of electrical power. PSCO observed 02 emergency lights in the vicinity of the rescue boat extinguished.
74 SOLAS (AMEND) III/16.7
Rectified to the satisfaction of the CG, 10 c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 April 2026
Resolved 6 April 2026
Resolution: Ship's crew replaced extinguished bulbs to the satisfaction of attending PSCO.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 April 2026
Resolved
The following functional requirements shall be met: dangerous goods shall be adequately separated from ignition sources. PSCO observed exposed wiring on overhead light between no. 4 and no. 5 holds. Renew damaged light prior to handling of dangerous goods.
74 SOLAS (amend.) II-2/19.1.2
Rectify prior to handling of dangerous goods, ac.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2026
Resolved 7 April 2026
Resolution: Received, reviewed, and accepted class report from RINA stating that a temporary repair mitigating the electrical hazard has been conducted to their satisfaction, with permanent repairs required by 31MAY2026 per RINA issued Condition of Class.