Inspection history · 19
5 March 2026
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8320726
5 September 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8207583
7 February 2025
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8067051
12 September 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8001084
13 June 2023
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7647658
2 February 2023
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7605980
26 September 2022
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7566761
7 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7553110
1 September 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7306973
4 February 2021
Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7136025
13 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7072014
31 July 2019
Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6781438
19 June 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6721320
7 February 2019
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6621716
31 August 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6618385
14 June 2018
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6421845
5 October 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6281632
8 February 2017
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6083983
21 October 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6025275
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 September 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Approximately 30 life jackets were not marked with appropriate retroreflective material that was losing reflective properties. Provide appropriate markings to the satisfaction of the attending marine inspector.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2025
Resolution: Retro tape was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2025
Resolved
Each hatch cover must be attached to the hatch frame by hinges, captive chains, or other securing device such as a lanyard to prevent loss. Port side engine room hatch was missing a lanyard.
46 CFR 174.220(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2025
Resolution: Lanyard was replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 5 September 2025
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR 159. Wire tie shut both MSD overboard valves.
46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2025
Resolution: Valve was wired shut.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's port remote fuel shutoff valve did not fully close the valve.
46 CFR 182.455(b)(4)
10C
Action required: 10 - Deficiency Rectified
Due 13 June 2023
Resolved 13 June 2023
Resolution: Vsl crew repaired pull cable that was preventing the valve from fully opening.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 September 2022
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Gauge for oil pressure was broken. Replace gauge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 26 September 2022
Resolution: Vessel sent satisfactory evidence of replacement of gauge, cleared deficiency.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 7 September 2022
Resolved
Each unpressurized fuel tank must be fitted with a vent pipe connected to the highest point of the tank. The discharge end of the stbd fuel tank vent pipe was corroded closed. Replace corroded end of discharge fuel tank vent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 20 September 2022
Resolution: Operator sent satisfactory evidence of new fuel vent.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2020
Resolved
A self priming, power driven fire pump must be installed on each vessel: of not more than 19.8 meters (65 feet) in length that carries more than 49 passengers. The fire pump does not provide pressure and is inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2020
Resolution: Satisfactory ops check of the fire pump, nozzel, and hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected an all required grads and protective devices must be in satisfactory condition. The starboard shaft seal is leaking at an unacceptable rate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2020
Resolution: Inspected the starboard shaft seal while underway and no water leakage was observed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 October 2020
Resolved
A vessel must comply with the applicable requirements for any radio and (EPRIB) installations, including the requirements for a station license and installation certificates to be issude by the FCC, as set forth in 47 CFR 80. The VHF radio display screen in inoperable and does not display any information.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2020
Resolution: New VHF radio was installed and inspected. MMSI, GPS, and satisfactory ops check were verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 October 2020
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The starboard engine RPM gauge in inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 25 November 2020
Resolution: RPM gauge replace in-kind. Operational test was satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 October 2020
Resolved
A hatch cover must have a securing device and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The port watertight engine compartment hatch does not have a securing device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 26 October 2020
Resolution: Port watertight engine compartment hatch lanyard was installed and secured to the hatch.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2020
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The aspirin in the first-aid kit has expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 26 October 2020
Resolution: New aspirin was installed in the first-aid kit.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 August 2019
Resolved
Vessel is constructed with general purpose resin (Endurance Resin 4217A). When the hull, bulkheads, decks, deckhouse, or superstructure of a vessel is partially or completely constructed of a composite material, including fiber reinforced plastic, the resin used must be fire retardant and meet as accepted by the Commandant as meeting NPFC MIL-R-21607E(SH) (incorporated by reference, see 46 CFR 175.600).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 September 2019
Resolved 9 October 2019
Resolution: Submitted plans for arrangement of grill and provided equivalent level of safety. Arrangement approved per plan approval ltr dtd 09OCT2019.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2019
Resolved
Complete sea trials in presence of attending Coast Guard Inspector prior to receiving drydock credit.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 19 February 2019
Resolution: Sea Trials completed.
Engineering › Bilge Water Management System › Pump
Issued 21 October 2016
Resolved
BILGE PUMP PORT SIDE INOPERABLE; ENSURE BILGE PUMP PROVIDES ADEQUATE SUCTION TO SUCTION HEADS IAW 46 CFR 182.50
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2016
Resolution: IDENTIFIED/REPAIRED STUCK VALVE IN BILGE PIPING AND DEMONSTRATED SATISFACTORY OPERATION OF THE BILGE PUMP TO PROVIDE SUCTION TO THE BILGE LINES
Communications › Alarms/Indicators › High Water Alarm
Issued 21 October 2016
Resolved
BILGE HIGH LEVEL ALARM VISUAL INDICATORS INOPERABLE; ENSURE BILGE HIGH LEVEL VISUAL ALARMS ARE FUNCTIONAL IAW 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 7 November 2016
Resolution: BILGE HIGH LEVEL ALARM VISUAL INDICATORS REPLACED.
Engineering › Fuel Oil Service System › Hose
Issued 21 October 2016
Resolved
FUEL LINES TO PORT/STARBOARD ENGINES WEARING THROUGH DUE TO RESTING ON ENGINE; PROVIDE CHAFFING GEAR TO FUEL LINES IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 7 November 2016
Resolution: Chaffing gear provided for fuel lines.
Fire Fighting › Fire Pumps › Pressure
Issued 21 October 2016
Resolved
GUAGE ON FIRE PUMP MISSING; INSTAL GUAGE ON FIRE PUMP IAW 46 CFR 181.300(d)
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 7 November 2016
Resolution: Guage installed on fire pump.
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 21 October 2016
Resolved
Starboard engine compartment fire boundary lagging detatched from overhead; repair IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 7 November 2016
Resolution: Starboard engine compartment fire boundary lagging re-attached.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 October 2016
Resolved
One life jacket missing from total count; provide additional life jacket IAW 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 7 November 2016
Resolution: New life jacket purchased and installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 October 2016
Resolved
Light list out of date; provide updated light list IAW 46 CFR 184.420
Condition: Invalid
Due 4 November 2016
Resolved 7 November 2016
Resolution: Light list on board updated.
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 October 2016
Resolved
Coast Pilot out of date; provide current Coast Pilot IAW 46 CFR 184.420
Condition: Invalid
Due 4 November 2016
Resolved 7 November 2016
Resolution: Coast Pilot on board updated.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 October 2016
Resolved
Portable fire extinguisher brackets not CG approved type; replace IAW 46 CFR 181.500
Condition: Improper Installation
Due 4 November 2016
Resolved 8 November 2016
Resolution: Mounting bracket for portable fire extinguishers replaced.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 October 2016
Resolved
Circuit breakers installed are not UL 489 approved; replace with UL 489 approved circuit breakers IAW 46 CFR 183.380
Condition: Improper Installation
Due 4 November 2016
Resolved 17 November 2016
Resolution: Circuit breakers installed meet UL 489 standard.