RENEE

RENEE is a 2015 offshore supply vessel. The Coast Guard has recorded 33 inspections since 2016, most recently in May 2026, along with 19 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 20 May 2026.

Built
2015
Last inspected
20 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9704271
WDH7420
1207410
Flag
UNITED STATES
Maury page id
psix-1207410

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)254.9 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 3,117 / net 1,221
ITC dimensions (L × B × D)254.9 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,117 / net 1,221
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 26 August 2025 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1221 - Convention (Subpart B), Net Ton
3117 - Convention (Subpart B), Gross Ton
4914 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 33

20 May 2026 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8369451
18 March 2026 ACP Annual Oversight · Re-Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8312034
10 February 2026 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8306185
23 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8284964
5 November 2025 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8264795
21 September 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8238176
22 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8192801
7 July 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8174196
2 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8127588
6 January 2025 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8058977
22 November 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8038750
5 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874630
20 May 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7692788
20 May 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7713451
12 April 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7666151
20 January 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7624694
2 February 2022 Periodic Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7390048
7 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170186
1 February 2021 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7134195
29 January 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7136293
11 June 2020 Appeal · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6974310
3 February 2020 COI Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6895024
10 January 2020 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6886742
21 July 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6758662
15 March 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663865
27 March 2018 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6379296
12 January 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6340013
12 July 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6206775
6 February 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6083534
11 January 2017 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6071852
11 January 2017 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6078392
11 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5831361
17 February 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5817095

Deficiency record · 19

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2025 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to provide services necessary for safety under normal and emergency conditions. Port generator failure. Generator needs to be repaired to normal operational conditions.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 16 May 2025
Resolved 15 May 2025
Resolution: Recieved ABS report Deficiency cleared.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 6 March 2024 Resolved
ALL SYSTEMS FOR DETECTING SMOKE AND FIRE, INCLUDING SENSORS, AND ALARMS, MUST BE INSPECTED AND TESTED. AFT FIRE DETECTOR DID NOT ALARM DURING TESTING.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 21 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2024 Resolved
EACH VESSEL MUST BE EQUIPPED WITH ONE-SELF PRIMING POWER DRIVEN FIRE PUMP CAPABLE OF DELIVERING A SINGLE STREAM OF WATER FROM THE HIGHEST HYDRANT, THROUGH THE HOSE AND NOZZLE AT A PITOT-TUBE PRESSURE OF AT LEAST 50 POUNDS PER SQUARE INCH. PORT SIDE FiFi SYSTEM MALFUNCTIONED. VESSEL CAN NOT OPERATE WITHIN THE STANDBY SERVICE UNTIL FiFi SYSTEM IS REPAIRED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 21 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 6 March 2024 Resolved
EACH ENCLOSED SPACE WITHIN THE VESSEL MUST BE PROPERLY VENTED OR VENTILATED. HVAC SYSTEM WAS ROTTED OUT.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 21 March 2024
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 12 April 2023 Resolved
Representative samples of fuel oil are to be retained under the ship's control for not less than 12 months; vessel did not have 12 months of fuel samples available. Confirm sufficient fuel samples on board at next topside inspection. (2011) MARPOL 73/78 VI/18.8.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 January 2025
Resolution: Satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2023 Resolved
Each grounded system must have only one point of connection to ground; 4 amp ground caused by water discovered, found to be caused by water heater. 46 CFR 111.05-13
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 April 2023
Resolution: Isolated water heater via lockout/tagout. Operating with only other water heater until repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 3 February 2022 Resolved
The capacity of the pump for cargo ships of 2000 gross tonnage and upwards shall be 25m3/h; The emergency fire pump did not generate sufficient pressure. FSS 2020/12.2.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Reattended the vessel and witnessed satisfactory pressure for the emergency fire pump.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 February 2022 Resolved
General construction of the vessel such as to minimize fire hazards; Excessive fuel oil was found in the bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Reattended the vessel and saw that condition of bilges were satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 3 February 2022 Resolved
Each machinery space must be ventilated to ensure that when machinery are operating, they have adequate ventilation; Port engine intake blower was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 15 August 2022
Resolution: Port Enginge blower is operable.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 February 2022 Resolved
In a cargo ship, the main steering gear is capable of meeting ability to shift rudder between 35 degrees to 30 degrees within 28 seconds with all available power units on; Starboard steering pump motor start relay was inoperable. 74 SOLAS (14) II-1/29.6.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 15 August 2022
Resolution: The Vessel replaced in king the Starboard steering pump motor start relay.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 February 2022 Resolved
Precautions shall be taken to prevent the nozzles from becoming clogged by impurities in the water or corrosion of nozzles; Water mist nozzles over the starboard main diesel engine were clogged. FSS 2020/7.2.1.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Reattended the vessel and witness operation of water mist nozzles.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 February 2022 Resolved
In accordance with ASTM F1197, a manual control system for a Class 3 watertight door must be capable of closing in not more than 90 seconds; hand crank for the Class 3 watertight door aft of the engine control room was unable to manually close the door in 90 seconds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Reattended the vessel and confirmed closure of door with hand crank.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2022 Resolved
Every lifebuoy shall, if it is intended to operate the quick-release arrangement provided for the self-activated smoke signals and self-igniting lights, have a mass of not less than 4kg; Ring buoy on the starboard side bridge wing was a deck buoy of insufficient size. LSA 2017/2.1.1.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Reattended the vessel and saw that a bridge buoy was in place.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 3 February 2022 Resolved
Each machinery space must be ventilated to ensure that when machinery are operating, they have adequate ventilation; Bow thruster ventilation manual override was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 15 August 2022
Resolution: Vessel replaced in kind the ventilation manual override control.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2022 Resolved
For ships constructed on or after 01JUL14, a minimum of two-way portable radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried on board; The vessel was using the lifeboat radios as the fire team radios since they did not have separate radios for the fire team. 74 SOLAS (14) II-2/10.4
Action required: 702 - Prior to embarking on international voyage
Due 15 August 2022
Resolved 15 August 2022
Resolution: Vessel provided an Invoice for three (3) UHF Fire Fighter Hand Held Radios.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 February 2021 Resolved
Automated vital systems must be designed, constructed, and operate in accordance with the applicable requirements of part 62. Remote level sensor of fuel oil day tank failed to operate properly and provide the correct readout, resulting in a pollution incident. To be rectified by upcoming, scheduled annual inspection. 46 CFR 61.40-3(a)
Action required: 705 - Other - as specified
Due 9 March 2021
Resolved 7 April 2021
Resolution: Witnesses SAT operation.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 March 2018 Resolved
Quick acting fuel shut offs were inoperable due to cracked hydraulic cylinders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2018
Electrical › Electrical Distribution System (emergency) › Cable
Issued 27 March 2018 Resolved
Electrical cable running from EDG to the Emergency Switchboard had split.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 17 April 2018
Resolution: Received verification form ABS surveyor that main power cable had been replaced.
Engineering › Non-conventional Propulsion/Steering › Control Systems (Azipod)
Issued 11 January 2017 Resolved
The CPP system is leaking oil, vessel must be drydocked for repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2017
Resolution: ABS surveyor witnessed repairs, all sat.

Casualty record · 1

20 May 2023Routine · role: Involved in a Marine Casualty · activity 7713451
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.