← All vessels
BBC NAGASAKI
BBC NAGASAKI is a 2011 freight ship. The Coast Guard has recorded 22 inspections since 2014, most recently in November 2025, along with 11 deficiencies and 1 operational control.
Records from 2014 to 2025. Most recent: inspection, 6 November 2025.
- Built
- 2011
- Last inspected
- 6 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9559872 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2FP5
1208258
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1208258
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it3617 - Convention (Subpart B), Net Ton
9717 - Dead Weight, Metric Ton
12856 - Displacement, Metric Ton
6351 - Convention (Subpart B), Gross Ton
9717 - Dead Weight, Metric Ton
12856 - Displacement, Metric Ton
6351 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
6 November 2025
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8265043
9 October 2025
COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8250248
28 March 2024
PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7885231
6 June 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7470494
24 February 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7401486
19 January 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7382681
27 November 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7357832
23 November 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7356682
18 March 2020
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6923902
12 March 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6925306
10 March 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6924132
17 August 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6785951
17 August 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6789178
19 July 2018
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6484182
14 July 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6478561
11 July 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6475654
24 May 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6418346
19 January 2018
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6340246
27 July 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6222186
17 January 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6071909
18 March 2014
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4818715
7 March 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4808295
Deficiency record · 11
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 November 2025
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.
PSCO observed deteriorated pilot hoses on all of the Co2 cylinders for the engine room.
74 SOLAS II-2/14.1.1
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 27 November 2021
Resolved
To assist in casualty investigations, ships, when engaged on international voyages, subject to the provisions of regulation 1.4, shall be fitted with a Voyage Data Recorder (VDR); the VDR should continuously maintain sequential records of pre-selected data items relating to the status and output of the ship's equipent and command and control of the ship. (74 SOLAS (14) V/20.1)(Resolution A.861 (20))
While on ship's bridge, PSCO observed an error message on the VDR; after restarting the VDR, the error message persisted. Error message said "Communication with the Final Recording MEdium has been lost."
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 24 May 2018
Resolved
01305-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO found printer for Engine Room control log inoperable (Alarm Printer) however, main control computer history is able to demonstrate only one week of alarm history. 74 SOLAS (14) I/11(a) Action Taken 40ac
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 May 2018
Resolved
2. Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO found emergency fuel stop inoperable due to operator error. Rectified on the spot with proper training and signage. 74 SOLAS (14) II-2/14.2.1.2 Action Taken 10c
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 23 January 2018
Resolved
2565 - The Company should establish and maintain procedures to control all documents and data which are relevant to the safety management system. The company should ensure that obsolete documents are properly removed.
Vessel uses software program Shipmanager for SMS documents. Updated to SMS documents are pushed from shore to ship and marked as "not read" within system. After reviewing an updated document, crew must click button in software program acknowledge receipt and review and change status to "read". PSCOs observed that over 50 % of SMS documents showed as "not read". This presents objective evidence that the most current version of documents are not being implemented on board. As an example, upon request the ship's crew presented version 01.01.02 dated 16NOV2015 of Form F01015 (Critical Equipment List). However, per Shipmanager, version 01.01.03 dated 30JUN2016 is the most recent.
Provide documentary evidence that all updates to the SMS have been read onboard and properly implemented.
74 SOLAS 14 IX/3.1 REF ISM 11
15ac
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 23 January 2018
Resolved
2055 - Maintenance, testing, and inspections of firefighting equipment shall be carried out based on guidelines developed by the Organization [MSC Circ 1432] and incorporated into the firefighting maintenance plan.
Ship's firefighting maintenance plan does not substantially correspond with the requirements of MSC Circ 1432 and Antigua and Barbuda (flag state) Circular 2012-011 requirements. For example, items in PMS for monthly tests of fixed CO2 fire extinguishing system do not correspond with requirements, and multiple items for annual testing of main mains/pumps are missing.
Firefighting maintenance plan shall be reviewed and revised as necessary by company in order to correspond with pertinent regulatory requirements.
74 SOLAS 14 II-2/14.2.2
15ac
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 23 January 2018
Resolved
2550 - The inspections mentioned in 10.2 [periodical inspections of equipment] as well as the measures referred to in 10.3 [measures aimed at promoting the reliability of critical equipment] should be integrated into the ship's operational maintenance routine.
The ship's critical equipment list (Form F01015) lists the flexible coupling between the ME and gearbox as a piece of critical equipment, and stipulates that the periodical maintenance required is a monthly visual check. However, this PMS item is only required every 3 months per the vessel's electronic PMS schedule in Shipmanager (task C-003-C-GB). Thus, the two periodicity requirements do not align. Additionally, F01015 lists quick closing valves as critical equipment. However, there are only PMS tasks for FO/DO valves, but none for lube oil, within Shipmanager.
Company shall review critical equipment list and compare against PMS line items in Shipmanager to ensure consistency and verify that periodical maintenance & checks are being conducted.
74 SOLAS 14 IX/3.1 REF ISM 10.4
15ac
Fire Fighting › Automatic Sprinkler System › Stop Valves
Issued 19 January 2018
Resolved
0725 - A ship when in port of another contracting government is subject to control by officers duly authorized by such government concerning operational requirements in respect of safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to safety of ships. Vessel is classed as automated-unmanned machinery space.
The PSCO observed the Minimax hyper mist system discharge outlet valves to be in the manually closed position, rendering the system incapable of fighting a fire in high risk fire areas in the engine room. 74SOLAS(14)XI-1/4.1 and 74SOLAS(14)II-2/2.1.2 30ABC
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 19 January 2018
Resolved
2535-The company should establish procedures to ensure that the ship is maintained in conformity with the provisions if the relevant rules and regulations and with any additional requirements which may be established by the company.
Vessel's crew could not provide PSCOs with company's SMS procedures or manufacturer's instructions (MINIMAX) containing testing, maintenance, or disabling procedures for hyper mist system. Crew did provide PSCO with proof of monthly inspections, however, there were no specific written procedures for testing or inspecting the system. 74SOLAS(14)IX/3.1 ISM Code Part A/10.1 and 74SOLAS(14)II-2/14.2.2.1 30ABC
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 18 March 2014
Resolved
ALL SHIPS OF 500 GT AND UPWARDS SHALL HAVE A GYRO-COMPASS. VESSEL'S GYRO-COMPASS IS INOPERATIVE.SOLAS(09)V/19.2.5.1
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 March 2014
Resolved
9900 - Other - Each xfer pipe system must not leak under static liquid pressure at least 1.5x the max allowable working pressure. Vessel's crew stated that pressure testing of the bunkering lines had never been conducted. Provide proof of satisfactory pressure testing of bunkering lines prior to conducting bunkering operations in U.S. waters. - 33 CFR 156.170
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.