Records from 2016 to 2026. Most recent: inspection, 23 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 15
23 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8329413
2 April 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8090046
2 April 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7887903
19 March 2024
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7838663
9 May 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7676024
22 March 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7389539
2 February 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7389546
12 March 2021
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7155101
13 May 2020
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6927972
28 February 2020
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6917625
8 March 2019
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6638837
3 April 2018
Administrative Inspection · Drydock Exam · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6367500
29 December 2017
Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6339665
24 April 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6121870
11 April 2016
Annual Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5846716
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2025
Resolved
46 CFR 176.810 (a)(1); 705c
At each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment, including the inspection of each portable fire extinguisher to check for excessive corrosion and general condition. MI observed gauge on forward portable extinguisher able to rotate freely rendering gauge in-accurate. Resolve in 7 days.
Action required: 705 - Other - as specified
Due 9 April 2025
Resolved 8 April 2025
Resolution: Reviewed photo of new portable fire extinguisher installed. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 April 2025
Resolved
46 CFR 183.420; 705c
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed STBD running light not operational. Restricted to daytime operations and visibility greater than 1NM.
Action required: 705 - Other - as specified
Due 2 April 2025
Resolved 5 April 2025
Resolution: Received email with photo of STBD Nav light operational. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2022
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. The Certificate of Inspection was not posted.
46CFR176.302 / 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 15 May 2022
Resolution: COI is now posted.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 April 2022
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. The stability letter was not posted.
46 CFR 176.306 / 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 15 May 2022
Resolution: Stability letter is now posted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Attending marine inspector identified unused breakers that were corroded and had dead end wires.
46 CFR 183.200(b) / 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 15 May 2022
Resolution: Crew cleaned and capped electrical conduit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. The fuel shutoff valves' marking was not clearly legible and the direction of operation was not indicated.
46 CFR 185.608 / 16c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2022
Resolved 7 May 2022
Resolution: Crew posted instructions for use for fuel shut-off valves.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 April 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens and must consist of a single screen of corrosion resistant wire of at least 30x30 mesh. The STBD side outboard engine's fuel tank vent did not meet 30x30 mesh wire requirement.
46 CFR 182.450(e) / 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 5 May 2022
Resolution: Vessel replaced fuel tank vent screens with screens IAW the present regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2022
Resolved
At least one ring life buoy must be fitted with a lifeline at least 60 ft in length, non-kinking, at least a diameter of 5/16'', and dark in color if synthetic, or of a type certified to be resistant to deterioration from UV light. Vessel's life line was approximately 45'.
46CFR180.70(c) / 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 30 April 2022
Resolution: Vessel Rep purchased new line for life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket was taken out of service and one life jacket was missing. Passenger count is reduced to 38 passengers until deficiency is rectified.
46CFR180.71(a) / 705c
Action required: 705 - Other - as specified
Resolved 30 April 2022
Resolution: Vessel purchased two approved adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
10 wasted life jackets found.
Total persons on board limited to thirty-two (32)
IAW: 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 10 June 2020
Resolution: Verified O/O replaced 10 life jackets. Vessel's total persons allowed on board restored to 42.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: Current tables.
Vessel did not have up to date copy of Current Tables.
Provide up to date copy of Current Table on board.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 13 May 2019
Resolution: Vessel provided current tables on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 April 2019
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Fuel supply hoses on port and starboard fuel tanks are in state of decay and must be replaced.
Replace fuel hose with Coast Guard approved non-metallic flexible fuel hose. SAE J-1527, USCG Type A1.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 13 May 2019
Resolution: New CG approved fuel hoses installed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 April 2018
Resolved
Apply name and hailing port to stern of vessel. 46 CFR 67.15-3(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Operator applied name and hailing port to stern.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 April 2018
Resolved
Provide proof of EAP training. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Operator provided proof that employees have received EAP training.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 April 2018
Resolved
Provide proof that employees have read and signed company drug testing policy. 46 CFR 16.203
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Verified employees have read and signed company drug testing policy.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 April 2018
Resolved
Replace expired alcohol testing devices onboard vessel. 46 CFR 16.203
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2018
Resolution: Verified operator has replaced expired testing devices.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 26 April 2017
Resolved
Deck rail cracked, repair to the satisfaction of the marine inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 4 May 2017
Resolution: Deficiency corrected to the satisfaction of the attending Marine Inspector.
Engineering › Fuel Oil Service System › Hose
Issued 3 May 2016
Resolved
Fuel lines not equipped with double hose clamp. Install second hose clamp IAW 46 CFR 182.410(d)
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 3 June 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 May 2016
Resolved
Provide second form of navigation charts and updated tide tables IAW 46 CFR 184.410(d)
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 3 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2016
Resolved
Provide ammonia inhalants and unexpired burn gel IAW 46 184.710
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 May 2016
Resolved
Label lifejacket quantity IAW 46 CFR 185.604(f)
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 3 June 2016
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 3 May 2016
Resolved
Obtain current employee list and MIS report for DAPI compliance IAW 46 CFR 4.06
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 3 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2016
Resolved
Captain must obtain Marine Radio Operator permit. Vessel is restricted to 1000 ft from shore IAW 47 CFR 13
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Construction/Loadline › Hull › Hull Plating
Issued 11 April 2016
Resolved
4 Cracks under deck: at second weld seam on STBD & Port hull, at fourth weld seam on STBD hull, and sixth weld seam on STBD hull.
Due 2 May 2016
Resolved 3 May 2016
Construction/Loadline › Structures › Deck Plating
Issued 11 April 2016
Resolved
Crack in fwd corner on the STB side of the fwd platform.
Due 2 May 2016
Resolved 3 May 2016
Construction/Loadline › Structures › Door
Issued 11 April 2016
Resolved
Support for aft end of the STBD access point cracked at the deck.
Due 2 May 2016
Resolved 3 May 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 April 2016
Resolved
Owner must submit a plan for beaching operations.
Due 2 May 2016
Resolved 3 May 2016