MAURY USCG vessel records Sign in
← All vessels

GREEN KNIGHT

GREEN KNIGHT is a 1973 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1990, most recently in December 2025, along with 78 deficiencies.

Records from 1990 to 2025. Most recent: inspection, 22 December 2025.

Built
1973
Last inspected
22 December 2025
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ7504
121080
Flag
UNITED STATES
368007340
Maury page id
psix-121080

Inspections, by type

…with no type recorded19
Years with a record 30 calendar years (1990–2025)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)97.0 ft × 25.0 ft × 2.8 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS · HOUMA, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 19 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7504MMSI 368007340 · active · compulsorily equipped · granted 22 September 2017, expires 22 September 2027
WDE8716MMSI 367408670 · expired · compulsorily equipped · granted 8 May 2009, cancelled 13 July 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDA9863MMSI 369102000 · cancelled · compulsorily equipped · granted 26 September 2002, cancelled 23 July 2012 · licensed under a name not among this hull’s recorded names (not shown)
WCY8473MMSI not assigned · expired · voluntarily equipped · granted 21 January 1999, cancelled 28 March 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEABULK ST MARTIN Passenger (Uninspected) · MISLE 407004 · 1 August 2001 · activity 172904DONNY JR Passenger (Inspected) · MISLE 52807 · 23 January 1996 · activity 183255

Inspection history · 68

22 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8286565
16 December 2025 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8284262
5 November 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8029875
16 October 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8015488
4 September 2024 Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8004076
23 January 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7853414
21 September 2022 COI Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7563634
14 September 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7570843
13 May 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7452069
7 December 2021 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7364194
26 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7183145
2 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7104903
27 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7085059
4 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7060138
19 December 2019 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6876984
12 November 2019 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6852043
25 October 2018 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6567885
26 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6361776
16 August 2017 COI Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6242834
17 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6212148
26 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132904
6 May 2014 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4851113
8 February 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4240884
4 February 2011 Internal Structural Exam · Drydock Exam · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3942350
26 February 2010 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3686391
5 February 2009 Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3470194
26 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3369996
1 April 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3188992
16 April 2007 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2911880
14 September 2006 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2778103
26 January 2006 Hull Examination · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2573158
20 January 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2278194
15 December 2003 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1964187
24 January 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1734777
14 November 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418995
1 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 172904
17 January 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391459
15 February 2000 Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437672
4 February 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416848
4 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807017
23 December 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 443968
18 November 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470703
22 July 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780564
12 June 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455493
16 January 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433138
14 January 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 532646
20 July 1996 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 514462
3 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 484400
30 May 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 161569
13 March 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 885820
24 January 1996 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385627
23 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 183255
16 November 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414532
13 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 375262
2 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 86195
2 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665753
21 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665754
20 October 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866365
17 October 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358564
2 July 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 211890
2 February 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 851735
7 January 1994 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448496
27 December 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 116266
2 November 1993 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362873
11 August 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 527966
12 November 1992 Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 827439
24 October 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940722
31 October 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238356

Deficiency record · 78

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2024 Resolved
Each ring life buoy on a vessel must Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150; Port life ring was not serviceable and all other life rings need to be clearly marked.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 5 November 2024
Resolution: Vessel rep submitted photos of deficiency corrected
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Steam pipes, pressure pipes, wires (insulation)
Issued 5 November 2024 Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. exhaust lagging in various areas of the engine room insufficient or missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2024
Resolved 5 November 2024
Resolution: Vessel rep submitted photos of deficiency corrected
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2024 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Marine Inspectors observed the vessel's life floats stowed directly beneath the ensign line and navigation lights stack. The lights stack has a protruding welded attachment blocking the survival craft's float free path. Ensure survival craft can float free.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2024
Resolved 29 January 2024
Resolution: Vessel representative provided photographic evidence that they had removed the yard arm obstruction.
Engineering › Bilge Water Management System › Piping
Issued 7 May 2014 Resolved
Renew wasted pipe on bilge overboard in E/R, fwd stbd corner. Duriong hydrostatic tes at 150 psi of fire main and emergency fire main, which is the bilge piping, pin hole leaks were seen spraying at threaded connection to elbow.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2014
Resolution: Recieved picture of sat repair and statement from vsl rep of pressure test.
Fire Fighting › Fire Main › Condition
Issued 6 May 2014 Resolved
Repair wasted firemain, stbd side on deck. Pipe blew out a 1/8in size hole during fire drill. Vessel to renew with new pipe and conduct hydrostatic test of entire fire main.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2014
Resolution: Witnessed sat hydrostatic test at 150 psi of fire main and emergenct firemain off potable water pump.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 May 2014 Resolved
Provide lifejacket plcard for all tyoes of life preserves used on-board.
Action required: 705 - Other - as specified
Resolved 7 May 2014
Lifesaving › Lifefloat › Float-free Link
Issued 6 May 2014 Resolved
Provide float-free link for lifefloats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2014
Fire Fighting › Fire Hydrants › Location/Position
Issued 6 May 2014 Resolved
Provide spanner wrnech for each fire station.
Action required: 705 - Other - as specified
Resolved 7 May 2014
Engineering › Pressure Vessel › Relief Valve
Issued 6 May 2014 Resolved
Provide operable relief valves for pressure vessels that have been bench tested.
Action required: 705 - Other - as specified
Resolved 7 May 2014
Fire Fighting › Means of Escape › Blocked
Issued 6 May 2014 Resolved
Secure washer/dryer from shifting.
Action required: 705 - Other - as specified
Resolved 7 May 2014
Lifesaving › Lifefloat › Float-free Link
Issued 1 April 2008 Resolved
Unidentifiable.
Due 8 April 2008
Resolved 7 April 2008
Resolution: Received faxed invoice and Statement from the vessel''s master that a new float-free link was purchased and installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 April 2008 Resolved
Noted washer discharge plumed into vessel's engine room center line bilge which contained oil residue. Although records indicated that bilges are emptied by truck to a reception facility IAW 33 CFR 155.350, attending vessel rep agreed to redirect washer piping to avoid any accidental overboard oil discharge. Attending MI should verify compliance with 155.350 at the next inspection.
Due 19 December 2008
Resolved 7 May 2009
Resolution: Sump installed for washing machine in engine room.
Documentation › Markings/Placards › Warning Signs
Issued 21 September 2006 Resolved
Post emergency broadcast placard
Due 21 October 2006
Resolved 24 November 2006
Lifesaving › Lifefloat › Paddle
Issued 21 September 2006 Resolved
Lash paddles to lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 21 September 2006 Resolved
Not rescue boat - rescue platform: Renew rescue platform to proper height for vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 September 2006 Resolved
Renew expired items in first aid kit.
Due 21 October 2006
Resolved 24 November 2006
Fire Fighting › Grease Extraction Hood › General
Issued 21 September 2006 Resolved
Clean grease from range hood.
Due 21 October 2006
Resolved 24 November 2006
Construction/Loadline › Structures › Deck Plating
Issued 21 September 2006 Resolved
Renew ladder rungs on ladder from main deck to top of pilot house on port side.
Due 21 October 2006
Resolved 24 November 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 September 2006 Resolved
Install deck rails at proper height around plexiglass deck fitting on top of pilot house next to control station.
Due 21 October 2006
Resolved 24 November 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 September 2006 Resolved
Install guard around port stack on pilot house to protect members using ladder.
Due 21 October 2006
Resolved 24 November 2006
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 September 2006 Resolved
Tighten port shaft packing to reduce excessive leak.
Due 21 October 2006
Resolved 24 November 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 21 September 2006 Resolved
Renew hole in bulkhead behind emergency blower shutoff at enterence to engine room.
Due 31 December 2006
Resolved 24 November 2006
Electrical › Electric Supply System (service) › Cable
Issued 21 September 2006 Resolved
Replace engine room plastic wire tie supports with metal supports.
Due 21 October 2006
Resolved 27 November 2006
Engineering › Bilge Water Management System › Hose
Issued 21 September 2006 Resolved
Double clamp all flex hose connections on vital systems.
Due 21 October 2006
Resolved 24 November 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 September 2006 Resolved
Clean oil off of engine room overhead and monitor both for any signs of exhaust leak.
Due 21 October 2006
Resolved 24 November 2006
Construction/Loadline › Structures › Deck Plating
Issued 21 September 2006 Resolved
Renew deck temp repair on main deck and make repairs available for inspcetion by OCMI.
Due 31 December 2006
Resolved 24 November 2006
Communications › Radio Communications › EPIRB
Issued 14 September 2006 Resolved
Renew EPIRB antenna
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2006
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 September 2006 Resolved
Complete and log all lifesaving equipment safety checks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2006
Engineering › Steering Gear System › Rudder
Issued 14 September 2006 Resolved
Ensure rudders are in proper working order and make available for inspection to marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 14 September 2006 Resolved
Renew high water alarm in steering compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2006 Resolved
Submit proposal to OCMI to repair improper deck patch over port and stbd MDE's.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2006 Resolved
Renew missing plexi glass & structural member on top of pilot house.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2006 Resolved
Renew steps on ladder leading from main deck to engine room.
Action required: 705 - Other - as specified
Due 21 November 2006
Resolved 24 November 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 September 2006 Resolved
Renew longitudinal frame in rudder room fwd of stbd rudder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Navigation › Piloting/Steering › Marine Charts
Issued 14 September 2006 Resolved
Obtain corrected charts for area transitted.
Due 21 October 2006
Resolved 24 November 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 September 2006 Resolved
Fax proof of drug consortium enrollment to marine inspector.
Due 21 October 2006
Resolved 24 November 2006
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 14 September 2006 Resolved
Write fuel transfer proceedures IAW 33 CFR 155.720 &.750
Action required: 703 - Prior to bunkering operations
Due 21 October 2006
Resolved 24 November 2006
Communications › Public Address System › Loudspeaker
Issued 14 September 2006 Resolved
Install new public address loudspeaker in passenger general area.
Due 21 October 2006
Resolved 24 November 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 13 September 2006 Resolved
repack rudder bearing to stop flooding.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2006
Lifesaving › Lifefloat › Float Free
Issued 13 September 2006 Resolved
Restow lifefloats without gear on top of them so they can float free.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2006
Resolved 14 October 2006
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 13 September 2006 Resolved
Repair port MDE to prevent heavy oil leaks on outboard side.
Due 27 September 2006
Resolved 24 November 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 September 2006 Resolved
check emergency lighting and renew batteries as needed.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2006
Resolved 22 November 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 September 2006 Resolved
Renew bilge alarm light on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2006
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 19 December 2003 Resolved
Provide Local Notice to Mariners.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2004
Resolved 20 December 2003
Documentation › Certificates/Documents
Issued 19 December 2003 Resolved
Provide Bridge-to-Bridge Certificate. LEGACY COMPONENT DESC: Bridge to Bridge Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2003
Communications › Radio Communications › VHF Radiotelephone
Issued 19 December 2003 Resolved
Replace antenna for VHF-FM radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2003
Construction/Loadline › Structures › Door
Issued 19 December 2003 Resolved
Make repairs to main deck and engine room watertight doors to properly seal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2003
Construction/Loadline › Structures › Door
Issued 19 December 2003 Resolved
Adjust and provide dogging wrench for engine room emergency escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 December 2003 Resolved
Make repairs to anchor light to operate properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2003
Electrical › Electrical Distribution System (service)
Issued 19 December 2003 Resolved
Provide safety blank for pilothouse electrical panel. LEGACY COMPONENT DESC: Panel board
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 20 December 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 19 December 2003 Resolved
Provide flame screen for sewage vent. LEGACY COMPONENT DESC: Flame Screens
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 20 December 2003
Lifesaving › Lifebuoys
Issued 19 December 2003 Resolved
Stencil vessel name and homeport on all lifebuoys. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 20 December 2003
Engineering › Fuel Oil Service System › Hose
Issued 19 December 2003 Resolved
Renew all flexible hoses as marked on main engines and generators.
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 11 January 2004
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 19 December 2003 Resolved
Rewire stbd main engine tachometer unit.
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 6 January 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 December 2003 Resolved
Make repairs to stbd main engine exhaust flex pipe. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 20 December 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 19 December 2003 Resolved
Provide vent duct for dryer.
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 31 December 2003
Communications › Radio Communications › EPIRB
Issued 19 December 2003 Resolved
Renew EPIRB antenna.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2003
Deck/Cargo › Holds/Tanks
Issued 15 December 2003 Resolved
Provide protective guards for fuel tank sight glass. LEGACY COMPONENT DESC: Liquid Level Gauging
Action required: 705 - Other - as specified
Due 19 January 2004
Resolved 31 December 2003
Construction/Loadline
Issued 17 January 2001 Resolved
PROVIDE PROOF OF PRIOR CG APPROVED PLAN REVIEW.
Condition: Unknown
Due 17 January 2001
Resolved 17 January 2001
Fire Fighting
Issued 12 June 1997 Resolved
SERVICE FIRE EXTINGUISHER STBD SIDE ENG ROOM._x001C_
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Electrical
Issued 12 June 1997 Resolved
REMOVE/REPLACE PLASTIC WIRE TIES THROUGHOUT VSL WITH PROPER METAL FASTENERS.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
MOUNT SEWAGE PUMP SHAFT GUARD.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 12 June 1997 Resolved
REMOVE/PROPERLY INSTALL WELDING LEADS.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Electrical
Issued 12 June 1997 Resolved
REMOVE DEAD END WIRES IN WHEELHOUSE.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Electrical
Issued 12 June 1997 Resolved
REPAIR/REPLACE LIGHT GLOBES IN ENG ROOM (GLASS MISSING).
Condition: Unknown
Due 30 June 1997
Resolved 3 July 1997
Lifesaving
Issued 12 June 1997 Resolved
REPLACE 2 WATERLIGHTS TO LIFE FLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 June 1997
Resolved 3 July 1997
Fire Fighting
Issued 12 June 1997 Resolved
REPAIR/REPLACE SYBD MAIN DECK FIRE NOZZLE, PRIOR TO SAILING.
Condition: Unknown
Due 13 June 1997
Resolved 16 June 1997
Engineering
Issued 12 June 1997 Resolved
PROVIDE PROPER HOSE CLAMPS FOR PORT MAIN ENGINE.
Condition: Unknown
Due 30 June 1997
Resolved 3 July 1997
Engineering
Issued 12 June 1997 Resolved
REPAIR PACKING GLAND STBD SHAFT (SHAFT LEAKS).
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
PROVIDE PERM. MOUNTING FOR CLOTHES DRYER.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Electrical
Issued 12 June 1997 Resolved
INSTALL BLANKS IN ENG ROOM POWER PANELS.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
REPLACE MISSING HOT WATER HEATER PLATE.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
REMOVE/PROPERLY INSTALL PRESSURE TANK TIED TO HOT WATER HEATER.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Construction/Loadline
Issued 24 January 1996 Resolved
Make permanent repairs to damage in way of bow stem.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Documentation
Issued 2 November 1993 Resolved
PROVIDE COPY OF VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Accommodation/Occupational Safety
Issued 2 November 1993 Resolved
RELOCATE EMERGENCY STOVE DISCONNECT TO A REMOTE LOCATION.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Engineering
Issued 12 November 1992 Resolved
DOUBLE NUT ALL SHAFT PACKING BOLTS.
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Construction/Loadline
Issued 12 November 1992 Resolved
WILD CRACK IN AFT BULK HEAD IN RUDDER COMP. AMIDSHIP AT DECK.
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.