Records from 2016 to 2017. Most recent: inspection, 30 November 2017.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 August 2016
Resolved
Pre-engineered fixed gas fire extinguisher system must be service annual as required by 46 CFR 176.810 & NFPA 17. Provide proof of annual service on FGFE.
Due 29 August 2016
Resolved 19 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 9 August 2016
Resolved
Engine turbo located next to FGFE heat sensor and must be insulated as required by 46 CFR 176.830. Insulate engine turbo to prevent accidental discharge of FGFE.
Due 29 August 2016
Resolved 19 August 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 August 2016
Resolved
All cables and wires must be installed with metal supports spacer of not more than 24 inches apart as required by 46 CFGR 183.340. Install wire support through out the vessel.
Due 29 August 2016
Resolved 19 August 2016
Engineering › Steering Gear System › Hand Pump
Issued 9 August 2016
Resolved
Vessel must be provided with an auxiliary means of steering as required by 46 CFR 182.620. Show proper operation of the auxiliary steering.
Due 29 August 2016
Resolved 26 August 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 August 2016
Resolved
Show proper operations on installed Higgins bilge pumps as required by 46 CFR 182.520.
Due 29 August 2016
Resolved 26 August 2016
Stability › Unintentional Flooding › General
Issued 9 August 2016
Resolved
Replace rusted fasteners on rudder post seal to prevent hazardous condition as required by 46 CFR 176.830.
Due 29 August 2016
Resolved 26 August 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 August 2016
Resolved
Flexible hose designed for use of hose clamps must have two clamps at both end as required by 46 CFR 182.720. Install hose clamps in all identified hoses missing clamps.
Due 29 August 2016
Resolved 19 August 2016
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 9 August 2016
Resolved
Chemical testing of master and crew must be conducted as required by 46 CFR16.201. Provide proof of pre-employment drug testing, randomly tested, DER & Company policy signed by each crew,
Due 31 August 2016
Resolved 30 August 2016
Documentation › Certificates/Documents › Stability Letter
Issued 9 August 2016
Resolved
Vessel must have stability letter as required by 46 CFR 178.230. Issued new stability letter with vessel current name.
Due 31 August 2016
Resolved 30 August 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 August 2016
Resolved
Provide proof of COD or CNMI registry as required by 46 CFR 67.161.
Due 10 September 2016
Resolved 15 December 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 August 2016
Resolved
Crew training shall be logged or documented for review by the Coast Guard when requested as required by 46 CFR 185.420. Provide proof of quarterly training conducted by the crew.
Due 31 August 2016
Resolved 22 August 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 9 August 2016
Resolved
Emergency instructions must be mounted at the operating station as required by 46 CFR 185.510
Due 31 August 2016
Resolved 22 August 2016
Operations/Management › Passenger Operations › Safety Orientation
Issued 9 August 2016
Resolved
Master shall ensure suitable public announcements are made informing all passenger of vessel safeties as required by 46 CFR 185.506. Update current safety orientation to reflects on new routs and vessel safeties.
Due 31 August 2016
Resolved 26 August 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 August 2016
Resolved
Vessel must carry adequate and up-to-date charts, CG light list, U.S. Coast Pilot, tide table & current table as required by 46 CFR 184.420.
Due 31 August 2016
Resolved 22 August 2016
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 9 August 2016
Resolved
The name of the vessel must be marked or painted in clearly legible letters and numbers as required by 46 CFR 185.604. Marked all unmarked child lifejackets
Due 31 August 2016
Resolved 22 August 2016
Fire Fighting › Fire Bucket › Availability
Issued 9 August 2016
Resolved
Vessel not required to have power driven fire pump must have at least three 2.5 gallons fire buckets as required by 46 CFR 181.610. Provide three fire buckets marked with " FIRE BUCKETS".
Due 31 August 2016
Resolved 22 August 2016