MAURY USCG vessel records
← All vessels

MR. JAKE

MR. JAKE is a 2013 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in March 2026, along with 9 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 17 March 2026.

Built
2013
Last inspected
17 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG6890
1212174
Flag
UNITED STATES
Maury page id
psix-1212174

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)174.4 ft × 32.0 ft × 14.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)174.4 ft × 32.0 ft × 14.0 ft
ITC tonnagegross 491 / net 147
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 2013
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
491 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
147 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

17 March 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8305896
28 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8121300
2 April 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8103791
16 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7895736
1 March 2023 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7643715
25 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7458840
4 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7188758
22 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7180406
11 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110156
23 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6984393
1 April 2020 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6934045
24 September 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6845863
31 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6699135
31 May 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6741544
7 May 2019 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678923
10 April 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6388403
3 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6137483
26 April 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6134061
21 June 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5923936

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 April 2025 Resolved
The following items are worklist items to be corrected prior to receiving drydock or internal structure exam credit: 1. Forward ballast tank has excessive pitting and corrosion in the aft of the first baffle, extending from the bilge strake to the third longitudinal member from strake. Complete repairs and conduct non-destructive testing in the presence of USCG Inspectors. 2. Port potable water tank, in the 4th void aft, broken welds in bulkheads 3 and 4 on the third longitudinal frame from the keel need to be repaired. 3.#4 MDE exhaust holding bracket weld is cracked, requires repairs. 4. #3 MDE exhaust support at end of pipe is cracked, requires repairs. 5. #3 MDE exhaust holding bracket is missing bolt to support exhaust pipe, needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 May 2025
Resolved 17 April 2025
Resolution: Verified repairs done to all worklist items. Conducted air testing of inserts on port and stbd sideshell just aft of the bowthrusters; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2024 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be water jacketed or effectively insulated and protected. Main diesel raw water outlet leaks. 46 CFR 182.425(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 28 June 2024
Resolution: All four MDE raw water outlets rewelded to satisfaction of CG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 April 2024 Resolved
A vessel must comply with the structural design requirements of the standard hull material of the vessel. Cracked welds in the oil room vent compartments. 46 CFR 177.300
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 28 June 2024
Resolution: Vents in oil room compartment rewelded to the satisfaction of CG.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 April 2023 Resolved
Vessels that operate on a Coastwise or Oceans route must conduct emergency egress training for each member of the crew at least monthly and each time a new crew member joins such vessel. This training must be completed and logged in accordance with CG regulations. - 46 CFR 185.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2023
Resolved 5 April 2023
Resolution: Vessel Rep. provided documentation that the vessel conducted an egress drill/training for the crew and logged it.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 April 2023 Resolved
A vessel shall be ready for inspections of the hull structure and its appurtenances including all weathertight closures above the weather deck. Weathertight gasket of hatch leading to or from the passenger area is worn and must be replaced. - 46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2023
Resolved 6 April 2023
Resolution: Photo documentation was provided to show that the weathertight gasket to the escape hatch in forward passenger area was replaced to the satisfaction of a USCG Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 21 June 2016 Resolved
#4 MDE could not be started due to issue with electronics package.
Due 21 June 2016
Resolved 21 June 2016
Resolution: corrected prior to departure of CGMI.
Navigation › Piloting/Steering › Marine Charts
Issued 21 June 2016 Resolved
marine charts were out of date and vessel did not have a chart correction kit onboard. required vessel rep to provide up to date charts and a means to make corrections.
Due 29 June 2016
Resolved 29 June 2016
Resolution: vessel rep provided chart correction kit and up to date marine charts.
Engineering › Pressure Vessel › Pressure Gauge
Issued 21 June 2016 Resolved
pressure gauges did not show required range. required vessel rep to provide gauge going from 0 to 1.2 to 2.0 times the relief vavle pressure.
Due 29 June 2016
Resolved 29 June 2016
Resolution: vessel rep provided current gauges.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 21 June 2016 Resolved
transfer procedures did not have sufficent contents as per 33CFR155. required vessel rep to add vessel specific informaiton to the transfer procedures.
Due 5 July 2016
Resolved 7 July 2016
Resolution: vessel rep provided sufficent vessel specific directions for diffrent transfers.

Ownership record