← All vessels
TRANSBALTIC
TRANSBALTIC is a 2012 freight ship. The Coast Guard has recorded 23 inspections since 2015, most recently in May 2026, along with 9 deficiencies — 1 with no resolution recorded — and 8 operational controls.
Records from 2015 to 2026. Most recent: inspection, 12 May 2026.
- Built
- 2012
- Last inspected
- 12 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9595151 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8MC8
1212356
Flag
PANAMA
—
Maury page id
psix-1212356
Inspections, by type
…with no type recorded7
…past their stated due date1
Years with a record
9 calendar years (2015–2026)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23790 - Convention (Subpart B), Gross Ton
36699 - Dead Weight, Metric Ton
46064 - Displacement, Metric Ton
11229 - Convention (Subpart B), Net Ton
36699 - Dead Weight, Metric Ton
46064 - Displacement, Metric Ton
11229 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
12 May 2026
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8368165
13 December 2025
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8283554
16 June 2025
PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8158841
13 June 2025
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8158567
5 June 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8152886
31 January 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8073035
26 January 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8064589
19 January 2025
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8066769
28 February 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7873961
22 February 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7868781
22 February 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7868954
18 November 2022
PSC B
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7595090
17 November 2022
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7596249
20 October 2021
PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7336179
26 November 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6863093
15 November 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6855545
7 June 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6701858
9 February 2018
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6352515
8 February 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6352126
8 February 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6352408
5 February 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6352415
6 June 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6154529
8 September 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5238312
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 May 2026
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500l and above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which the tanks are situated. PSCO identified a blocked boiler quick closing valve. Crew removed the block and tested valve satisfactorily. SOLAS 74 II-2/4.2.2.3.4, Deficiency rectified Code 10c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 May 2026
No resolution recorded
The safety management system shall be maintained in accordance with the provisions of the ISM code the company should establish procedures for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. Deficiency #01 provides objective evidence of key shipboards operations not being carried out properly. Provide an internal ISM audit within 90 days to the satisfaction of the OCMI/RO. 74 SOLAS IX/5, ISM Code 7, AC
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 7 June 2019
Resolved
08104 - Alarms - Hydraulic power-operated steering gear shall be provided with the following: a low-level audible and visual alarm shall be given on navigation bridge. PSCO's witnessed audible and visual alarms were not present on navigation bridge for low-level alarm of pump #1.
74SOLAS14CONSCHII-1/Reg 29.12.2
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 June 2019
Resolved
11108 - Life Saving Appliances - Every liferaft shall be stowed with its painter permanently attached to the ship. PSCO's witnessed painter line not fixed to vessel.
74SOLAS14CONSCHIII/Reg 13.4.1
Operations/Management › Casualty Reporting/Post-Casualty Actions › Rendering Necessary Assistance
Issued 8 February 2018
Resolved
If the vessel's radr stops operating properly, the person directing the movement of the vessel must report or cause to be reported to the nearest captain of the port as soon as possible. An inoperable radar was not reported until afte rthe vessel had entered and transitted the port of Hampton Roads. 33CFR 164.53(b)
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 8 September 2015
Resolved
0635-Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. During annual rescue boat servicing, it was identified that the rescue boat davit launching system has a drop in the accumulator system from 110-100 Bar to 60 Bar, potentially slowing the launch and recovery time during an emergency. III/20.2-17abc
Operations/Management › Ballast Water Managment › Sediments
Issued 8 September 2015
Resolved
9900-Ballast Water Management Plan must include detailed fouling maintenance and sediment removal procedures. No logs or records were found as per BWM plan. 33CFR151.2050(g)(3) - MEPC 207(62) - (40c)
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 September 2015
Resolved
0999-Doors required to be self-closing shall not be fitted with hold back hooks. Eight doors were identified as self-closing on the Fire Control Plan that have hold back devices. 74SOLAS(14)II-2/9.4.2.2 (10c)
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 8 September 2015
Resolved
2120-Every ship of 400GT shall carry a garbage management plan which the crew shall follow. Chief mate needs better training as per plan. MARPOL AX.V/Reg.9.2 (10c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.