Records from 2016 to 2021. Most recent: inspection, 11 February 2021.
Inspection history · 7
11 February 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7132601
8 June 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6979887
18 March 2020
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6928438
9 July 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6713806
26 April 2018
Internal Structural Exam · COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6399758
23 May 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6155123
31 March 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5892290
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 June 2020
Resolved
Provide charts, coast pilot, light list and tide tables for intended route.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2020
Resolved 11 June 2020
Resolution: O/O purchased all required documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 June 2020
Resolved
Interlock blower with engine start to provide operation of blower 30 seconds prior to engine start.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2020
Resolved 11 June 2020
Resolution: Owner wired engine starter so that blower has to be on prior to starting engine.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 June 2020
Resolved
Provide maintenance manual for flammable vapor detection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2020
Resolved 10 August 2020
Resolution: Owner emailed copy of flammable vapor detection maintenance manual.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 July 2019
Resolved
When the flexible fuel fill pipe section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling fuel. The portion of the fill pipe which is non-metallic is not connected with a bonding wire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2019
Resolved 16 August 2019
Resolution: item cleared
Communications › Alarms/Indicators › General Alarm
Issued 23 May 2017
Resolved
Operator could not verify the proper operation of the vapor detection system in the engine/fuel space.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 31 May 2017
Resolution: New vapor detection sensor was installed and operational test was completed.
Fire Fighting › Ventilation Systems › Ducts
Issued 23 May 2017
Resolved
The mechanical exhaust in the gasoline fuel space did not have duct work extending to the lower portion of the bilge.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 31 May 2017
Resolution: Operator installed ducts to meet the regulations.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2017
Resolved
Battery was dead in the waterlight attached to the ring life buoy.
Due 23 June 2017
Resolved 31 May 2017
Resolution: Battery was replaced.