VECTIS PRIDE is a 2012 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in October 2025, along with 6 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 6 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it7227 - Convention (Subpart B), Gross Ton 3494 - Convention (Subpart B), Net Ton 11183 - Dead Weight, Metric Ton 14907 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
6 October 2025PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8242693
31 July 2024Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7971664
5 May 2023Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7681575
10 March 2023PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7645573
5 March 2023Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7645657
17 March 2022Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7413600
6 April 2021Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7169431
6 December 2020Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7107208
29 May 2020Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6961051
3 February 2020PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6895366
13 November 2017Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6306108
20 October 2017PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2023Resolved
74SOLAS20 II-1/3-1
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH HAS BEEN RECOGNIZED BY THE ADMINISTRATION
PSCO OBSERVED UNAPPROVED CONNECTION (ELECTRICAL) WITH THE TURBO CHARGER FAN AIR TEMP SENSOR
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 July 2024
Resolution: recieved class report
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 February 2020Resolved
11104 - Rescue boats - Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. During examination of rescue boat port state control officer found crew was unable to start rescue boat engine. 74 SOLAS (14) III/20.2
Action required: 10 - Deficiency Rectified
Due 3 February 2020
Resolved 3 February 2020
Resolution: Deficiency corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2020Resolved
07199 - Other (fie safety) - Waste receptacles shall be constructed of non-combustible materials. Port state control officer found four plastic waste receptacles in use on boat deck. 74 SOLAS (14) II-2/4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2020
Resolution: PSC NOLA received 03 pictures from the master of metal garbage pins rectifying the deficiency.
1099-Internal combustion engines of 2250kW & above or having cylinders of more than 300mm bore shall be provided with a crankcase oil mist detector or engine bearing temperature monitors or equivalent devices. PSCO noted that the oil mist detector was inoperable. 74 SOLAS (14 CONS) II-1/47.2 Code: 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 February 2016
Resolved 22 October 2017
Resolution: Verified onboard that oil mist detector was operable.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 4 January 2016Resolved
1099- An alarm system complying with Regulation 51 shall be provided for all important pressures,temperatures,liquid levels, and other essential parameters. PSCO noted that the cooling water low level alarm was inoperable to the NO.1 Ship Service Generator prime mover. 74 SOLAS (14 CONS) II-I/53.4.3 Code: 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 February 2016
Resolved 22 October 2017
Resolution: Verified onboard that cooling water low level alarm was operable.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 4 January 2016Resolved
0999-Each vessel must have oxygen analysis and gas detection equipment that is calibrated in accordance with its manufacturers instructions. PSCO noted vessel is not fitted with span gas to accomplish required calibration. 74 SOLAS (14 CONS) VI/3 & 46 CFR 148.420 Code 40ac
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 February 2016
Resolved 22 October 2017
Resolution: Verified span gas was onboard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.