← All vessels
MAGIC VICTORIA
MAGIC VICTORIA is a 2012 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in November 2025, along with 3 deficiencies.
Records from 2016 to 2025. Most recent: inspection, 20 November 2025.
- Built
- 2012
- Last inspected
- 20 November 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9608867
V7YS4
1215013
Flag
MARSHALL ISLANDS
Maury page id
psix-1215013
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it40976 - Convention (Subpart B), Gross Ton
22544 - Convention (Subpart B), Net Ton
74902 - Dead Weight, Ton
88745 - Displacement, Ton
22544 - Convention (Subpart B), Net Ton
74902 - Dead Weight, Ton
88745 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
20 November 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8271567
6 November 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8265000
16 March 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8094541
21 February 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8082467
26 January 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8069913
29 May 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7922293
20 May 2024
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7915406
18 September 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7561195
2 September 2022
COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7549406
10 September 2018
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6537385
9 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6536257
21 July 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6481035
28 March 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5833053
Deficiency record · 3
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 November 2025
Resolved
The fixed fire detection and fire alrm system required in paragraph 4.1.1 shall be so designed and the detectors so positioned as to detect rapidly the onset of fire in any part of the spaces and under any normal conditions of operation fo the machinery and variations of ventilation as required by the possible range of ambient temperatures. PSCO observed flame detectors requiring modication in order to operate effectively.
74 SOLAS (09) II-2 / 7.4.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 November 2025
Resolved
The follwoing fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs:...fire detection and fire alarm systems. PSCO observed two inoperable flame detectors near the generator.
74 SOLAS (09) II-2 / 14.2.1.1.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 May 2024
Resolved
After any survey of the ship under paragraph 1 of this regulation has been completed, no changes shall be made in the structure, equipment, systems, fittings, arrangements of material covered by the survey, without the sanction of the administartion, except the direct replacement of such equipment and fitting. Vessel reported on NOA of temporary repairs to HFO and MGO bunkering line. Vessel is required to provide class report attesting to repairs prior to bunkering operations.
MARPOL I/6.4.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.