CAPE TOWN HIGHWAY is a 2010 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in July 2024, along with 2 deficiencies — 1 with no resolution recorded —.
Records from 2016 to 2024. Most recent: inspection, 22 July 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it58535 - Convention (Subpart B), Gross Ton 21676 - Dead Weight, Ton 17561 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 9
22 July 2024Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7964501
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2023No resolution recorded
Where cables which are installed in hazardous areas introduce the risk of fire in the event of an electrical fault in such areas, special precautions shall be taken to the satisfaction of the administration.
Wiring was exposed in the vessel's purifier room as well as a leak from main F/O Heater tank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2023 — due date passed with no resolution recorded
14 - Pollution Prevention › 148 - Ballast Water › Ballast water logs/records
Issued 11 February 2023Resolved
Requests for approval of BWMS must be submitted to the marine safety center.
Vessel does not have the signed copy of the USCG Ballast Water Treatment System approval letter.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 July 2024
Resolution: RECIEVED APPROVAL LETTER
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.