Records from 2000 to 2008. Most recent: inspection, 28 October 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 October 2008
Resolved
Replace/repair retro-reflective tape on (2) child and (1) adult PFD(s).
Due 11 November 2008
Resolved 13 February 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 October 2008
Resolved
Submit repair proposal for delaminating aft bhd, both P/S hulls.
Due 11 November 2008
Resolved 13 February 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 October 2008
No resolution recorded
Replace fire extinguisher bracket with correct size.
Due 11 November 2008 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Not Operational
Issued 28 October 2008
Resolved
Replace broken portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2008
Resolved 13 February 2009
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 October 2008
Resolved
Remove water from forepeak, P/S hull.
Due 11 November 2008
Resolved 13 February 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 28 October 2008
Resolved
Provide documentation for drug testing program. (Proof of current standing w/Maritime Consortium, and list of enrolled crewmembers)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2008
Resolved 4 November 2008
Lifesaving › Lifebuoys › Size
Issued 18 September 2007
Resolved
Provide one 24 inch diameter life ring.
Due 2 October 2007
Resolved 24 September 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 September 2007
Resolved
Provide complete first aid kit.
Due 2 October 2007
Resolved 24 September 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 18 September 2007
Resolved
Secure electrical cables away from waterline and steering rod.
Condition: Improper/Lack of Maintenance
Due 2 October 2007
Resolved 24 September 2007
Construction/Loadline › Penetrations › Gasket
Issued 18 September 2007
Resolved
Seal penetration of port bilge electrical cable passing through bulkhead.
Due 2 October 2007
Resolved 24 September 2007
Construction/Loadline › Structures › Manhole
Issued 18 September 2007
Resolved
Secure hinges of port and starboard hatches.
Due 2 October 2007
Resolved 12 October 2007
Resolution: Corrected deficiency.
Construction/Loadline › Hull › Bottom Plating
Issued 18 September 2007
Resolved
Make bilge in starboard hull amidships ready for inspection.
Due 20 September 2007
Resolved 24 September 2007
Construction/Loadline › Hull › Stringer
Issued 18 September 2007
Resolved
Replace aft most athwart ship stringer.
Due 2 October 2007
Resolved 12 October 2007
Resolution: Corrected deficiency.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 22 September 2004
Resolved
Provide proof of annual servicing for all portable fire extinguishers.
Action required: 705 - Other - as specified
Due 6 October 2004
Resolved 6 October 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 September 2004
Resolved
Place two (2) portable lights on board.
Action required: 705 - Other - as specified
Due 6 October 2004
Resolved 6 October 2004
Engineering › Gasoline Engine (propulsion) › Spark Plug (2 stroke)
Issued 22 September 2004
Resolved
Properly secure all fuel tanks and battery boxes.
Action required: 705 - Other - as specified
Due 6 October 2004
Resolved 6 October 2004
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 October 2003
Resolved
Replace retro-reflective tape on life preservers as needed.
Due 3 November 2003
Resolved 22 September 2004
Lifesaving › Buoyant Apparatus › Marking
Issued 20 October 2003
Resolved
Replace life ring.
Due 3 November 2003
Resolved 22 September 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 October 2003
Resolved
Provide proof of servicing for portable fire extinguishers or proof of purchase within last 12 months.
Due 3 November 2003
Resolved 22 September 2004
Deck/Cargo › Holds/Tanks
Issued 2 December 2002
Resolved
Install high-water level audible alarm.
Due 3 December 2002
Resolved 5 March 2003
Resolution: Installed and tested sat.
Deck/Cargo › Holds/Tanks
Issued 2 December 2002
Resolved
Permanently install bilge pumps.
Due 3 December 2002
Resolved 5 March 2003
Resolution: Permanent installation sat.
Lifesaving › Lifebuoys
Issued 2 December 2002
Resolved
Make repairs to vessel's lifering.
Due 3 December 2002
Resolved 5 March 2003
Resolution: Repaired sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 2 December 2002
Resolved
Make repairs to life jacket as indicated during exam.
Due 3 December 2002
Resolved 5 March 2003
Resolution: New jackets on board.
Lifesaving › Lifejacket/PFD (General)
Issued 7 October 2002
Resolved
Replace retro-reflective tape that has weathered on 9 identified lifejackets. Tape to be CG and/or SOLAS approved. LEGACY COMPONENT DESC: Retroreflective Material
Due 7 November 2002
Resolved 5 March 2003
Resolution: New jackets.
Lifesaving › Lifejacket/PFD (General)
Issued 7 October 2002
Resolved
Replace 1 adult and 1 child lifejacket that are torn. LEGACY COMPONENT DESC: Condition
Due 7 November 2002
Resolved 26 November 2002
Lifesaving › Lifejacket/PFD (General)
Issued 7 October 2002
Resolved
Provide 1 more adult lifejacket to bring total number up to 46 adult lifejackets as per Certificate of Inspection.
Due 7 November 2002
Resolved 26 November 2002
Operations/Management › Drills/Instruction
Issued 7 October 2002
Resolved
Conduct and log required quarterly man-overboard and fire drills. Log entry to include date of drills, participants, and short summery of actions taken.
Due 7 November 2002
Resolved 26 November 2002
Communications › Alarms/Indicators
Issued 7 October 2002
Resolved
Prove operation of bilge high level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Due 7 November 2002
Resolved 26 November 2002
Engineering › Gasoline Engine (propulsion)
Issued 7 October 2002
Resolved
Provide secondary means at control station to stop engines.
Due 7 November 2002
Resolved 26 November 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 October 2002
Resolved
Provide Coast Guard approved 1st aid kit on board vessel.
Due 7 November 2002
Resolved 26 November 2002
Documentation › Certificates/Documents
Issued 7 October 2002
Resolved
Post original Certificate of Inspection on board vessel.
Due 7 November 2002
Resolved 26 November 2002
Operations/Management › Drug and Alcohol Testing
Issued 7 October 2002
Resolved
Show full compliance with DAPI audit as per check-off sheet provided.
Due 7 November 2002
Resolved 5 March 2003
Resolution: Complies.
Operations/Management › Drills/Instruction
Issued 7 October 2002
Resolved
Post Emergency Instruction List on board vessel.
Due 7 November 2002
Resolved 26 November 2002
Documentation
Issued 26 July 2001
Resolved
Post original copy of the Certificate of Inspection on board vessel, or have copy posted, with the original in a safe and dry location.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Construction/Loadline
Issued 26 July 2001
Resolved
Mark vessel's official number "D1107614" on hull inner structure and in such a way that any changes would be readily apparent.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Electrical
Issued 26 July 2001
Resolved
Mark electrical circuits on electrical panel switch plate.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Unknown
Issued 26 July 2001
Resolved
Provide confirmation that Henry A. Tubal is enrolled in the Maritime Consortium drug-testing program.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Lifesaving
Issued 26 July 2001
Resolved
Mark vessel name on all life jackets that have different vessel name. (Approx 12 jackets).
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Lifesaving
Issued 26 July 2001
Resolved
Mark vessel name on ring life buoy.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Fire Fighting
Issued 26 July 2001
Resolved
Provide proof of annual servicing of large (B-II) portable fire extinguisher.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Documentation
Issued 24 July 2000
Resolved
Obtain and post Garbage placard on board vessel.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 24 July 2000
Resolved
Stencil vessel name on all life jackets.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 24 July 2000
Resolved
Stencil vessel name on ring buoy.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Fire Fighting
Issued 24 July 2000
Resolved
Stencil "FIRE BUCKET" on fire buckets.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Fire Fighting
Issued 24 July 2000
Resolved
Obtain and mount a Coast Guard approved B-II portable fire extinguisher andbracket on board vessel. Vessel may not carry passengers until this is accomplished.
Condition: Unknown
Due 6 August 2000
Resolved 6 August 2000
Construction/Loadline
Issued 24 July 2000
Resolved
Install a bilge high-level indicator device with alarm in each hull of vessel.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 24 July 2000
Resolved
Provide workable flashlight for emergency use. Vessel may not carry passengers until this is accomplished.
Condition: Unknown
Due 6 August 2000
Resolved 6 August 2000
Documentation
Issued 24 July 2000
Resolved
Vessel admeasures at 5 gross tons, 5 net tons. In accordance with 46 CFR Part 67, vessel must be documented unless it can be proven tonnage is less than 5 net tons. Either provide proof of tonnage less than 5 net tons, or have vessel properly documented.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Construction/Loadline
Issued 24 July 2000
Resolved
Replace the white plastic discharge hose for each bilge pump with hose of more durable material.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Construction/Loadline
Issued 24 July 2000
Resolved
Install a metallic valve at the hull for each bilge pump discharge hose.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 24 July 2000
Resolved
Post an emergency instruction list on board the vessel.
Condition: Unknown
Due 6 August 2000
Resolved 6 August 2000
Documentation
Issued 24 July 2000
Resolved
Obtain and post Oil Discharge placard on board vessel.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000