MAURY USCG vessel records
← All vessels

CHEM 3703

Built
2012
Last inspected
5 July 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 5 July 2022
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2012–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1216195
Flag
UNITED STATES
Maury page id
psix-1216195

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2012
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portJEFFERSONVILLE, IN
Endorsements, as the file codes themcw_un
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHEM 3218 Tank Barge · MISLE 991130 · 24 February 2022 · activity 7405950AMERICAN SKILL Towing Vessel · MISLE 1409666 · 24 February 2022 · activity 7405950EDWARD A DAVIS Towing Vessel · MISLE 150030 · 9 August 2019 · activity 6777659MIKE HOWARD Towing Vessel · MISLE 204402 · 10 July 2015 · activity 5187156GERALD SHREVE Towing Vessel · MISLE 191185 · 9 April 2014 · activity 4835559

Inspection history · 19

5 July 2022 Cargo Tank Internal · COI Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7497188
24 February 2022 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7401267
24 February 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7405950
15 August 2019 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6784197
9 August 2019 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6777659
9 August 2019 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6777713
21 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6699526
17 April 2018 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6408967
2 June 2017 Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6161132
27 January 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6083856
17 February 2016 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5815369
13 July 2015 Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5187164
10 July 2015 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5179609
10 July 2015 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5187156
21 January 2015 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5064111
9 April 2014 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4833056
9 April 2014 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4835559
6 November 2013 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4750985
4 December 2012 Cargo Tank Internal · Deficiency Check · Initial Construction-Excluding Oversight · Administrative Inspection · Internal Structural Exam · Hull Examination · MTSA Verification · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4496153

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 July 2022 Resolved
The following locations in the weather are Class I, Division 1 (Zone 1) locations and may have only approved intrinsically safe, explosion proof, or purged and pressurized electrical equipment, and through runs of marine shipboard cable if the location is within 10 feet (3 m) of a cargo pipe flange. High level/overfill alarm panel and battery installation is within the hazardous area designation. Equipment needs to be installed outside the hazardous zone. 46 CFR 111.105-31(l)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2022
Resolution: Verified as corrected during COI attendance.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 February 2022 Resolved
A certificated barge must be maintained in a condition that is fit for route and service. Vessel was reported to be involved in a marine casualty and was ran aground. Damage assessment must be completed and all necessary repairs must be approved by the Coast Guard prior to returning to commercial service. Recovery operations shall cease until a salvage plan is received and approved by the cognizant OCMI 46 CFR 30.1-10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 August 2019 Resolved
Damage to external framong of cargo tank.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2019
Resolution: Marine Inspector Witnessed test of repair satisfactory. DEF cleared.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 10 July 2015 Resolved
Starboard forward bit was damaged during allision with Morgan City Railroad bridge. Fractured weld along the baseplate of bit. Bit is unsafe to use until weld repairs are completed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2015
Resolution: Damaged timberhead was replaced with a new set.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 4 December 2012 Resolved
Make permanent repairs to material defect in plate edge of stainless steel flame screen housing on the vacuum side of the VCS High Velocity valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2013
Resolved 9 January 2013
Resolution: Rcvd photos and repair work order documenting correction.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.