← All vessels
ELBRUNNER
ELBRUNNER is a 2009 freight ship. The Coast Guard has recorded 21 inspections since 2014, most recently in February 2024, along with 9 deficiencies — 1 with no resolution recorded — and 2 operational controls.
Records from 2014 to 2024. Most recent: inspection, 1 February 2024.
- Built
- 2009
- Last inspected
- 1 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9395563 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5DC5
1216623
Flag
CYPRUS
—
Maury page id
psix-1216623
Inspections, by type
…with no type recorded2
…past their stated due date1
Years with a record
11 calendar years (2014–2024)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8273 - Convention (Subpart B), Gross Ton
4002 - Convention (Subpart B), Net Ton
11007 - Dead Weight, Ton
15455 - Displacement, Ton
4002 - Convention (Subpart B), Net Ton
11007 - Dead Weight, Ton
15455 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
1 February 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7858990
26 January 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7856252
5 December 2023
Appeal
Administrative · Commandant (CG-CVC) · Activity 7833828
7 September 2023
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7786328
17 August 2023
PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7749528
12 August 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7763037
17 January 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7381387
13 July 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7254853
8 July 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7000079
12 December 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6872602
23 October 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6838960
2 October 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6825595
23 September 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6545518
5 August 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6500359
25 July 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6219963
26 July 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5953528
20 July 2016
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5946862
20 July 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5946990
4 November 2015
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5756947
22 October 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5007567
8 June 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4882643
Deficiency record · 9
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 1 February 2024
No resolution recorded
The company should ensure that each ship is manned with qualified, certificated, and medically-fit seafarers IAW national and international requirements. From Jan 01, 2024 till Jan 29, 2024, the company hired and provided to the vessel a 2nd Officer that was not qualified or certificated IAW national and international requirements. It is recommended that a safety management audit be carried out by the Administration.
74 SOLAS (20) IX/3.1
ISM Code 6.2.1
50abc
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 17 August 2023
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of deficiencies 02, 03, 04, and 06 provide objective evidence of serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to release from detention and clearance of this deficiency.
74 SOLAS (20) IX/3.1
ISM Code 10.1
30ABC
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 17 August 2023
Resolved
Oil filtering equipment shall be of a design approved by the Admin and will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 parts per million. During testing of OWS and OCM, PSCO observed Second Engineer utilize non-approved equipment to test the OCM. Second Engineer was not able to affirm proper testing or location of procedures. Engineering crew unfamiliar with pollution prevention equipment and procedures required by MARPOL and Safety Management Systems.
73 MARPOL (22) Annex I/14.6
30AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 August 2023
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. During exam of engine room, PSCO observed the ship lose full electrical power and go on emergency power due to the Chief Engineer and engineering crew bypassing required safety components on the ship’s main power generators to maintain intermittent operations of the generators.
74 SOLAS (04) II-1/41.1.1
30AC
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 August 2023
Resolved
The fixed fire detection shall be tested to the satisfaction of Admin by means of equipment producing hot air at the appropriate temperature to which the detector is designed to respond. PSCO observed crew testing flame detector with lighter. PSCO asked crew to provide testing equipment for heat and flame detectors, crew was unable to provide appropriate testing equipment approved by manufacturer.
74 SOLAS (20) II-2/7.3.2
30AC
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 August 2023
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. When PSCO asked crew to provide log of maintenance and testing of fire detection system, PSCO observed an empty log book.
74 SOLAS (20) II-2/14.2.2.1
30AC
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 August 2023
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the fire detection system. PSCO observed the fire control plan has not been updated since 2012 and does not show the current locations of flame detectors throughout the ship.
74 SOLAS (20) II/2 15.2.4.1
30AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2019
Resolved
The machinery...shall be of a design and construction adequate for the service for which they are intended. The vessel has reported that the main engine is functioning under a reduced capacity and is limited on maximum RPM and load upon arrival into Port of Miami, FL.
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 July 2016
Resolved
1530-Radar- All ships of 3,000 gross tonnage or upwards shall have a second radar. Vessels reported secondary radar as inoperable. 17ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.