MAURY USCG vessel records
← All vessels

PCF-816

PCF-816 is a 1968 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in January 2026, along with 43 deficiencies and 1 casualty investigation in 2020.

Records from 2016 to 2026. Most recent: inspection, 13 January 2026.

Built
1968
Last inspected
13 January 2026
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG8606
1217367
Flag
UNITED STATES
Maury page id
psix-1217367

Documentation record

Registered dimensions (L × B × D)51.3 ft × 13.6 ft × 6.3 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEWART SEACRAFT INC · BERWICK, LA, UNITED STATES · built 1968
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationCase Pending · issued 5 November 2012
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

13 January 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8296082
21 August 2025 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8215146
12 June 2024 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7939117
18 January 2024 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7850943
5 October 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7804250
9 January 2023 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7616042
5 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7425170
19 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7382426
15 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7175686
29 November 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134166
27 May 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6961539
1 April 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933961
15 January 2020 Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6890536
28 January 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6616661
13 December 2018 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6597418
26 June 2018 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6457028
5 June 2018 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434931
8 January 2018 COI Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334427
25 October 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6294902
30 March 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6114423
27 October 2016 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6031335
6 July 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5931475
22 June 2016 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5915288
19 April 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5857858
3 February 2016 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5809256
6 January 2016 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5792111

Deficiency record · 43

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2025 Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. The main and auxiliary steering apparatus shall be tested by operation and the inspector shall examine the mechanism thereof throughout its length. USCG Marine Inspector found the steering ram’s base plate to be loose when operated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2025
Resolved 30 September 2025
Resolution: Received confirmation from vessel rep that issue was resolved. All SAT.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 August 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel’s radio was missing latitude and longitude for DSC operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2025
Resolved 2 October 2025
Resolution: [name withheld] and Duarte attended vessel to clear def. ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 21 August 2025 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated or restricted to daytime operation. Provide light for the compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2025
Resolved 30 September 2025
Resolution: Received confirmation from vessel rep that issue was resolved. All SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 August 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. Provide visual indicator for automatic bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2025
Resolved 2 October 2025
Resolution: [name withheld] and Duarte attended vessel to clear def. ALL SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 August 2025 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. The records must be sufficient to Identify the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required by this part including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Vessel was missing 2024 report. Provide copy of 2024 report to local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2025
Resolved 22 August 2025
Resolution: Received picture of 2024 MIS report. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 January 2024 Resolved
Temporary repair present IWO port transom. Submit repair proposal for permanent repair to local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 June 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 January 2024 Resolved
Concentrated pitting found IWO fwd accom. space one longitudinal frame port and stbd of keel. Provide gauging report to determine extent of wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 June 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 January 2024 Resolved
Concentrated pitting found in engine room just aft of stbd side wet muffler. Provide gauging report of area between stbd side aft 2 transverse frames.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024 Resolved
Pitting found IWO port propeller root. Provide third party servicing report for propeller.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 June 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 January 2023 Resolved
Aft Engine room bulkhead portside; found 3/4 inch hole opened to lazerete space aft. Provide proper seal to bulkhead penetration.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 January 2023
Resolved 9 January 2023
Resolution: Crew provided mechanical seal (bolt, washer and nut) through bulkhead penetration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2022 Resolved
PORT MDE battery switch electrical cable run in bilge. Raise electrical cable run above bilges to appropriate level.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 2 May 2022
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 April 2022 Resolved
Engine room fixed fire fight bottle service tag expired as of 29JUNE2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 2 May 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022 Resolved
lazarette void STBD side outboard; electrical dead ended cable found.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 2 May 2022
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 April 2021 Resolved
Clean E/R bilges of oil and soaked sorbent pads.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2021 Resolved
Properly support cable runs laying in bilge up out of bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 15 April 2021 Resolved
Repair watertight hatch securing device and open deck penetration near hatch on port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2021 Resolved
Replace expired aspirin and missing instructions inside First Aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 April 2021 Resolved
Repair/replace light bulb to magnetic compass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 April 2021 Resolved
Heighten detachable railings to 39.5".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 April 2021 Resolved
Repair broken window at helm station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2021 Resolved
Repair pinholed exhaust pipe off stbd muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 11 May 2021
Resolution: Inspected by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 15 April 2021 Resolved
Lower rescue ladder down by 1-2 rungs to ensure crew/MOB can get onto vessel after MOB emergency.
Action required: 10 - Deficiency Rectified
Due 15 April 2021
Resolved 15 April 2021
Resolution: Lowered.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 January 2019 Resolved
Make all porthole weather tight as original installation
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2019 Resolved
Properly mark 01 child sized life jacket
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Properly Marked
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 January 2019 Resolved
Properly maintain forward emergency hatch dog mechanisms.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: The locking dogs were replaced and proved proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 January 2019 Resolved
Install a handle on ball valve on electric submersible hose discharge in forward compartment. Make valve available for closing.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Ball valved installed on bilge pump line
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Remove wires for temporary VHF radio or properly install permanently
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Wires were removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Properly protect each battery from falling objects.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Battery box cover was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Mount all wires above the bilges engine room and properly support with metal every 24".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: All wires were in the bilge were properly supported.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 January 2019 Resolved
Repair raw water pump gasket on portside main engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 February 2019
Resolution: Pump gasket was renewed
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 January 2019 Resolved
Install second hose clamp on small non metallic hose on portside exhaust piping.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Second clamp was installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 January 2019 Resolved
Make aft deck hatch opening to steering compartment water tight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 30 January 2020
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 January 2019 Resolved
Replace engine room ventilation closures to the satisfaction to the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Closures were renewed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 January 2019 Resolved
Install captive chain on forepeak deck watertight hatch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Captive chain installed
Electrical › Electrical Distribution System (service) › Cable
Issued 5 June 2018 Resolved
Provide proper electrical connection from the battery to the electrical panel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2018 Resolved
Make proper repairs and demonstrate the proper operation of the stbd MDE shutdwon solenoid.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Documentation › Markings/Placards › Warning Signs
Issued 16 January 2018 Resolved
Label forward emergency escape hatch on both sides.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Resolution: Emergency hatch properly labeled on both sides.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 January 2018 Resolved
Replace velcro for port and starboard intake ventilation closures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Resolution: Ventilation closures properly working.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 January 2018 Resolved
Renew gasket on starboard exhaust ventilation dampner
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Resolution: Gasket properly renewed.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 16 January 2018 Resolved
Renew second rung from bottom for MOB ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Resolution: Ladder was fixed
Electrical › Electric Supply System (service) › Battery Conductor
Issued 16 January 2018 Resolved
Remove electrical hazard for seafire control box. (install cover)
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Resolution: Electrical hazard eliminated.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 October 2017 Resolved
Vsl is past due its 90 day window for its required annual COI exam(due 09JUL17). Conduct satisfactory annual exam prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 16 January 2018
Resolution: Annual COI completed SAT
Construction/Loadline › Hull › Side Shell
Issued 3 February 2016 Resolved
Conduct haul out of the vessel for inspection prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2016
Resolution: Inserts welded in and tested.

Casualty record · 1

29 November 2020Routine · role: Involved in a Marine Casualty · activity 7134166
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.