LE SOLEAL is a 2013 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in March 2026, along with 19 deficiencies — 2 with no resolution recorded — and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 11 March 2026.
- Built
- 2013
- Last inspected
- 11 March 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 19 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded3
Years with a record
6 calendar years (2016–2026)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it12500 - Convention (Subpart B), Gross Ton
10950 - Regulatory (Subpart C or D), Gross Ton
3427 - Convention (Subpart B), Net Ton
1440 - Dead Weight, Ton
10950 - Regulatory (Subpart C or D), Gross Ton
3427 - Convention (Subpart B), Net Ton
1440 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 19
11 March 2026
PSC A · COC-CVE Annual · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8318994
15 April 2025
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8111854
31 March 2025
PSC B · COC-CVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8102099
31 March 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8102963
30 March 2025
COE-Administrative
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8101863
7 August 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7976353
21 March 2024
COE-Administrative · COC-CVE Annual · PSC A
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7882712
19 August 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6787888
6 July 2019
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6738283
3 July 2019
Examination of Repairs · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6735113
2 July 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6752635
31 March 2019
PII Safety Exam · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6647479
4 October 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6280858
3 October 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6280061
28 September 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6275059
26 October 2016
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6047498
12 September 2016
ISPS II Exam · COC-CVE Annual · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5994966
12 July 2016
In-Service Inspection · Security Breach, Potential
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5938933
6 June 2016
COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5899445
Deficiency record · 19
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2026
Resolved
Fire doors in main vertical zone bulkheads, galley, boundaries, and stairway enclosures; the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. PSCO observed the following: stairway FSD 1.12 and DB.05 closed in under 10s.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2026
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, opening shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed FSD DB 5.14 did not close and latch completely.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 March 2026
No resolution recorded
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon application of a force in the direction of escape flow. PSCO observed large public spaces labeled Main Lounge on DK3, Main Restaurant on DK2, and Theater on DK4 not be equipped with a quick release mechanism in way of escapes or had thumb latches in stalled in escape path.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2026
No resolution recorded
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed FSD DR 02 did not close and latch completely.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2025
Resolved
The construction of doors and door frames in 'A' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to tha of the bulkheads in which the doors are situated. The construction of doors and door frames "A" class divisions, with means of securing them when closed, shall provides resistance to fire as well as to the passage of smoke and flame equivalent material. Self-closing hose port o Fire Screen Door No. 4.04 failed to close all the way.
74 SOLAS 20 II-2/9.4.1.1.2
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2025
Resolved
Accumulator batteries shall be suitabily housed, and compartments used primarily for the accommodation shall be properly constructed and efficiently ventilated. PSCO observed storage of multiple spare wet cell batteries not sufficiently raised off the deck nor properly mounted and braced.
74 SOLAS 20 II-2/45.9.1
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 March 2025
Resolved
Spaces are classified acording to their fire risk as shown in categories (1) through (14). Zodiac workshop on deck 7 is a category (13) space where storage of wet cell batteries is prohibited. PSCO observes storage of 8 wet cell batteries.
74 SOLAS 20 II-2/9.2.2.3.2.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2025
Resolved
Fire doors in main verical zone bulkheads, galley boundaries and stariway enclosures, the approximate time of closure for hinged fire doors shal be no more than 40 s and no less than 10 s from the beginning of their movement. Fire screen doors (FSD) nos. 5.12 and 5.25 closed with 5 seconds before approximate minimum time of closure allowed.
74 SOLAS 20 II-2/9.4.1.1.5.2
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 31 March 2025
Resolved
Fire detection and fire alarm systems, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO was not able to witness satisfactory test of the heat detector in Hamman (Sauna)
74 SOLAS 20 II-2/14.2.1.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundaires, and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. Fire screen door (FSD) no. 1. 19 closed within five second before minimum approximate time of closure allowed.
74 SOLAS 20 II-2/9.4.1.1.5.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stariway enclosures, except those for emergency escape trunks shall be capable of remote release from the continuously manned central control station, either simultaneously or in groups, and shall be capable of release also individually at both sides of the door. PSCO observed galley roller shutter fire door, MVZ 2, Deck 6, would not close upon activation of local release mechanism.
74 SOLAS 20 II-2/9.4.1.1.5.3
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 March 2025
Resolved
Spaces are classified according to their fire risk as shown in categories (1) through (14). Electrcial substation 2 on deck 1 is a category (10) where storage of combustibles is prohibited. PSCO obseved storage of TVs, plastic hoses, cardboard boxes, and other miscellaneous items throughout the space.
74 SOLAS 20 II-2/9.2.2.3.2.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 March 2024
Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage for non-hazardous safety equipment and open information counters are permitted. PSCO observed storage of combustible materials under stairway enclosure leading to the bridge.
74 SOLAS 20 II-2/13.3.2.3.
16ac
Code- 07120
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 March 2024
Resolved
A' class doors located in stairways, public spaces and main vertical zone bulkheads in escape routes shall be equipped with a self-closing hose port. PSCO observed hose port on FSD 3.19 not fully closing, thus not keeping the class A fire boundary.
74 SOLAS 20 II-2/9.4.1.1.8
10c
Code- 07105
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 March 2024
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to fire their fire risk as shown in categories (01) to (14). PSCO observed AC rooms 07-03, 02-02, and the lift machinery room having storae of combustible materials (i.e.) cardboard).
74 SOLAS 20 II-2/9.2.2.3.2.2.
16ac
Code- 07101
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 March 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO double leafed FSD 3.13 closing much faster than 10 seconds.
74 SOLAS II-2/9.4.1.1.5.2
10c
Code- 07105
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 July 2019
Resolved
The condition of the ship shall be maintained to conform with the present regulations to ensure that the ship will remain fit to proceed to sea. Vessel has a rubber/epoxy patch over a hull penetration in the vicinity of the forepeak ballast tank. Provide a more suitable means of repair and submit a report from [name withheld] attesting to the suitability of that repair. - 74 SOLAS (14) I/11(a)
Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 28 September 2017
Resolved
Spaces are classified according to their fire risk as shown in categories (1)-(14). (10) Auxiliarry machinery spaces where storage of combustables is prohibited. Two category (10) spaces found containing combustables.
Construction/Loadline › Penetrations › Gasket
Issued 6 June 2016
Resolved
The emergency escape hatch in the boatswain store is not weather tight.