DREAM is a 2012 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in November 2024, along with 3 deficiencies — 1 with no resolution recorded —.
Records from 2016 to 2024. Most recent: inspection, 11 November 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it44422 - Convention (Subpart B), Gross Ton 27172 - Convention (Subpart B), Net Ton 94868 - Displacement, Metric Ton 81547 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
11 November 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8028474
7 July 2021PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7233826
27 March 2018PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6376598
18 September 2017Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6269226
5 October 2016Ballast Water Examination · ISPS II Exam · PII Safety Exam
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 November 2024No resolution recorded
Electrical installations shall be such that. PSCO observed epoxy repairs in way of electrical conduit at port side house shell plating.
SOLAS74 am II-I/40 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 July 2021Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed hold-back hooks on class A self-closing doors leading to galley from crew/officer mess rooms.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2021
Resolution: Received email from Flag attesting to hold back hooks being removed.
Construction/Loadline › Markings › Load Line Mark
Issued 5 October 2016Resolved
1200 - Loadlines - The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible. The loadline is rusted over and is not plainly visible. ICLL Reg 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 September 2017
Resolution: Vessel submitted International Anti-Fouling Cert and pictures rectifying the deficiency.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.