MAURY USCG vessel records
← All vessels

ORCA TOO

Built
1973
Last inspected
17 March 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 March 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC8089
121784
Flag
UNITED STATES
Maury page id
psix-121784

Documentation record

Registered dimensions (L × B × D)60.2 ft × 17.6 ft × 6.2 ft
Registered tonnagegross 71 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD BOAT WORKS · COSTA MESA CA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEWPORT BEACH, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 3 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

17 March 2025 Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067447
24 February 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067445
4 March 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7861808
20 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588920
7 March 2023 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588919
21 March 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7420364
15 March 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7149863
2 March 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7149285
10 March 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6887354
27 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6628270
5 March 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6620417
26 February 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6363601
31 May 2017 Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6162803
8 March 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6101446
2 March 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6071954
18 March 2016 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5817606

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2025 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Port and starboard Main diesel engines and generator did not shutdown upon CO2 pressure switch activation. Owner/operator must post instructions on how to properly secure engine in case of fire. 46 CFR 181.410 (b)(10)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 20 March 2025
Resolution: CO2 firefighting system now shutsdown MDEs, generator, and ventilation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 March 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel did not have a current navigational chart. 46 CFR 184.420 (a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 20 March 2025
Resolution: Vessel purchased new chart.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2025 Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Reach rod was improperly installed onto the screw down valve. Operator properly installed reached rod to the screw down valve handle. 46 CFR 182.510(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 17 March 2025
Resolution: Operator properly installed reached rod to the screw down valve handle.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2025 Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Lanyards on life floats lights were found deteriorated. Operator replaced deteriorated lanyards prior to completion of inspection. 46 CFR 180.175 (f)(4)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 17 March 2025
Resolution: Operator installed new lanyards.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 March 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel had expired first aid kit. Operator was able to purchase new first aid kit prior to complete of inspection. 46 CFR 184.710
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 17 March 2025
Resolution: Operator was able to purchase new first aid kit prior to complete of inspection.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 4 March 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. MI witnessed unsatisfactory man overboard drill. Ship's crew was unable to effectively demonstrate verbal communications and efficient CPR. 46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 7 March 2024
Resolution: Sent proof via e-mail of additional man overboard drills.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 20 March 2023 Resolved
At each inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection and operation of all watertight closures in the hull, decks, and bulkheads. While inspecting the lazarette, rotten wood was noted in the upper port quarter of the space where it connects to the main deck. Further inspection on deck showed a loosely-attached gooseneck fitting to the deck where water intrusion was evident.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 24 March 2023
Resolution: Repairs were completed on port quarter deck area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 March 2023 Resolved
Rail courses or the equivalent must be installed between a top rail and the deck so that no open space exists that is more than 12 inches high. Rail courses aft on the upper deck of the vessel in the way of an emergency escape ladder were found to be more than 12 inches off the deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 20 March 2023
Resolution: A rail course was added to safeguard passengers from falling down the ladder.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 March 2023 Resolved
Identified exposed electrical wires. Secure/cover exposed electrical wires above mirror in head compartment. 46CFR177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: Operator placed electrical tape around electrical wires. Will install light fixture in the near future.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2021 Resolved
THE WORDS FIRE BUCKET MUST BE STENCILED IN A CONSTRASTING COLOR ON EACH BUCKET. BUCKETS WERE NOT STENCILED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 March 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2021 Resolved
PLACARDS CONTAINING INSTRUCTIONS FOR THE DONNING AND USE OF THE LIFE JACKET MUST BE POSTED. PLACARD WAS NOT POSTED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 March 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 March 2020 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in vicinity of the vent. Port vent closure does not close all the way due to an obstruction. Make proper repair to ensure vent closure closes all the way.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
Resolution: Deckhand sawed a portion of the wood door flap in order to clear a machinery hose and close completely.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 March 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 11 March 2020
Resolution: New charts and publications have been placed onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2020 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Vessel has wing nuts on battery terminals. Install permanent type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 11 March 2020
Resolution: Wing nuts were removed and nuts were placed on the battery terminals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2020 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel does not have emergency instructions. Create vessel specific emergency instructions and post at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 11 March 2020
Resolution: Emergency instructions were posted and placed at the operating station.
Fire Fighting › Ventilation Systems › Ducts
Issued 26 February 2018 Resolved
Provide and prove proper operation for closing all supply duct cowls and scoops for engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 8 March 2018
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 February 2018 Resolved
Replace expired hydrostatic release and mark with new expiration date of two years from installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 8 March 2018
Lifesaving › Lifebuoys › Stowage
Issued 26 February 2018 Resolved
Water light permanently attached to ring life buoy. Purchase corrosion resistant clip and attach water light line, with clip on buoy side, to the buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Fixed on spot to satisfaction of attending Coast Guard Martine Inspector.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 26 February 2018 Resolved
Post emergency instructions at primary operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Fixed on spot to satisfaction of attending Coast Guard Martine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 31 May 2017 Resolved
Replace all Fixed Fire fighting piping to the satisfaction of the attending Marine Inspector
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 26 June 2017
Resolution: All piping and nozzles were replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 2 March 2017 Resolved
Install proper quantity of CO2 for the engine room fixed gas fire extinguishing system.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2017
Resolved 3 March 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.