MAURY USCG vessel records Sign in
← All vessels

ORCA TOO

ORCA TOO is a 1973 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1989, most recently in March 2025, along with 49 deficiencies, 1 operational control and 1 casualty investigation in 2010.

Records from 1989 to 2025. Most recent: inspection, 17 March 2025.

Built
1973
Last inspected
17 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8089
121784
Flag
UNITED STATES
367081510
Maury page id
psix-121784

Inspections, by type

…with no type recorded7
Years with a record 32 calendar years (1989–2025)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.2 ft × 17.6 ft × 6.2 ft
Registered tonnagegross 71 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD BOAT WORKS · COSTA MESA CA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC8089MMSI 367081510 · active · compulsorily equipped · granted 22 November 2025, expires 14 December 2035
WCW7639MMSI not assigned · expired · compulsorily equipped · granted 29 July 1996, cancelled 30 September 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

17 March 2025 Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067447
24 February 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067445
4 March 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7861808
20 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588920
7 March 2023 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588919
21 March 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7420364
15 March 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7149863
2 March 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7149285
10 March 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6887354
27 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6628270
5 March 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6620417
26 February 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6363601
31 May 2017 Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6162803
8 March 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6101446
2 March 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6071954
18 March 2016 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5817606
18 July 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4016987
5 May 2009 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3467500
24 April 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3163927
18 July 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952723
13 July 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993701
16 May 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2925510
22 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2652959
16 June 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2385335
14 June 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2385320
8 June 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2091674
9 July 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1833407
3 June 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1805423
5 June 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1626619
31 May 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362391
10 May 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384826
18 September 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376322
23 April 1999 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365169
27 May 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428968
5 June 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427370
1 May 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428753
10 June 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1456384
19 September 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402102
13 June 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377445
12 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144919
17 October 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 671290
31 August 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 212902
31 August 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 225286
11 July 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377223
16 March 1994 Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367006
13 May 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1143042
15 February 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1145629
5 May 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1257248
5 May 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258285
27 November 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 941218
27 November 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258284
8 October 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 938841
22 March 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1227043
7 February 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 926978
9 January 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908320
5 December 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 909866
30 November 1990 COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235068
11 January 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220409
9 January 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213103
5 October 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 915946
5 October 1989 Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1016837

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2025 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Port and starboard Main diesel engines and generator did not shutdown upon CO2 pressure switch activation. Owner/operator must post instructions on how to properly secure engine in case of fire. 46 CFR 181.410 (b)(10)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 20 March 2025
Resolution: CO2 firefighting system now shutsdown MDEs, generator, and ventilation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 March 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel did not have a current navigational chart. 46 CFR 184.420 (a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 20 March 2025
Resolution: Vessel purchased new chart.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2025 Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Reach rod was improperly installed onto the screw down valve. Operator properly installed reached rod to the screw down valve handle. 46 CFR 182.510(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 17 March 2025
Resolution: Operator properly installed reached rod to the screw down valve handle.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2025 Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Lanyards on life floats lights were found deteriorated. Operator replaced deteriorated lanyards prior to completion of inspection. 46 CFR 180.175 (f)(4)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 17 March 2025
Resolution: Operator installed new lanyards.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 March 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel had expired first aid kit. Operator was able to purchase new first aid kit prior to complete of inspection. 46 CFR 184.710
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 March 2025
Resolved 17 March 2025
Resolution: Operator was able to purchase new first aid kit prior to complete of inspection.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 4 March 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. MI witnessed unsatisfactory man overboard drill. Ship's crew was unable to effectively demonstrate verbal communications and efficient CPR. 46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 7 March 2024
Resolution: Sent proof via e-mail of additional man overboard drills.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 20 March 2023 Resolved
At each inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection and operation of all watertight closures in the hull, decks, and bulkheads. While inspecting the lazarette, rotten wood was noted in the upper port quarter of the space where it connects to the main deck. Further inspection on deck showed a loosely-attached gooseneck fitting to the deck where water intrusion was evident.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 24 March 2023
Resolution: Repairs were completed on port quarter deck area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 March 2023 Resolved
Rail courses or the equivalent must be installed between a top rail and the deck so that no open space exists that is more than 12 inches high. Rail courses aft on the upper deck of the vessel in the way of an emergency escape ladder were found to be more than 12 inches off the deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 20 March 2023
Resolution: A rail course was added to safeguard passengers from falling down the ladder.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 March 2023 Resolved
Identified exposed electrical wires. Secure/cover exposed electrical wires above mirror in head compartment. 46CFR177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2023
Resolution: Operator placed electrical tape around electrical wires. Will install light fixture in the near future.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2021 Resolved
THE WORDS FIRE BUCKET MUST BE STENCILED IN A CONSTRASTING COLOR ON EACH BUCKET. BUCKETS WERE NOT STENCILED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 March 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2021 Resolved
PLACARDS CONTAINING INSTRUCTIONS FOR THE DONNING AND USE OF THE LIFE JACKET MUST BE POSTED. PLACARD WAS NOT POSTED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 March 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 March 2020 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in vicinity of the vent. Port vent closure does not close all the way due to an obstruction. Make proper repair to ensure vent closure closes all the way.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
Resolution: Deckhand sawed a portion of the wood door flap in order to clear a machinery hose and close completely.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 March 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 11 March 2020
Resolution: New charts and publications have been placed onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2020 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Vessel has wing nuts on battery terminals. Install permanent type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 11 March 2020
Resolution: Wing nuts were removed and nuts were placed on the battery terminals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2020 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel does not have emergency instructions. Create vessel specific emergency instructions and post at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 11 March 2020
Resolution: Emergency instructions were posted and placed at the operating station.
Fire Fighting › Ventilation Systems › Ducts
Issued 26 February 2018 Resolved
Provide and prove proper operation for closing all supply duct cowls and scoops for engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 8 March 2018
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 February 2018 Resolved
Replace expired hydrostatic release and mark with new expiration date of two years from installation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 8 March 2018
Lifesaving › Lifebuoys › Stowage
Issued 26 February 2018 Resolved
Water light permanently attached to ring life buoy. Purchase corrosion resistant clip and attach water light line, with clip on buoy side, to the buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Fixed on spot to satisfaction of attending Coast Guard Martine Inspector.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 26 February 2018 Resolved
Post emergency instructions at primary operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 26 February 2018
Resolution: Fixed on spot to satisfaction of attending Coast Guard Martine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 31 May 2017 Resolved
Replace all Fixed Fire fighting piping to the satisfaction of the attending Marine Inspector
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 26 June 2017
Resolution: All piping and nozzles were replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 2 March 2017 Resolved
Install proper quantity of CO2 for the engine room fixed gas fire extinguishing system.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2017
Resolved 3 March 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 13 July 2007 Resolved
Fire extinguisher discharged/low pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Fire extinguisher serviced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 May 2006 Resolved
Prove proper operation of all fuel shutoff valves (4 total).
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 May 2006
Resolved 24 May 2006
Resolution: All valves are fully operational as of this date.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 May 2006 Resolved
Renew leaking shutoff valve on starboard inboard fuel tank.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 May 2006
Resolved 24 May 2006
Resolution: The starboard inboard fuel shuttoff valve was replaced and is functioning properly.
Fire Fighting
Issued 31 May 2001 Resolved
Servicing could not be verified.
Condition: Unknown
Due 7 June 2001
Resolved 17 August 2001
Lifesaving
Issued 31 May 2001 Resolved
All PFDs' straps were tied up/knotted which prevented donning of the jackets.
Condition: Unknown
Due 31 May 2001
Resolved 17 August 2001
Lifesaving
Issued 31 May 2001 Resolved
No spacers between stacked life floats.
Condition: Unknown
Due 31 May 2001
Resolved 17 August 2001
Documentation
Issued 10 June 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 August 1996
Resolved 26 June 1996
Fire Fighting
Issued 10 June 1996 Resolved
Plug hole on starboard side bulkhead in engineroom so that CO2 firefightingsystem in that space will be effective.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 10 June 1996 Resolved
Obtain Radiotelephony Certificate.
Condition: Unknown
Due 12 August 1996
Resolved 26 June 1996
Construction/Loadline
Issued 13 June 1995 Resolved
COMPLETE A CREDIT DRYDOCKING NOT LATER THAN 30 SETPEMBER 1995.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Construction/Loadline
Issued 13 May 1993 Resolved
PROVIDE REPAIR PROPOSAL FOR PATCHING OF TWO THRU-HULL PENETRATIONS (REMAINING FROM REMOVED SEA VALVES) PRIOR TO BEGINING REPAIRS, AND ENSURE THAT VESSEL IS AVAILABLE FOR INSPECTION AFTER HULL HAS BEEN PREPARED FOR REPAIRS AND AFTER REPAIRS HAVE BEEN COMPLETED.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Fire Fighting
Issued 27 November 1991 Resolved
PROVIDE A COPY OF THE FIRE FIGHTING EQUIPMENT SERVICE REPORT.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Documentation
Issued 27 November 1991 Resolved
PROVIDE A COPY OF THE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 27 November 1991
Resolved 27 November 1991
Construction/Loadline
Issued 9 January 1991 Resolved
REMOVE DECKING AND INSPECT HULL FOR DAMAGE DUE TO GROUNDING. DETERMINE EXTENT OF DAMAGE. MAKE NECESSARY REPAIRS AS REQUIRED BY, AND TO THE SATISFACTION OF, THE OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Fire Fighting
Issued 30 November 1990 Resolved
SERVICE FIXED FIREFIGHTING SYSTEMS FOR ENGINEROOM AND LAZARETTE AND PROVIDECOPY OF SERVICING REPORT.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Navigation
Issued 30 November 1990 Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR AT LOWER STEERING STATION.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Electrical
Issued 30 November 1990 Resolved
PROPERLY MOUNT HERTZ GAUGE AT UPPER STEERING STATION.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Documentation
Issued 30 November 1990 Resolved
PROVIDE VALID FCC SHIP STATION LICENSE FOR VESSEL.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Electrical
Issued 30 November 1990 Resolved
PROVE PROPER OPERATION OF AUXILIARY GENERATOR IN LAZARETTE, REMOVE WIRE NUT AND PROPERLY CONNECT WIRING IN CONTROL BOX, AND INSTALL GUARD FOR FLYWHEEL
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Fire Fighting
Issued 9 January 1990 Resolved
PROVIDE ON BOARD ONE FIRE AXE AS PER 46 CFR 181.35-1.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Fire Fighting
Issued 9 January 1990 Resolved
INSTALL ONE POWER PUMP MEETING THE REQUIREMENTS OF 46 CFR 181.10-1(C).
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Fire Fighting
Issued 9 January 1990 Resolved
INSTALL SUITABLE METTALLIC PIPING TO PROVIDE FOR TWO (2) 1.5 INCH HOSE STATIONS AS PER 46 CFR 181.15-5.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Fire Fighting
Issued 9 January 1990 Resolved
PROVIDE SUITABLE COMMERCIAL GRADE FIRE HOSES AND ALL PURPOSE NOZZLES FOR ALL REQUIRED FIRE STATIONS AS PER 46 CFR 181.15-10.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Lifesaving
Issued 9 January 1990 Resolved
PROVIDE ON BOARD TWO ADDITIONAL RING BUOYS AS PER 46 CFR 180.30-5(B), BRINGING THE TOTAL TO THREE (3).
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Electrical
Issued 5 October 1989 Resolved
CHANGE 12V DC NAVIGATION LIGHT CIRCUIT BREAKER TO A 5 AMP BREAKER TO COMPLYWITH 46 CFR 183.05-45(C).
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989
Electrical
Issued 5 October 1989 Resolved
CHANGE THE 12V DC ENGINEROOM BLOWER CIRCUIT BREAKERS PORT AND STBD TO 15 AMP BREAKERS TO COMPLY WITH 46 CFR 183.05-45(C).
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989
Electrical
Issued 5 October 1989 Resolved
CHANGE THE 12V DC FORWARD HEAD CIRCUIT BREAKER TO A 10 AMP BREAKER IN ORDERTO COMPLY WITH 46 CFR 183.05-45(C).
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989
Electrical
Issued 5 October 1989 Resolved
CHANGE 12V DC ANCHOR [name withheld] TO A 5 AMP BREAKER TO COMPLY WITH 46 CFR 183.05-45.
Condition: Unknown
Due 5 October 1989
Resolved 5 October 1989

Casualty record · 1

5 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3710718
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.