ARBORELLA is a 2012 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in June 2026, along with 3 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 12 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it39009 - Convention (Subpart B), Gross Ton 16720 - Convention (Subpart B), Net Ton 57539 - Dead Weight, Metric Ton 70605 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
12 June 2026Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8402822
9 June 2026PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8395527
3 April 2024Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7889323
13 April 2022Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7430571
1 March 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7403882
23 February 2022PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7396484
7 September 2019Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6805938
26 July 2019Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6755170
26 September 2017ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6268431
17 September 2017Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6268436
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 9 June 2026Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2026
Resolution: SEC DEL BAY rcvd class report and pictures documenting the new charges for the line throwing devices.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 February 2022Resolved
The purpose of regulation II-2/4.1 is to prevent the ignition of combustile materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed fuel leaks on the #1,2,3 ship's service deisel generator.
74 SOLAS (20) II-2/4.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2022
Resolution: Accepted class KR report stating multiple injectors, pumps, and filters were overhauled on generators, operation observed with no leaks, and leakage alarms tested.
After any survey of the ship under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. During the exam, the PSCO noted the fresh water solenoid valve had been renewed with wires spliced; ship did not have class approval documentation for the following modification.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2019
Resolution: Vessel submitted class survey report from Korean Register of Shipping verifying the proper operation and approval of OWS. See attached class report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.