Records from 2016 to 2026. Most recent: inspection, 17 April 2026.
Inspection history · 22
17 April 2026
PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8350553
18 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8162079
17 April 2025
COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8110787
26 February 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8085252
22 April 2024
PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7898566
11 April 2023
COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7663257
11 July 2022
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7504416
18 June 2022
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7481104
25 April 2022
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7435423
3 March 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7405212
27 May 2021
COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7201646
9 April 2020
Administrative Inspection · COC-TVE Renew
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6934627
28 May 2019
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6692496
30 January 2019
COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6617266
20 November 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6584589
3 November 2018
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6573868
9 August 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6505741
5 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6467875
6 April 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6386075
18 September 2017
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6267556
4 July 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6196774
9 December 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6055358
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2026
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it confroms to standards not inferior to those accepted by the organization.
The PSCO observed loose and exposed wiring on light in vicinity of BWTS on lower level of pumproom, motor on top of BWTS filter on starboard side of pumproom, lower bearing sensor for #1 and #2 cargo pumps as well as #2 ballast pump, and manual call point at the top pf the pump room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2026
Resolved 27 April 2026
Resolution: A Surveyor to Lloyd's Register North America attended the vessel. The vessel staff inspected the mentioned points and tightened the cable glands and reinspected to confirm their integrity. The repairs cable glands were checked and found Satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 April 2026
Resolved
Fire fighting systems and appliances shall be kept in good working condition and readily available for immediate use.
PSCO observed the following Class "A" self closing doors unable to close. CCR to conference room, galley to crew mess, air handling unit room, escape trunk lower level, fwd entrance to purifier room, and main stairs at main deck and a deck. additionally, observed vents in class b doors missing closing device for ships office and port side man deck access.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2026
Resolved 27 April 2026
Resolution: The vessel staff inspected the mentioned door and closing devices adjusted the hydraulic automatic closing devises to make the doors close smoothly and fully. After completion of the repairs inspected all the points and were found Satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 12 July 2022
Resolved
No person may get underway unless no more than 12 hours the emergency generator has been tested. Crew disclosed that the pre-departure emergency generator test had not been conducted as required.
33 CFR 164.25(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 12 July 2022
Resolution: The procedure for EDG test prior to departure will be reinforced, additional examinations of logs and procedures were carried out by LR Class Society
14 - Pollution Prevention › 148 - Ballast Water › Ballast water exchange
Issued 18 June 2022
Resolved
The Coast Guard may grant an extension to the implementation schedule listed in 151.2035(b) of this subpart only in those cases where the master, owner, operator, agent or person in charge of a vessel subject to this subpart can document that despite all efforts, compliance with the requirement under 151.2025 is not possible. The subject vessel violated the Coast Guard issued ballast water extension letter by not conducting a ballast water exchange before discharging untreated ballast water to the waters of Corpus Christi, Texas.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 June 2022
Resolution: Vessel returned to Port of Corpus after discharge ops at the CCLZ. Vessel conducted proper exchange and confirmed master was reminded that "Coastise Trade" was not an exemption available to foreign vessels.