MAURY USCG vessel records
← All vessels

KAVALA SEAS

KAVALA SEAS is a 2011 freight ship. The Coast Guard has recorded 1 inspection in 2016, along with 2 deficiencies.

Records in 2016. Most recent: inspection, 16 May 2016.

Built
2011
Last inspected
16 May 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9491252
1220287
Flag
LIBERIA
Maury page id
psix-1220287

Inspections, by type

Years with a record 1 calendar year (2016)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it33044 - Convention (Subpart B), Gross Ton
19231 - Convention (Subpart B), Net Ton
56830 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

16 May 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5878349

Deficiency record · 2

Engineering › Sea-water System (primary cooling) › Piping
Issued 16 May 2016 Resolved
Found 2 temporary patches on #2 SW cooling. Patch on SW out and SW inlet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 23 May 2016
Resolution: 23 May 2016: Recived Class report that shows deficiecy #01 issued has been cleared.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 16 May 2016 Resolved
Smoke detector over #1 SSDG not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 16 May 2016
Resolution: Replaced smoke detector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.