MAURY USCG vessel records
← All vessels

CHORUS

CHORUS is a freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in September 2017, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2017. Most recent: inspection, 28 September 2017.

Built
Not recorded
Last inspected
28 September 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 September 2017
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9461116
1220668
Flag
PANAMA
Maury page id
psix-1220668

Documentation record

Tonnage as PSIX records it43012 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

28 September 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6271733
1 October 2016 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6013729
27 August 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5984397
26 August 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5977172
17 August 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5975805

Deficiency record · 3

Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump Power Supply
Issued 27 August 2016 Resolved
CODE 0715 DETECTION: FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. DETECTOR ABOVE #2 GENERATOR IN ENGINE ROOM NOT OPERATIONAL. 74SOLAS(09)II-2/14.2.1.2, 17AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 October 2016
Resolution: CLEARED DEFICIENCY WITH PROPER DOCUMENTATION/CLASS REPORT.
Engineering › Steering Gear System › Follow-up Assembly
Issued 27 August 2016 Resolved
CODE 0936 STEERING GEAR: THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. #1 STEERING PUMP IS DRIFTING TO STARBOARD IN NON-FOLLOW UP CONTROLS. 74SOLAS(09)I/11, 17AC
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 1 October 2016
Resolution: CLEARED DEFICIENCY WITH PROPER DOCUMENTATION/CLASS REPORT.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 27 August 2016 Resolved
CODE 0999 OTHER (SAFETY IN GENERAL):ACCUMULATOR BATTERIES SHALL BE SUITABLY HOUSED, AND COMPARTMENTS USED PRIMARILY FOR THEIR ACCOMMODATION SHALL BE PROPERLY CONSTRUCTED AND EFFICIENTLY VENTILATED. #1 SET OF BATTERIES NOT PROPERLY INSTALLED FOR EMERGENCY GENERATOR. 74SOLAS(14)II-1/45.9.1, 17AC,
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2016
Resolution: 28AUG16: Cleared deficiency with NKK Class report. The crew fabricated a new box to enclose batteries with the surveyor's satisfaction. Box was provided with ventilation and fixed properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.