← All vessels
TRUST STAR
TRUST STAR is a 2012 freight ship. The Coast Guard has recorded 13 inspections since 2014, most recently in July 2026, along with 16 deficiencies and 2 operational controls.
Records from 2014 to 2026. Most recent: inspection, 13 July 2026.
- Built
- 2012
- Last inspected
- 13 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9610236 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HAG099
1220878
Flag
MALTA
—
Maury page id
psix-1220878
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it21838 - Convention (Subpart B), Gross Ton
36232 - Dead Weight, Metric Ton
43986 - Displacement, Metric Ton
12253 - Convention (Subpart B), Net Ton
36232 - Dead Weight, Metric Ton
43986 - Displacement, Metric Ton
12253 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
13 July 2026
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8436790
2 June 2026
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8377731
21 February 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7868069
9 February 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7863213
18 May 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7453623
15 August 2020
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7033789
23 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6631093
19 February 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6620990
28 August 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6250749
8 July 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5933969
21 March 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5837758
5 May 2014
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4849180
17 March 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4817816
Deficiency record · 16
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 2 June 2026
Resolved
The construction and means for securing the watertightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. PSCO observed 1/2" spacing on the #4 cargo hold pad while cleats were tightened down. Could not complete deck walk due to onload of ammonium nitrate. Verify all cargo holds.
ICLL 14.1
17ac
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2026
Resolved
Electrical installations shall be such that.. the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO identified 5 junction boxes on intermediate platform of main engine (ceiling port side) that are damaged and present personnel safety hazard.
75SOLAS(cons)
II-1/40.1.3
10c
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 2 June 2026
Resolved
The carriage of dangerous goods in solid form in bulk shall be in compliance with the relevant provisions of the IMSBC code.. Pressure on the fire mains shall be maintained for fire-fighting and fire hoses shall be laid out or be in position and ready for immediate use during loading. PSCO observed no water was immediately available for use while loading ammonium nitrate.
74 SOLAS (CONS)
VII/7-5
Annex 9, page 78
Ammonium nitrate UN1942
10c
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 2 June 2026
Resolved
Four sets of full protective clothing, resistant to chemical attack shall be provided in addition to the fire-fighters outfits required by regulation 10.10... PSCO observed only 3 sets of protective clothing available. Crew was able to compile a 4th set.
74SOLAS II-2/19.3.6.1
10c
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 June 2026
Resolved
The carriage of dangerous goods in solid form in bulk shall be in compliance with the relevant provisions of the IMSBC code... Prior to loading, the shipper shall provide the master with a certificate stating that the resistance to detonation of this material is in compliance with this requirement. PSCO identified that the certificate of detonation was not the correct certificate.
74SOLAS(cons)
VII/7-5
IMSBC Code Annex 9,
Page 77 Ammonium Nitrate UN1942
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 18 May 2022
Resolved
WATERTIGHT RECEPTACLES CONTAINING A TOTAL OF 3L OF FRESH WATER...FORE EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMODATE.
VESSEL HAD ONLY 140 OF 150 REQUIRED LIFEBOAT WATER PACKS.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 18 May 2022
Resolved
ALL ARRANGEMENTS USED FOR PILOT TRANSFER SHALL EFFICIENTLY FULFILL THEIR PURPOSE OF ENABLING PILOTS TO EMBARK AND DISEMBARK SAFELY. THE APPLIANCES SHALL BE KEPT CLEAN, PROPERLY MAINTAINED AND STOWED AND SHALL BE REGULARLY INSPECTED TO ENSURE THAT THEY ARE SAFE TO USE.
BOTH PILOT LADDERS WERE IMPROPERLY AFFIXED (AFFIXED TO COMBING).
74 SOLAS (20) V/23.2.1
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 18 May 2022
Resolved
PLANS AND BOOKLETS SHALL BE KEPT UP TO DATE: ANY ALTERATIONS THERETO SHALL BE RECORDED AS SOON AS PRACTICABLE.
VESSEL FIRE CONTROL PLAN DOES NOT REFLECT REQUIRED NUMBER OF LINE THROWING APPLIANCES AS REQURIED BY LSA CODE VII/7.1.1.3
74 SOLAS (20) II-2/15.2.4.1
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 19 February 2019
Resolved
11113- Launching arrangements for rescue boats- Before the ship leaves port and at all time during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed primary emergency mode power source (accumulator for rescue boat davit inoperable. SOLAS 74 a (2014) Cons III/20.2 17a
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 February 2019
Resolved
11104 -Rescue boats- Rescue boat shall be stowed: in a state of continuous readiness for launching in not more than 5 min... PSCO found primary and secondary fuel tanks in rescue boat near empty. SOLAS 74 a (2014) Cons III/14.1 17a
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 February 2019
Resolved
11132-Maintenance and inspections- Instructions for on-board maintenance of life-saving appliances comply with regulation 36 shall be provided and maintenance shall be carried out accordingly. PSCO found maintenance logs indicating davit accumulator had been inspected 16FEB19 and instruction manual requires a monthly pressure check of accumulator within a range of 10-21 MPA with oil added if below 18 MPA. During the inspection, accumulator had no pressure and did not function. SOLAS 74 a (2014) Cons III/20.3.2 16a
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 February 2019
Resolved
11132- Maintenance and inspections- The company should establish procedures, plans and instructions including checklists as appropriate for key shipboard operations concerning the safety of the personnel and ship. Vessel does not have procedures for post operational use of rescue/lifeboat to ensure operational readiness and stowed for immediate use. SOLAS 74 a (2014) Cons IX/3 ISM Code Part A Reg 7 16a
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 February 2019
Resolved
05199- At least 3 two-way VHF radiotelephone apparatus shall be provided on every passenger ship and on every cargo ship of 500 gross tonnage and upwards . PSCO found all spare batteries expired and all battery chargers were unplugged. SOLAS 74 a (2014) Cons III/2.1.1 17a
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 May 2014
Resolved
2510: Vessels must maintain a Ballast Water Management Plan that will allow those responsible for the plan to understand and follow it. Crew is not following current plan and ship does not have Bio-fouling Management Plan. 10c
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 May 2014
Resolved
0999: Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with protective caps in place. Oxygen and acetylene bottles in A/C room and storage lockers are not secured properly. Crew has used rope to secure them. 10c
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 May 2014
Resolved
0110: Lifesaving appliances and other equipment of Cargo Ships 500GT shall be annually surveyed. Annual survey was carried out on 11OCT2013, but several problems exist. Shipping bands are still attached to all 3 life rafts. Port painter to life raft is not attached, and markers showing location to immersion suits and life jackets forward are missing. 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.