Records from 2016 to 2025. Most recent: inspection, 23 December 2025.
Documentation record
Registered dimensions (L × B × D)178.0 ft × 39.8 ft × 14.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)178.0 ft × 39.8 ft × 14.0 ft
ITC tonnagegross 879 / net 350
BuilderC & C MARINE AND REPAIR LLC · BELLE CHASSE, LA, UNITED STATES · built 2013
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it879 - Convention (Subpart B), Gross Ton
89 - Regulatory (Subpart C or D), Gross Ton
350 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
23 December 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8275548
3 January 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8057031
2 October 2023
Drydock Exam · COI Inspection · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7798944
23 January 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7625422
12 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7449554
26 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7438812
13 January 2022
Periodic Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7378669
1 November 2021
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7343000
25 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7297197
2 July 2021
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7242378
31 March 2021
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7165581
13 January 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7123737
5 August 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7025144
7 January 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6883996
18 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6814736
16 October 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6561747
9 October 2018
Administrative Inspection · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6557626
27 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6362295
18 January 2018
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6327484
28 December 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6063209
13 October 2016
Hull Examination · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6021967
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2023
Resolved
Vessel must undergo an annual inspection w/in 3 months before or after each annerviery date. Vessel had isnepction outside the 3 month window. COI Date 16OCT. Inspection due by 16JAN.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2023
Resolution: Vessel had annual inspection on 23JAN2023.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 23 January 2023
Resolved
Rescue Boat and Equipment must be in good working order and ready for immediate use before vessel leaves port. Rescue boat White Light was identified as not working in OCT2022.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2023
Resolution: Vessel replaced the white light and submitted video to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 January 2023
Resolved
Weekly Requirement - Each lifesaving appliance & Launching appliance must be visually inspected; rescue boat must be run ahead and astern NLT 3 min; etc. Vessel had sporatic records or was completed monthly. 705 - Till next inspection.
Action required: 705 - Other - as specified
Resolved 5 October 2023
Resolution: Logs and maintenance records sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 January 2023
Resolved
Fire and Abandon ship drills shall be conpleted on alternating weeks. Drill Matrix shows fire and abandon ship drills once a month. Company shall update Drill Matrix.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2023
Resolution: Educated Master and Vessel Rep about drill requirement. Company shall update drill matrix.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2022
Resolved
Each inflatable life raft must be serviced. All life rafts on board were past their service interval. Vessel must provide service reports or alternate rafts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2022
Resolution: Vessel provided objectve evidence of replacement of life rafts.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 October 2018
Resolved
Demonstrate proper operation of rescue boat davit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2018
Resolved 16 October 2018
Resolution: Rescue boat davit cable replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 16 October 2018
Resolved
Replace lagging on both main diesel engines
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2018
Resolved 17 October 2018
Resolution: Lagging was replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 October 2018
Resolved
Replace gasket in engine room emergency escape hatch and replace gasket in rudder room water tight door.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2018
Resolved 16 October 2018
Resolution: Gaskets replaced
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 January 2018
Resolved
E light in FWD galley pantry was not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2018
Resolved 27 February 2018
Resolution: light was replaced and tested