← All vessels
PAC SEGINUS
PAC SEGINUS is a 2012 freight ship. The Coast Guard has recorded 33 inspections since 2014, most recently in January 2026, along with 12 deficiencies and 6 operational controls.
Records from 2014 to 2026. Most recent: inspection, 16 January 2026.
- Built
- 2012
- Last inspected
- 16 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9443358 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6225
1220923
Flag
SINGAPORE
—
Maury page id
psix-1220923
Inspections, by type
…with no type recorded7
Years with a record
12 calendar years (2014–2026)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it21094 - Convention (Subpart B), Gross Ton
10246 - Convention (Subpart B), Net Ton
27725 - Dead Weight, Ton
38361 - Displacement, Ton
21094 - Regulatory (Subpart C or D), Gross Ton
10246 - Regulatory (Subpart C or D), Net Ton
10246 - Convention (Subpart B), Net Ton
27725 - Dead Weight, Ton
38361 - Displacement, Ton
21094 - Regulatory (Subpart C or D), Gross Ton
10246 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
16 January 2026
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8294859
4 April 2025
Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8096751
10 March 2025
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8091063
12 September 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8001419
12 September 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8003981
27 August 2024
MARPOL Annex I Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7986785
26 March 2024
MARPOL Annex I Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7885031
14 November 2023
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7824421
25 May 2023
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7691975
8 September 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7554188
26 January 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7386327
12 January 2022
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7379182
25 July 2021
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7262454
14 July 2021
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7253242
25 February 2021
MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7146142
24 February 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7152721
23 February 2021
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7144400
1 October 2020
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7069181
14 September 2020
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7047749
27 April 2020
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6941753
2 December 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6861823
10 July 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6744618
4 July 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6735249
10 June 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6711937
8 November 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6574494
29 May 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6427891
29 May 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6428193
26 July 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6219451
14 July 2017
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6207452
25 February 2017
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6095731
13 June 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5905751
17 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5817193
13 May 2014
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4857672
Deficiency record · 12
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2021
Resolved
Electrical equipment and wiring shall not be fitted in enclosed cargo spaces. However, if electrical equipment is fitted in such spaces, it shall be of a certified safe type. PSCO obeserved multiple explosion proof lighting fictures in cargo area with cracked or missing covers and with water inside covers.
74 SOLAS (04) II-2/19.3.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 April 2020
Resolved
02199 Efficient Guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. PSCO observed guard rails on the port side main deck and the engine room were broken and corroded. ICLL (88) I/25 40 A/C
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 April 2020
Resolved
0710 The purpose of this regulation is to contain a fire in the space of origin. The divisions shall be maintained at the openings and penetrations. PSCO observed a penetration in the cable trunk room without insulation to maintain proper fire boundary compromising the fire integrity of the space. 74 SOLAS (14) II-2 9.1.3 10C
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 27 April 2020
Resolved
04103 During preparation and launching, the survival craft, its launching appliances and the area of the water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO observed the emergency embarkation flood light next to the rescue boat inoperable. 74 SOLAS (14) III/16.7 10C
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 April 2020
Resolved
15109 The condition of the ship and its equipment shall be maintained to conform to the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. PSCO noted a quick closing valves on the fuel oil day tank that was modified. Provide concurrence from class to the acceptance of this arrangement. 74 SOLAS (04) I/11(a) 40A/C
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2020
Resolved
07199 The purpose of this regulation is to prevent ignition of combustible material or flammable liquids. PSCO noted a gasoline tank from the rescue boat stored near the boiler in the engine room . 74 SOLAS (14) II-2 4.1.5 10C
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2020
Resolved
15109 The condition of the ship and its equipment shall be maintained to conform to the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. PSCO noted the supply valve for jacket water cooling was modified on the #2 SSDG. 74 SOLAS (04) I/11 (a) 40 A/C
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 2 December 2019
Resolved
07111 - Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use. PSCO noted gage on SCBA with 2 screws loose. SCBA was used in fire drill. Ship is required to have 3 fireman suits onboard. This SCBA was removed from service. Ship in compliance w/ fire control plan w/ 3 additional SCBA onboard. *Note: Crew repaired guage onboard, but replacement ordered.
74 SOLAS 04 con. II-2/14.1
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 November 2018
Resolved
07123-Operation of Fire Protection Systems-PCSO observed valve on water mist system secured. During expanded exam, pump was leaking and motor controller kept tripping during examination, not operating as designed. SOLAS 74 (2014) II-2/14.2.1.2
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 November 2018
Resolved
11129-PCSO observed during testing of lifeboat engine, that primary power source was unable to start engine. SOLAS 74 (2014) III/20.2
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 8 November 2018
Resolved
07118-PCSO observed International Shore Connection missing washers. SOLAS 74 (2014) II-2/14.2.1.2
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 26 July 2017
Resolved
0715- Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. PSCO obsevered inoperable flame detector over number 3 generator.Vessel crew replaced the flame detector and conducted a successful operational test.SOLAS74(2014 con)II-2/14.2.2.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.