Records from 2016 to 2026. Most recent: inspection, 11 March 2026.
Inspection history · 17
11 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8304258
11 February 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8063035
4 November 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8016456
7 March 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7866218
17 January 2023
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7608586
30 November 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7591665
30 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7388031
24 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7145528
9 December 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7109312
19 February 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6912776
23 January 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6604990
10 December 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6546233
1 February 2018
Administrative Inspection · DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6339217
3 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6116963
7 December 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6054792
25 May 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886061
14 March 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5828825
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2026
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The three required portable fire extinguishers on board have not undergone annual maintenance, as required by NFPA 10. Obtain required maintenance for all required portable fire extinguishers, or satisfactorily replace all required portable fire extinguishers to the satisfaction of the attending marine inspector. 46 CFR 176.810(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2026
Resolution: Vessel captain obtained new fire extinguishers to become in compliance with the required annual maintenance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2026
No resolution recorded
Each vessel must have permanent draft marks at each end of the vessel; or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable draft. Draft marks and/or loading marks are not present on the vessel's hull. During the vessel's scheduled dry dock in November 2026, properly affix permanent draft marks or loading marks to the vessel's hull, to the satisfaction of the attending marine inspector. 46 CFR 185.602(c)(1)&(2)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2026
Resolved
All fuel tanks must be electrically bonded to a common ground. The starboard fuel tank is not connected to the installed grounding wire. Connect the starboard fuel tank to a sufficient grounding wire to the satisfaction of the attending marine inspector. 46 CFR 182.440(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 12 March 2026
Resolution: Starboard fuel tank is now sufficiently connected to grounding wire.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2026
Resolved
The installation and location [of the portable fire extinguisher] must be to the satisfaction of the Officer in Charge, Marine Inspection. The brackets of the aft two portable fire extinguishers are wasted. Replace both brackets to the satisfaction of the attending marine inspector. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 25 March 2026
Resolution: Proper brackets have been installed for the aft two portable fire extinguishers. Photo has been uploaded under "documents" of this section.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 March 2026
Resolved
A vessel must comply with the applicable requirements, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The vessel's FCC station license is expired. Obtain a valid FCC station license to the satisfaction of the attending marine inspector. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 25 March 2026
Resolution: Vessel has emailed a copy of their FCC radio station lisence. Copy has been uploaded under "documents" of this section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2026
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placard is wasted and illegible. Replace life jacket donning placard to the satisfaction of the attending marine inspector. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 25 March 2026
Resolution: Life jacket donning placard has been replaced and is posted in a visible location. Photo has been uploaded under "documents" of this section.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 7 March 2024
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2) MMSI number on radio station certificate did not match the MMSI number on the radio. Ensure MMSI numbers match to the satisfaction of the Marine Inspector.
47 CFR 80.905(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 2 April 2024
Resolution: MMSI number on radio and station license match.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must be of at least 18.3 meters (60 feet) in length. Lifeline was only 50 feet long. Replace with correct length of line.
46 CFR 180.70 (c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2022
Resolved 23 June 2022
Resolution: Operator provided photographic evidence of adequate lifeline.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 January 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Starboard gasoline outboard engine's grounding wire is not attached. Reattach.
46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2022
Resolved 23 June 2022
Resolution: Operator provided photographic evidence of grounding wire attached to the starboard gasoline outboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 January 2022
Resolved
All equipment, including fuses, must be suitable for the voltage and current utilized. Incorrect fuses in the bilge pump circuit. Replace with correct size fuses.
46 CFR 183.220 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2022
Resolved 23 June 2022
Resolution: Operator provided photographic evidence of correct size fuses.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 January 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Starboard high water alarm light is not operational. Replace light.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2022
Resolved 23 June 2022
Resolution: Operator provided photograph of operational starboard high water alarm light.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 31 January 2022
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated or restricted to daytime operation. Vessel restricted to daytime ops until compass light fixed.
46 CFR 184.402
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2022
Resolved 3 August 2022
Resolution: Per owner's request, restricted vessel to daylight operations only. Updated and routed COI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 January 2022
Resolved
Each vessel certificated to operate on a limited Coastwise route within three miles of land in warm water must have on board a FCC Type Accepted Category 1 406 MHz EPIRB, installed to automatically float free and activate, for it to be not required to carry survival craft. EPIRB had incorrect registration decal. Update registration decal to match HANA HOU's assigned EPIRB.
46 CFR 180.205(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2022
Resolved 23 June 2022
Resolution: Operator provided photographic evidence of correct EPIRB registration decal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2022
Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. No evidence of crew training. Provide evidence of required crew training completed.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 23 June 2022
Resolution: Operator provided photographic evidence of completed crew training.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2022
Resolved
The official number of the vessel, preceded by the abbreviation “NO.” must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. Official number was not permanently affixed.
46 CFR 67.121
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2022
Resolved 23 June 2022
Resolution: Operator provided photographic evidence of permanently affixed official number.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for EPIRB expired. Install new hydrostatic release.
46CFR176.808(a)(5)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: HRU replaced, and expiration date labeled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2021
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required annual servicing to the marine inspector.
46CFR176.810(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: Fire extinguishers renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2021
Resolved
A portable hand bilge pump must be capable of pumping water. Required hand bilge pump was not onboard. Provide operable hand pump capable of pumping water from the space.
46CFR 182.520(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: Portable hand bilge pump placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2021
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q. Ring buoy is cracked, faded, and wasted in multiple areas. Provide new serviceable ring buoy.
46CFR180.70(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: Ring buoy renewed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2021
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of the vessel's fire buckets was broken. Replace with new fire bucket.
46 CFR 181.610
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: Ring buoy replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
46 CFR 16.210(a)
Action required: 10 - Deficiency Rectified
Due 24 February 2021
Resolved 24 February 2021
Resolution: Corrected in the presence of the attending Marine Inspector.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 19 February 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate high water levels in unmanned spaces. Port visual indicator alarm did not operate. Prove proper operation of visual indicator for port high water alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 21 February 2020
Resolution: Owner conducted in kind replacement of visual high water indicator at the operating station and proved operation as designed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 January 2019
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Vessel's visual indicator for its fwd stbd high water alarm is inoperable. Repair visual indicator for high water alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 January 2019
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC. Vessel's VHF-DSC has not registered their MMSI in system. Register MMSI
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Communications › Alarms/Indicators › High Water Alarm
Issued 3 April 2017
Resolved
Provide high water bilge alarm in STBD hull. 46CFR182.530(a)(3)
Condition: Placed in Improper Service
Due 17 April 2017
Resolved 22 May 2017
Resolution: Verified high water alarms installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 April 2017
Resolved
Visual indicator for operation of automatic bilge pump is missing. Provide a visual indicator at the operating station to indicate operation. 46CFR 182.530(c)
Condition: Invalid
Due 17 April 2017
Resolved 22 May 2017
Resolution: Verified visual indicators for automatic bilge pumps installed.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 3 April 2017
Resolved
Provide proper overcurrent protection for PORT high water alarm system, STBD AFT bilge pump control switches. 46CFR183.380(c)
Condition: Invalid
Due 17 April 2017
Resolved 22 May 2017
Resolution: Verified proper overcurrent protection installed.
Electrical › Electrical Distribution System (service) › Fuse
Issued 3 April 2017
Resolved
Provide UL listed fuses 46CFR183.380(1)
Condition: Invalid
Due 17 April 2017
Resolved 1 June 2017
Resolution: Provided UL listed fuses 46CFR183.380(1)
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 April 2017
Resolved
Provide operational compass light 46CFR184.402
Condition: Invalid
Due 17 April 2017
Resolved 22 May 2017
Resolution: Verified compass light operational.
Fire Fighting › Fire Bucket › Availability
Issued 3 April 2017
Resolved
Replace broken fire bucket(s)46CFR181.610
Condition: Damaged By Earlier Event
Due 17 April 2017
Resolved 22 May 2017
Resolution: Verified fire buckets carried onboard.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 April 2017
Resolved
Ensure circuit breaker meets UL 489 standard. 46CFR183.380(m)
Condition: Invalid
Due 17 April 2017
Resolved 22 May 2017
Resolution: Verified circuit breaker to include UL 489 breaker.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 March 2016
Resolved
Demonstrate proper operation of port side bilge high level alarm to ensure visual and audible alarms are provided at operating station
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2016
Resolution: Vessel replaced high level alarm prior to the end of inspection. Tested sat
Engineering › Fuel Oil Service System › Suction Strainer
Issued 14 March 2016
Resolved
Provide a drip pan fitted with flame screen to be installed under both gasoline strainers.
Condition: Placed in Improper Service
Due 14 April 2016
Resolved 1 May 2016