Records from 2014 to 2025. Most recent: inspection, 9 December 2025.
Inspection history · 21
9 December 2025
Periodic Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8281993
19 February 2025
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8081544
4 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7874096
13 September 2023
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7791096
13 September 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7803339
30 January 2023
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7630246
19 January 2023
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7623912
1 December 2022
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7602604
28 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7601964
11 July 2022
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7505480
8 July 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7505930
18 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7231606
8 June 2021
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7220796
6 May 2021
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7190867
7 May 2020
Administrative Inspection · Annual Inspection · Internal Structural Exam · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6949710
10 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6839659
30 September 2019
Examination of Repairs · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6826455
5 August 2019
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6773460
31 July 2018
Administrative Inspection · Internal Structural Exam · Hull Examination · MTSA Verification · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6513324
25 October 2017
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6294952
26 May 2016
MTSA Verification · Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5887551
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 March 2024
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves located at the tank. Valves installed on the outside of the oil tanks must be ... arranged with a means of manual control locally at the valve and remotely from a readily accessible and safe location outside of the compartment in which the valves are located. The remote fuel shut off valves located at the fuel oil tanks in both the starboard and port engine spaces were seized and inoperable at time of inspection. Vessel shall ensure valves are operable prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2024
Resolved 4 March 2024
Resolution: Vessel broke free both valves that were seized and made local and remote capability operable.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 September 2023
Resolved
The master or person in charge shall ensure that each crane is operated and maintained in accordance with the API Recommended Practice for Operation and Maintenance of Offshore Cranes, API RP 2D, First Edition (Oct. 1972) with supplement 1.
The large crane on-board vessel ruptured hydraulic line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 26 September 2023
Resolution: DMI received Tech Report from vessel rep. Tech report added to documents tab. Tech report Verify fully operational crane. resolved def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 November 2022
Resolved
Each lifebuoy must be marked in block capital letters with the name of the OSV and the name of the port required to be marked on the stern of the OSV under subpart 67.123 of this chapter. 46CFR133.70(a)(3)(ii). The marking on the lifebuoy on the STBD leg tower was faded. Vessel shall mark the STBD leg tower lifebuoy as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2022
Resolution: Lifebouy replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 28 November 2022
Resolved
Each OSV must have a line-throwing appliance that is approved under 160.031 or 160.040. 46CFR133.170(a). Line-throwing appliances approved under 160.031 must have 25 cartridges of the caliber and loading specified by the manufacturer of the gun. The cartridges must be blank with waterproof paper wad. 46CFR160.031-4(d). The line-throwing gun did not have 25 cartridges as required. Vessel shall ensure 25 required cartridges are provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2022
Resolution: Missing cartridges were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2022
Resolved
All jacking systems, holding mechanisms and associated systems are to be constructed and installed to the
satisfaction of the Surveyor in accordance with approved plans. Starboard and Port leg tower gearbox adapter housings had fastener nuts severely wasted. Starboard leg tower forward gearboxes 1 through 4 are to be removed and repaired one at time utilizing a vessel spare gearbox over a 90 day period. Starboard aft #4 and port forward 1 through 4 to be repaired during 2023 COI. 46 CFR 134.150, ABS Rules for Building and Classing Mobile Offshore Drilling Units 4/1.13.1 - 4/1.13.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2023
Resolved 23 February 2023
Resolution: Gear box housings were repaired and replaced and were in working order during the COI Renewal inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 November 2022
Resolved
Emergency lighting must be marked with a letter “E” at least 13 millimeters ( 1/2-inch) high. Several lights on the main deck were worn or missing. 46 CFR 131.840.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2022
Resolution: Stenciling was renewed.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 28 November 2022
Resolved
Except as specifically provided in this subchapter, electrical installations on an OSV less than 500 GRT must comply with subchapter J. 46CFR129.110(b). Emergency means of communication in a space throughout which the voice communcation station audible-signal device cannot be heard, there must be another audible-signal device or a visual-device, such as a light, either of which is energized from the final emergency bus. 46CFR113.30-25(g). The sound powered phone blue light visual-device in the STBD engine room was inoperable. Vessel shall ensure the blue light visual-device is operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2022
Resolution: Blue light was replaced in stbd engineroom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 November 2022
Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Starboard pressure vessel relif valve was set to 175psi with a 0-200 psi tank gauge. Minimum upper range of gauge required is 210 psi. Vessel to provide correct pressure gauge. 46 CFR 54.15-5(f).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 December 2022
Resolution: Gauge was replaced with a 0-300 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2022
Resolved
Each standard piping component for hydraulic control system must meet the requirements in 46 CFR 128.110 (c).
Hydraulic piping was corroded and damaged causing it to leak.
Action required: 10 - Deficiency Rectified
Resolved 11 July 2022
Resolution: Piping was cut back to good metal and replaced. Piping was secured to prevent further damage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 October 2019
Resolved
Except in an emergency, no repairs or alterations to the hull or machinery, or to equipment that affects the safety of the OSV, may be made without notice to the cognizant OCMI in the inspection zone where the repairs or alterations are to be made. When the repairs or alterations have been made, notice must be given to this OCMI as soon as practicable. Vessel installed a portable generator unit on the aft cargo deck and wired it into the port engine room switchboard panel OOA 04 July 2019. No notice to the local OCMI was given and vessel continued to work until it moored in New Iberia, LA for annual inspection preparations OOA 25 Sept 2019. 46 CFR 126.150(a)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
Resolution: Vessel repaired installed generator and removed portable generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 October 2019
Resolved
Drawings of repairs or alterations must be approved, before work starts, by the cognizant OCMI or, when necessary, by the Commanding Officer, Marine Safety Center (CO, MSC). Drawings will not be needed if deemed unnecessary by this OCMI or by the CO, MSC. Portable generator has different KW rating with a longer supplied electrical wire connection than that of the original generator. Changes in the electrical load analysis and requirements found in 46 CFR 111 are unknown. Local OCMI is requiring vessel to either replace original generator
in kind or submit updated electrical plans to MSC.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 October 2019
Resolution: Genset was replaced in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 September 2019
Resolved
Any vessel of at least 5 net tons engaged in coastwise trade must have a certificate of documentation bearing a valid endorsement. Vessel's original COD was not on the vessel. 46 CFR 130.240(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Original COD placed onboard
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 September 2019
Resolved
Each OSV of 100 or more gross tons must be fitted with anchors and chains meeting the applicable standards set by the ABS for classed vessels. Anchor flukes were seized preventing adequate holding capability. 46 CFR 130.240(a). 46 CFR 130.240(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Anchor was exercised and made free moving.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2019
Resolved
Each lifebuoy must be marked in block capital letters with the name of the OSV. Two lifebuoy's located on the main deck required stenciling to be renewed. 46 CFR 133.70(a)(3)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 10 October 2019
Resolution: Stencils were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 30 September 2019
Resolved
Each lifefloat must be arranged with a wire or line that encircles the body of the lifefloat and will not slip off. Painter lines that were attached to the lifefloats were attached to the lifefloat life lines. 46 CFR 133.130(c)(2)(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Painter lines were attached around body of lifefloats.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 September 2019
Resolved
Valves installed on the outside of oil tanks must be arranged with a means remote control from a readily accessible and safe location outside of the compartment in which the valves are located. Valves installed on the outside of oil tanks must be arranged with a means of remote control from a readily accessible and safe location outside of the compartment in which the valves are located. Remote fuel shutoff for the starboard fuel tank required repair to make operational. 46 CFR 56.60-50(d)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Fasteners were provided for the remote cable to the fuel tank valve handle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2019
Resolved
Fire axe must be marked with the vessel's name. Fire axe located on pilothouse bulkhead was not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 10 October 2019
Resolution: Fire axe stencling of vessel name provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 August 2018
Resolved
Disassemble and inspect lower most gearbox per leg as per CG 543 policy letter 07-02. Vessel's legs are configured with a double rack design that uses two lower gearboxes. Vessel provided inspection reports for only one lower gearbox. Vessel to disassemble and inspect the 3 additional lower gearboxes on port, stbd, and aft legs(F1P,F1S,and P1A). To be corrected by 2019 annual exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2019
Resolved 26 July 2019
Resolution: CG-835 was appealed and followed up with MSU Morgan City response leading to MSD Lafayette's supplementary inspection procuedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2018
Resolved
Propulsion shafting requires a means to observe rotation. Tachometer for port shaft does not register astern rotation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 20 August 2018
Resolution: Port tachometer was repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 August 2018
Resolved
Two emergency lights provided inadequate lighting for lifesaving and embarkation stations. Main deck light for aft port rope ladder and pilothouse light for rescue boat stowage had bulbs that were blown. Vessel to replace bulbs and test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 20 August 2018
Resolution: Bulbs were replaced and lights tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 August 2018
Resolved
Two lifefloats had damage to outer covering allowing water to come in contact with floatation material. Vessel to replae or repair both life floats.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 20 August 2018
Resolution: Both lifefloats were replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 August 2018
Resolved
Vessel requires a means to secure fuel supply to main engines operable from main deck. Port main fuel tank remote cut off valve would not turn and close valve. Vessel to repair.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2018
Resolution: Remote cable connecting to valve handle was repaired and tested satisfactory.