MAURY USCG vessel records
← All vessels

CHEM NORMA

CHEM NORMA is a 2009 tank ship. The Coast Guard has recorded 27 inspections since 2016, most recently in March 2023, along with 4 deficiencies and 5 operational controls.

Records from 2016 to 2023. Most recent: inspection, 23 March 2023.

Built
2009
Last inspected
23 March 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2023
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9486192
1221626
Flag
MARSHALL ISLANDS
Maury page id
psix-1221626

Documentation record

Tonnage as PSIX records it5180 - Regulatory (Subpart C or D), Net Ton
11939 - Convention (Subpart B), Gross Ton
22629 - Displacement, Metric Ton
17095 - Dead Weight, Metric Ton
5180 - Convention (Subpart B), Net Ton
11939 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

23 March 2023 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7655769
2 March 2023 COC-CHEM & TVE Annual · PSC B · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7644531
19 September 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7561701
19 September 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7562174
17 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7560963
9 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7555389
25 April 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7437693
21 February 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7396010
22 July 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7264214
10 June 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7219705
7 June 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7218204
12 February 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7139816
12 February 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7140253
9 August 2020 COC-TVE Renew · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7024544
26 November 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6586517
18 November 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6582789
5 April 2018 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6388568
22 March 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6376488
1 January 2018 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6331391
5 December 2017 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6323664
16 September 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6002113
12 July 2016 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5938442
17 May 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5879397
11 May 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5874556
27 April 2016 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5864507
1 March 2016 ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5821905
6 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5794952

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 March 2023 Resolved
Electrical equipment, cables and wiring shall not be installed in the hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization. PSCO observed deteriorated putty on light connections on both port and starboard catwalk lights. PSCO also observed improper connection on No. 4 port side high level alarm sensor, and damaged junction box near No. 4 port side tank.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2023
Resolved 15 March 2023
Resolution: Received Class Survey Report attesting to this deficiency being rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 March 2023 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. PSCO discovered repairs made to the vessel inert gas generator, and No. 1 port and No. 2 starboard tank flushing lines. Prior to conducting cargo operations for cargos which require inert gas or tank washing.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 23 March 2023
Resolution: Master provided documentation from the vessel's RO attesting that the deficiency has been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 14 March 2023 Resolved
The inert gas system referred to in chapter II-2 of the connection shall be designed, constructed and tested to the satisfaction of the administration. PSCO mulitgas meter oxygen sensor alarmed when testing the nitrogen generator. PSCO observed that the drain lines from the filters were not inside the deck drain and had to exit the space due to an oxygen rich environment. Prior to conducting cargo operations for cargos which require inert gas.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 23 March 2023
Resolution: Master provided documentation from the vessel's RO attesting that the deficiency has been rectified.
Engineering › Compressed Air System (start air) › Compressor
Issued 11 May 2016 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though [the air compressor and receiver for starting or control purposes] becomes inoperative. Verify start air arrangements are sufficient for the safe operation of the vessel.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2016
Resolved 11 May 2016
Resolution: Received, reviewed, and approved NKK Class Report. Surveyor conducted multiple start air tests, all tests passed. It is the opinion of the attending surveyor that the vessel is fit to sail its intended voyage.

Ownership record