← All vessels
NASHVILLE
NASHVILLE is a 2013 offshore supply vessel. The Coast Guard has recorded 15 inspections since 2016, most recently in November 2025, along with 4 deficiencies.
Records from 2016 to 2025. Most recent: inspection, 24 November 2025.
- Built
- 2013
- Last inspected
- 24 November 2025
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1244069
9688570
WDG9297
1221690
Flag
UNITED STATES
Maury page id
psix-1221690
Inspections, by type
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)106.8 ft × 66.5 ft × 10.0 ft
Registered tonnagegross 194 / net 132
ITC dimensions (L × B × D)106.8 ft × 66.5 ft × 10.0 ft
ITC tonnagegross 761 / net 228
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2013
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 January 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it769 - Displacement, Gross Ton
761 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Gross Ton
228 - Convention (Subpart B), Net Ton
132 - Regulatory (Subpart C or D), Net Ton
761 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Gross Ton
228 - Convention (Subpart B), Net Ton
132 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
24 November 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8272282
2 December 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8042208
30 August 2023
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7773406
7 July 2023
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7751592
22 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7559100
16 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7397250
16 August 2021
Periodic Inspection · Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7301744
3 August 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7278452
6 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7090712
10 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6832317
26 July 2018
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6490693
26 July 2018
Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6492212
13 November 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6305569
10 August 2016
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5969348
8 August 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5966316
Deficiency record · 4
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2024
Resolved
Each control system for a liftboat jacking system must be designed so that loss of power, loss of pressure in the hydraulic system, or low hydraulic-fluid level will activate a visible and audible alarm at the operating station and will not result in the liftboat's uncontrolled descent. Audible alarm for loss of pressure and fluid level was operational, but visual alarm must be made visible from the bridge (operating station).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2020
Resolved
46CFR134.150 (b) Lift-Jacking system-Each control system for a lifeboat jacking system must be designed so loss of power, loss of pressure in the hydraulic system or low hydraulic-fluid level will activate a visual and audible alarm; vsl had disconnected the low hydraulic level fluid sensor preventing audible and visual alarm; vessel is to make repairs to the requirements in 46CFR134.150 prior to departure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 November 2020
Resolved
2)46CFR174.210(c)(3)A Class-1 door may be installed at any place if-The vessel’s pilot house contains a visual indicator showing weather the door is open or closed; The vessel watertight door indicator was not aligned properly to indicate visual indicator for the open or closed position; make repairs IAW 46CFR174.210(c)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 November 2020
Resolved
3)46CFR 54-15-5 (f) Protective devices- Where press-indicating gauges are used, they shall be chosen to be comparable with the pressure to be indicated; in no case shall the upper range of the gage be less than 1.2 times more more than 2 times the pressure at which the relieving device is set to function; vessel’s gauge max pressure at 200 with relief set at 195; replace gauge IAW 46CFR54-15(f).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.