Records from 2017 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 50
25 February 2026
PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8312799
12 December 2025
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8282473
22 November 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8272484
22 November 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8277691
20 November 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8271973
20 November 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8273759
19 September 2025
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8237429
2 July 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8173569
27 June 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8168772
17 March 2025
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8094758
26 February 2025
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8085007
21 February 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8082797
26 September 2023
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7798448
21 September 2023
Deficiency Check · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7795457
29 July 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7752640
21 July 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7748199
21 May 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7691487
1 September 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7548989
29 July 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7519537
22 July 2022
MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7513417
21 July 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7509722
7 June 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7465249
25 April 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7437449
26 June 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7236355
26 June 2021
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7236367
18 May 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7200043
8 May 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7193000
8 May 2021
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7193018
23 March 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7158442
6 February 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7136552
5 January 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7119713
1 January 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7119489
26 December 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7116378
17 September 2020
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7059877
25 March 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6931713
18 March 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6928450
13 February 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6904292
4 January 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6881167
19 November 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6856357
13 October 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6833552
13 October 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6833871
30 September 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6824933
13 August 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6782645
1 May 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6674418
30 January 2019
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6621024
28 January 2019
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6615791
16 January 2019
COE-Administrative · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6610713
6 February 2018
ISPS III Exam · COE-Dockside
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6350095
14 August 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6240219
13 July 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6207447
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2025
Resolved
The machinery and associated piping systems and fittings shall be a design and construction adequate for the service for which they are intended. PSCO received a report that main engine failed to start.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 12 December 2025
Resolved 12 December 2025
Resolution: Received class report attesting to the working order of the ship.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 17 March 2025
Resolved
74 SOLAS (24) V/19.2.11.4
The navigational equipment and systems referred to in this regulation shall be so installed, tested and maintained as to minimize malfunction. PSCO observed low battery alarm on navigational echo sounder.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2025
Resolution: Received class report from RINA attesting to the replacement of the echo depth sounder battery.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 26 February 2025
Resolved
All Cargoes, other than solid or liquid bulk cargoes, cargo units and cargo transport units carried, shall be loaded, stowed and secured throughout the voyage in accordance with the Cargo Securing Manual approved by the Administration. PSCO observed 4-door sedan on deck 11 and a ford transit van on deck 3 with lashing belt hooked directly on the wheel rim rather than threaded through and around the rim as stated as such within vessel’s Cargo Securing Manual. 74SOLAS(20) VI/5.6
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2025
Resolution: Spot checked cargo on all decks, all sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. PSCO observed low-pressure CO2 holding tank #1 empty due to system discharge during fire that occurred on board during incident on 17FEB25. 74SOLAS(09) II-2/14.2.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 March 2025
Resolution: Recieved Hiller report attesting to CO2 system being recharged, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 26 February 2025
Resolved
Cargo, cargo units and cargo transport units carried on or under deck shall be so loaded, stowed and secured as to prevent as far as is practicable, throughout the voyage, damage or hazard to the ship and the persons on board, and loss of cargo overboard. During recent voyage, cargo became loose and caused significant damage to the vessel and broke out into a fire. 74SOLAS(20) VI/Reg5.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2025
Resolution: All damaged cargo has been removed. All undamaged cargo was secured IAW cargo securing plan.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 February 2025
Resolved
Ro-ro spaces shall be fitted with fixed fire detection and fire alarm system complying with the requirements of the Fire Safety System Code. PSCO observed fire detection system on deck 3 damaged due to recent fire. 74SOLAS(09) II-2/REG19.3.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2025
Resolution: Received class report from RINA attesting to the smoke detection system being repaired/renewed and in good working order.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 26 February 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met, ignition sources shall be restricted. PSCO observed deck 3 covered with large amounts of hydraulic oil due to recent fire onboard. 74SOLAS(09) II-2/Reg4.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: oil has been cleaned, no evidence of leak remains.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 February 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed forward 6-man life raft damaged. 74SOLAS(09) III/Reg20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: liferaft has been replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so install and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed a jacket water leak on the main engine cylinder #1
74SOLAS(14) II-1/Reg 26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: jacket water leak has been repaired, no evidence of leak remains.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 February 2025
Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the Code. Every totally enclosed lifeboat shall be provided with rigid watertight enclosure which completely encloses the lifeboat. The enclosure shall be so arranged that access to the lifeboat is provided by hatches which can be closed to make the lifeboat watertight. PSCO observed aft hatch on portside lifeboat was unable to seal and witnessed daylight coming through. 74SOLAS(09) III/Reg34
LSA Code 4.6.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: lifeboat aft hatch has new gasket, door is watertight. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a fuel oil leak from the diesel auto fuel oil filter. 74SOLAS(09) II-2/Reg4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: oil cleaned, no evidence of leak remains.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2025
Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed gas fire-extinguishing system complying with the provisions of the Fire Safety Systems Code. The two controls shall be located inside a release box clearly identified for the particular space. If the box containing the controls is to be locked, a key to the box shall be in a break-glass -type enclosure conspicuously located adjacent to the box. PSCO observed key box in the fire control locker near bridge on stbd side had broken glass from energizing the system during recent fire. 74SOLAS(09) II-2/Reg10.4.1.1.1
FSS Code 5.2.2.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2025
Resolution: glass has been replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 26 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain safe to proceed to sea without danger to the ship or persons on board. Stern ramp hydraulic system in deck 3 is damaged and inoperable but can be opened/closed manually. 74SOLAS(20)I/11
(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 June 2025
Resolved 2 July 2025
Resolution: Recieved class report
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 February 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed firefighting equipment and fire main damaged from fire. 74SOLAS(09) II-2/Reg14.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2025
Resolution: Received class report from RINA attesting to the renewal of the damaged parts of the fire line and 3 renewed fire hydrants.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handles or touched in the normal manner. PSCO observed significant damage to electrical components on deck 3 due to fire. 74SOLAS(09) I-1/Reg45.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2025
Resolution: Received class report from RINA attesting to the repair of electrical components on deck 3
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 February 2025
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with he recommendations of the Organization, indicating the devices stowed in that location for that purpose. If more than one device is stowed in that location, the number of devices shall also be indicated. PSCO observed bridge PFDs and line-throwing devices not labeled with number of each on the stbd side of bridge. 74SOLAS(09) III/Reg20.10
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 March 2025
Resolution: IMO stickers and amount of each has been updated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed several damaged transverse frames on deck 3 and larger projections in the shell plate on port side near bow. 74SOLAS(20) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2025
Resolution: Received class report from RINA attesting to the permanent repair of damaged deck plates on deck 3
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 September 2023
Resolved
EXPOSED METAL PARTS OF ELECTRICAL MACHINES OR EQUIPTMENT... SHALL BE EARTHED. EXHAUST FAN ARRANGEMENTS FOR PORT SIDE DECKS NO. 6, 7, 9, 10, AND 11, AND STARBORD SIDE DECKS 9,10, AND 11 ARE MISSING GROUNDING WIRES OR WIRES ARE PLACED IN IMPROPER SERVICE
74SOLAS(20)II-1/45.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2023
Resolution: Sec NY received class report attesting to deficiencies being corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 September 2023
Resolved
... ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION, AND UTILIZATION OF THE OIL FUEL SHALL BE AS SUCH TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. DIESEL OIL SERVICE TANK USED TO FILL THE SHIP'S CARGO EQUIPTMENT WAS OBSERVED TO HAVE A RAG WRAPPED AROUND THE HOSE CONNECTION AND LEAKING. SHIP'S CREW UTILIZING UNAPPROVED STORAGE CONTAINERS TO STORE DEISEL OUTSIDE THE TANK.
74SOLAS(20)II-2/4.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2023
Resolution: Sec NY received class report attesting to deficiencies being corrected.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 September 2023
Resolved
The fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection including fire-resisting divisions, and protection of openings and penetrations in these divisions.Self closing fire door for cargo office on deck 3 and emergency escape on deck 9- port side- aft did not close properly.
74SOLAS(20)II-2/14.2.1.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2023
Resolution: Sec NY received class report attesting to deficiencies being corrected.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 July 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection including fire-resisting divisions , and protection of openings and penetrations in these divisions. Found multiple self-closing fire doors in A60, A0, and B15 boundaries not able to close and latch.
74 SOLAS(04) II-2/14.2.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2023
Resolved 30 July 2023
Resolution: Received close out letter from vesssel class society.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 July 2023
Resolved
All cargoes... shall be loaded, stowed, and secured throughout the voyage in accordance with the cargo securing manual approved by the administration. PSCO observed vehicles on 03 different decks secured to fence post or knife edge on side of deck.
74 SOLAS (20) VI/5.6
17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2023
Resolved 21 July 2023
Resolution: Crew was able to secure cargo properly to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 21 July 2023
Resolved
The company should establish procedures to ensure that new personnel and personnel transferred to new assignments related to safety... are given proper familiarization with their duties. Crew members conducting rounds of cargo decks are not reporting/ fixing improper lashing arrangements as required by vessel's SMS.
74 SOLAS (20) IX/3.1
ISM Code 6.3
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2023
Resolved 21 September 2023
Resolution: cleared with proper documentation which included internal audit results carried out by Class and observed implentation of cargo checks by C/O in port log book.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 July 2022
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The objective nature of the deficiencies 02 and 03 demonstrate the vessel is not being maintained to international standards bringing into question the validity of the safety management certificate issued pursuant to the ISM Code. An external Audit is required to be submitted prior to departure from port.
74 SOLAS (20) IX/5
ISM A/10.1
Action required: 30 - Ship detained
Resolved 23 July 2022
Resolution: SEC JAX received ISM Audit report from RINA noting 1 n/c and one observation being rectified as per the requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 22 July 2022
Resolved
After any survey of the ship under paragraph 1 of this regulation has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey, without the sanction of the administration, except the direct replacement of such equipment and fittings. PSCOs observed unauthorized modification of sludge system after survey by utilizing an air driven pump.
MARPOL Annex 1/6.4.2
Action required: 30 - Ship detained
Resolved 23 July 2022
Resolution: SEC JAX received class report and ISM audit attesting to the removal of the unapproved additional pump and piping.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 22 July 2022
Resolved
Oil residue(sludge) tank(s) shall be provided and: shall be provided with a designated pump that is capable of taking suction from the oil residue(sludge) tank(s) for disposal of oil residue(sludge) by means as described in regulation 12.2. PSCOs observed piping modifications to utilize an air driven pump that was not authorized.
MARPOL Annex 1/12.3.2
Action required: 30 - Ship detained
Resolved 23 July 2022
Resolution: SEC JAX received class report and ISM audit attesting to the removal of the unapproved additional pump and piping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 July 2017
Resolved
The 15 ppm bilge alarm should record date, time, and alarm status, and operating status of the 15 ppm bilge separator. During operational test of the oily water separator, PSCO observed that the oil content meter was not making accurate recordings.
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 14 August 2017
Resolution: Received Class report clearing deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 13 July 2017
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occur;...fire detection and fire alarm systems.
See attached form B for deficiency write up.
74 SOLAS (2014 CONS)
II-2/14.2.1.1.2
50AC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 14 August 2017
Resolution: Received Class report clearing deficiency.