CLIPPER CLYDE is a 2012 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in April 2023, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2023. Most recent: inspection, 24 April 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19998 - Convention (Subpart B), Gross Ton 31638 - Dead Weight, Metric Ton 40376 - Displacement, Metric Ton 10444 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
24 April 2023PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7670910
2 July 2021PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7242433
27 June 2019Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6727748
11 June 2019ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6710458
13 October 2017Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6287200
27 August 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6252892
26 August 2017Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6252346
24 August 2017PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6247121
22 August 2017Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6249553
21 August 2017Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6247215
16 May 2016ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5871259
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 20 June 2019Resolved
EACH INCINERATOR INSTALLED ON BOARD A SHIP ON OR AFTER 1 JANUARY 2000 SHALL MEET THE REQUIREMENTS CONTAINED IN APPENDIX IV TO THIS ANNEX. THE REFRACTIVE MATERIAL IN THE INCINERATOR IS CRACKED AND DETERIORATED IN MULTIPLE AREAS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 27 June 2019
Resolution: CREW REPLACED THE WHOLE REFRACTICE MATERIAL TO SATISFACTION OF THE COAST GUARD.
2199- Other (MARPOL Operational Def)- Except as provided in Paragraph 6.2 of this regualtion, each incinerator on a ship constructed on or after 1 January 2000 shall meet the requirements contained in appendix IV of this annex. PSCO observed incinerator is inoperable. Received dispensation letter from flag state and repair plan. MARPOL VI/16.6.1 - 16C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 13 October 2017
Resolution: PSC NOLA received proper documentation from the ship proving that the incinerator was in good working order.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 16 May 2016Resolved
0715 - Fire Detection - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed a fault code for Zone 001 and fire detector A002 on the fire control repeater panel in the Engine Control Room. 74 SOLAS (14) II-2/14.2.1.2 10c
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 16 May 2016
Resolution: Crew replaced smoke detector and tested to the satisfaction of the Coast Guard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.