MAURY USCG vessel records
← All vessels

AMIRANTE

AMIRANTE is a 2013 tank ship. The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 6 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 7 March 2026.

Built
2013
Last inspected
7 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 March 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9629706
V7A6466
1222892
Flag
MARSHALL ISLANDS
Maury page id
psix-1222892

Documentation record

Tonnage as PSIX records it29983 - Convention (Subpart B), Gross Ton
49994 - Dead Weight, Metric Ton
60692 - Displacement, Metric Ton
13397 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

7 March 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8321310
2 December 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8039151
11 March 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7877442
27 December 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7842711
14 December 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7838899
13 December 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7838793
11 December 2023 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7837386
20 February 2022 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7397501
13 March 2021 PSC B · COE-Offshore · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7151303
13 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7155625
8 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7152199
1 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6934149
27 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6932191
27 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6932217
2 December 2019 In-Service Inspection · ISM Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6865367
19 September 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6815546
5 November 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6575004
4 October 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6553736
25 September 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6547989
2 October 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6275360
13 October 2016 Administrative Inspection · COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6021442

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2023 Resolved
The gas detection equipment shall be so designed that it may readily be tested. PSCO was unable to test fix gas detection system due to span Gas being unavailable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 27 December 2023
Resolution: Vessel provided invoice for calibration gas.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 20 February 2022 Resolved
The voyage data recorder system, including all sensors, shall be subjected to an annual performance test. The test shall be conducted by an approved testing or servicing facility to verify the accuracy, duration and recoverability of the recorded data. In addition, tests and inspections shall be conducted to determine the serviceability of all protective enclosures and devices fitted to aid location. A copy of the certificate of compliance issued by the testing facility, stating the date of compliance and the applicable performance standards, shall be retained on board the ship. PSCO observed VDR survey, however the certificate of compliance issued by the testing facility could not be provided. SOLAS V/18.8
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2022
Resolved 2 March 2022
Resolution: Received and accepted class LR correspondence and supporting docs. VDR conformance test certificate issued to vessel
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2022 Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. PSCO observed aft mooring winch motor controller beaker was double tapped with a 440V outlet. SOLAS II-1/45.6.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2022
Resolved 2 March 2022
Resolution: Received and accepted class LR correspondence and supporting docs. 440V pigtail removed from mooring winch motor controller, restored to orignial condition.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 19 September 2019 Resolved
10101- The side ropes of the Pilot Ladder should consist of one continuous length of rope,the midpoint half-length being located on a thimble large enough to accommodate at least two passes of side rope. The midpoint half-length of both port and starboard pilot ladders were cut, removing the thimble to splice an extended length of rope, and are no longer continuous. 74SOLAS(14)V/23.1.2 RES. A. 1045(27)/2.2.1 17 A.C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2019
Resolution: Class sent in report with a short term modification and open condition of class due for full repair/replacement by 31OCT19.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 September 2019 Resolved
07108- Fire Extinguishers shall be situated ready for use at easily visible places which can be reached quickly and easily. The housing for the Fire Extinguisher on the starboard manifold could not be opened. 74SOLAS(14)II.2/10.3.2.4 17 A.C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2019
Resolution: Class sent in report with a repairs made by vessel crew to satisfaction of class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 September 2019 Resolved
11104- Retro-reflective material should be fitted on the bottom of lifeboats and rescue boats which are not self-righting. the retro-reflective tape on the bottom of the rescue boat was painted over. 74SOLAS(14)III/32.2 LSA CODE 1.2.3 RES.A. 658(16)ANNEX 1/1.3 50 A.C.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2019
Resolution: Class sent in report stating crew replaced retroreflective tape to satisfaction of class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.