MAURY USCG vessel records Sign in
← All vessels

THE AMIGO

THE AMIGO is a 2012 tank ship. The Coast Guard has recorded 44 inspections since 2014, most recently in August 2026, along with 15 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 2014 to 2026. Most recent: inspection, 6 August 2026.

Built
2012
Last inspected
6 August 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9492309 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1223001
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1223001

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (2014–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10866 - Convention (Subpart B), Gross Ton
14911 - Dead Weight, Metric Ton
21282 - Displacement, Metric Ton
3612 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

6 August 2026 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8456886
15 August 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8210412
30 July 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8198669
2 July 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8172948
24 November 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8039199
16 August 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7977750
23 August 2022 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7541566
13 August 2022 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7532586
11 July 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7503326
14 June 2022 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7477140
18 April 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7433148
17 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7413713
29 July 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7271717
5 July 2021 COC-CHEM Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7245812
20 May 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6956670
7 May 2020 COC-CHEM & TVE Annual
Type not classified · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6949640
24 April 2020 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6944703
18 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6940763
30 January 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6902340
24 January 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6895278
23 April 2019 COC-CHEM & TVE Renew
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6666109
4 March 2019 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6636085
18 January 2019 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6612220
28 December 2018 COE-Administrative · Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6603488
27 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6603162
24 September 2018 COE-Dockside · ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6547087
5 July 2018 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6468003
5 May 2018 Administrative Inspection · Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6401759
3 October 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6280298
21 August 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6247610
16 May 2017 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6170439
21 February 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6091754
1 February 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081059
24 January 2017 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6076047
18 January 2017 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6071503
29 October 2016 COE-Dockside
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6031319
26 September 2016 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6003479
12 August 2016 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5970890
23 May 2016 COE-Administrative
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5884679
12 April 2016 COE-Dockside
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5851558
9 March 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5829812
5 March 2016 Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5827477
13 January 2016 ISPS II Exam · COC-CHEM & TVE Renew · COE-Dockside · Deficiency Check · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5793917
26 March 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4820668

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 July 2025 Resolved
No electrical equiptment shall be installed in any space where flammable mixtures are liable to collect... unles the Administration is satisfied that such equiptment is... appropriately cetified for safe usage in the dusts, vapors, or gases likely to be encountered. PSCO's observed 05 EX proof light fixtures with severely damaged casings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2025
Resolution: Vessel conducted safe repair of all boserved damaged EX proof light fixture casings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported to the USCG that the vessel's main engine servo pump failed causing an inability for the main engine to maintain the desired RPM. Vessel must ensure the main engine servo pump is repaired/replaced, operating properly, and the main engine is operating satisfactorily maintaining the desired RPM for safe navigation prior to transiting beyond breakwater on the Delaware Bay.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 August 2022
Resolved 29 August 2022
Resolution: Recieved Class Report attesting to proper operation of the main engine
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported servo pump was out of order due to clogged orifice. Provide report from classification society attesting to causative factors and continued fitness for service.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 August 2022
Resolution: Received survey statement attesting to repair carried out by ship's force.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2022 Resolved
On voyages of less than 96 hours, an NOA must be submitted before departure, but at least 24 hours prior to entry. Vessel failed to properly submit NOA prior to entry to Sector SENE COTP Zone, from previous port of Baltimore, MD
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 April 2022
Resolved 18 April 2022
Resolution: PSCO informed vessel of reporting requirements. Vessel submitted eNOA prior to departure.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 April 2019 Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. The rescue boat was stowed improperly causing the crew to take 30 minutes to make it ready for launch. 74 SOLAS (2014) CH III, REG 14.1
Action required: 10 - Deficiency Rectified
Resolved 23 April 2019
Resolution: Vessel crew made rescue boat ready for launch.
Lifesaving › Lifeboat › Propulsion Engine
Issued 5 May 2018 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. The vessel's lifeboat engine cannont operate for 5 minutes after starting. 74 SOLAS (14) III/34; LSA Code 4.4.6.3.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2018
Resolution: Vessel's engineering crew identified a failure of the throttle control spring for the freefall lifeboats marine engine as causing the engine to be unable to maintain operation for 5 minutes. Repairs made, 3 starts perfomed, and engine run for 5 minutes.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 January 2017 Resolved
After any survey of the ship, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey withou the sanction of the Administration, except the direct replacement of such equipment and fittings. PSCO found temporary repairs made to the oily water separator filter tank without reporting to the vessel's class or Flag Administration.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 February 2017
Resolved 21 February 2017
Resolution: Received Class report attesting to the repairs to the OWS. Refer to report added to the documentation section.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 January 2017 Resolved
The fire detection and fire alarm system shall be kept in good working order. PSCO discovered 02 of the 06 smoke detectors tested in the engine room were inoperable, one in the purifier room and one in the boiler space. 74 SOLAS (14)II-2/14.2.1.1.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 February 2017
Resolved 1 February 2017
Resolution: Received class report that 02 smoke detectors have been replaced and in good order. See class report for further information.
Engineering › Fuel Oil Service System › Piping
Issued 18 January 2017 Resolved
The probability of ignition, a means shall be provided to control leaks of flammable liquids. PSCO discovered a fuel leak on the heavy fuel oil line in the purifier room at the flange leading to the boiler. 74 SOLAS (14)II-2/14.1 Code 50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2017
Resolved 1 February 2017
Resolution: Received class report stating the leaking flange was replaced and found in good working order. See class report for further information.
Lifesaving › Rigid Liferafts › Hydrostatic Release Unit
Issued 18 January 2017 Resolved
At all times during voyage all life saving arrangements shall be ready for immediate use. Starboardside liferaft found intentionally secured to deck by crew before entering heavy seas. 74 SOLAS (14)III/20.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2017
Resolved 18 January 2017
Resolution: Liferaft was untied, rectified on the spot.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 18 January 2017 Resolved
The safety management system should ensure compliance with mandatory rules and regulations. Oily water seperator found damaged in November. Generator #3 is inoperable during current voyage. Company has been notified but no reports made to Flag/Class. ISM Code 1.2.3
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 18 January 2017
Resolution: Flag/Class notified of equipment failure. Rectified on the spot.
Deck/Cargo › Cargo Stowage › General
Issued 13 January 2016 Resolved
1000 - Alarms - The high level alarm required must alarm before the tank overfill alarm, but no lower than 95 percent of tank capacity. The vessel high level alarms were not in working order at the time of inspection. Alarms must be working prior to taking on cargo. 33CFR 39.20-3/ IBC 15.19.4: Action a.c.
Due 13 January 2016
Resolved 15 January 2016
Resolution: Received Class report attesting to repairs made to the high level alarms. Report attached to activity.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 26 March 2014 Resolved
1840- A chemical tanker shall comply with the requirements of the IBC. Ships carrying toxic or flammable products or both shall be equipped w/ at least 2 instruments designed and calibrated for testing the specific vapors in question. The vessel only has one portable instrument on board and it is unable to test for H2S. SOLAS 09 VII/10.1 IBC Code 13.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2014
Resolved 27 March 2014
Resolution: The vessel purchased a 2nd portable gas meter so 2 were on board. After reviewing the manufacturer guide, the C/O realized he was not performing the calibration test properly on the first instrument. PSCO witnessed sat test of both instruments.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 26 March 2014 Resolved
0220-Masters and any person w/ immediate responsibility for loading, discharging, cleaning of cargo tanks on chemical tankers shall hold a certificate in advance training for chemical tankers. The master only has advanced training for oil tankers. The vsl is not authorized to carry MARPOL Annex II cargoes list on the CoF until the master provides proof of training and endorsement for chem. tankers
Due 26 April 2014
Resolved 13 January 2016
Resolution: The current Master onboard held an advance training for chemical tankers certificate.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 26 March 2014 Resolved
1099-When Table 1 refers to this section or requires a cargo to have a closed gauging system, the cargoes containment must have a high level alarm that can be seen and heard where the cargo transfer is controlled and the open deck. The vsl does not have a audible or visual high level alarm on deck. 46 CFR 153.409
Condition: Improper/Lack of Maintenance
Due 26 April 2014
Resolved 27 March 2014
Resolution: The vsl received replacement parts and installed high level alarm indicator on deck. Alarm satisfactorily tested.

Ownership record