← All vessels
TBC PROGRESS
TBC PROGRESS is a 2012 freight ship. The Coast Guard has recorded 18 inspections since 2014, most recently in January 2025, along with 43 deficiencies and 4 operational controls.
Records from 2014 to 2025. Most recent: inspection, 28 January 2025.
- Built
- 2012
- Last inspected
- 28 January 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 43 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9489821 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FKB2
1223040
Flag
PANAMA
—
Maury page id
psix-1223040
Inspections, by type
…with no type recorded2
Years with a record
9 calendar years (2014–2025)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19999 - Convention (Subpart B), Gross Ton
31966 - Dead Weight, Metric Ton
40376 - Displacement, Metric Ton
10443 - Convention (Subpart B), Net Ton
31966 - Dead Weight, Metric Ton
40376 - Displacement, Metric Ton
10443 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
28 January 2025
PSC B · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8070167
22 January 2024
Appeal
Administrative · Commandant (CG-CVC) · Activity 7852435
6 November 2023
PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7820736
26 October 2023
Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7814626
19 June 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7718311
12 May 2023
Deficiency Check · ISM Exam · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7682745
7 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7682770
28 August 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7545073
12 August 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7266858
5 May 2020
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6948577
4 May 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6948256
4 May 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6990457
16 July 2018
NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6480927
28 March 2018
NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6380694
10 February 2018
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6353091
5 February 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348776
24 February 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5820720
1 June 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4874080
Deficiency record · 43
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 January 2025
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed fore peak water ingress alarm not functional.
74 SOLAS 20 I/II(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2025
Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed pressure water-spraying fire-extinguishing system. PSCO observed water mist local fire pump starter actively leaking. Vessel crew replaced o-ring, tested zone, leaking stopped.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 November 2023
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Objective evidence indicates a lack of compliance with vessel SMS to include proper operation, ready availability and maintenance of fixed fire-fighting systems and appliances, lack of compliance with garbage management plan, insufficient control of oil leaks, and general housekeeping. An external audit is required.
74 SOLAS(20) IX/3.1
ISM Code Part A/10.1
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 November 2023
Resolved
Machinery spaces of category A above 500m3 in volume shall, in addition to the fixed fire-extinguishing system required in paragraph 5.1.1, be protected by an approved type of fixed water- based or equivalent local application fire extinguishing system... In the case of periodically unattended machinery spaces, the fire-extinguishing system shall have both automatic and manual release capabilities... PSCOs discovered an unattended machinery space with the LP water mist system set to "local" preventing the system from operating automatically.
74 SOLAS (20 CONS) II-2/10.5.6.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2023
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the fuel oil shall be such as to ensure the safety of the ship and persons onboard... PSCOs discovered an MGO fuel leak on the distribution system in the fuel supply line for the vessel's boiler and observed fuel dripping onto lagging and pooling on the deck below.
74 SOLAS (20) II-2 / 4.2.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 November 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced... PSCOs discovered 02 CO2 nozzles in engine room covered with duct tape and plastic and 03 labeled extinguisher brackets in the engine room missing portable fire extinguishers.
74 SOLAS (20 CONS) II-2 / 14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids… Means shall be provided to limit the accumulation of flammable liquids. PSCOs observed oil-soaked rags and active oil leaks on M/E.
74 SOLAS (20 CONS) II-2 / 4.1.1
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 November 2023
Resolved
Every ship of 100 gross tonnage and above...shall carry a garbage management plan which the crew shall follow... PSCOs observed inadequate containers and improper storage of garbage to include oily rags and domestic waste mixed with large batteries in the same wooden container. Additionally, oily rags, oil-soaked cardboard, and flammable liquid containers were found stored behind a lube oil tank, and throughout engine room.
MARPOL ANNEX V / 10.2
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 November 2023
Resolved
For determining the appropriate fire integrity standards to be applied to divisions between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (11) below... Table 9.5 requires an A-60 boundary between machinery spaces of category A and spaces for the storage of flammable liquids. PSCOs observed placarded flammable liquid containers in various locations throughout engine room and not in spaces categorized for their storage.
74 SOLAS (20 CONS) II-2 / 9.2.3.3.2.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 November 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Pump marked “fire G/S pump is inoperable”. Vessel has a general service pump and emergency fire pump for firefighting purposes.
74 SOLAS (20 CONS) II-2 / 14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 November 2023
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being determined in accordance with the Fire Test Procedures Code... PSCOs observed an A-15 Fire door on Deck C is being kept open due to loud whistling noise caused by ventilation pushing air through the door frame when door is closed.
74 SOLAS (20 CONS) II-2/ 9.4.2.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 November 2023
Resolved
Satisfactory means for safe passage required by 25-1 (in the form of guard rails, lifelines, gangways or underdeck passages, etc.) shall be provided for the protection of the crew getting to and from their quarters, the machinery space and any other spaces used in the essential operation of the ship. PSCOs observed multiple railings in engine room have missing/broken rails.
ICLL 25.4
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 October 2023
Resolved
07108-FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED EXCESSIVE CORROSION ON THE LINES WHICH SUPPLY THE HYPER MIST NOZZLES WITH WATER TO THE VESSEL'S SEPARATOR ROOM.THE CREW WAS REQUESTED TO DEMONSTRATE THE OPERATION OF THE HYPER MIST SYSTEM IN THIS SPACE. THE CREW ATTEMPTED TO ACTIVATE THE SYSTEM THROUGH THE FIXED FIRE DETECTION AND LOCAL OPERATION FOR OVER 15 MINUTES WITHOUT SUCCESS.
74 SOLAS (20) II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 October 2023
Resolved
07126-MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED EXCESSIVE OIL LEAKS ON THE #1 AND #2 MDG'S AND UNDER THE MAIN ENGINE.
74 SOLAS (20) II-2/4.1.1
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 26 October 2023
Resolved
14108-OIL FILTERING EQUIPMENT REFFERED TO IN PARAGRAPH 2 OF THIS REGULATION SHALL COMPLY WITH PARAGRAPH 6 OF THIS REGULATION. IN ADDITION, IT SHALL BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN THIS LEVEL CANNOT BE MAINTAINED. THE SYSTEM SHALL ALSO BE PROVIDED WITH ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OIL MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT METER OF THE EFFLUENT EXCEEDS 15 PARTS PER MILLION. IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT AND APPROVALS, THE ADMINISTRATION SHALL HAVE REGARDS TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION. THE 15 PARTS PER MILLION BILGE ALARM SHOULD RECORD DATE, TIME AND ALARM STATUS, AND OPERATING STATUS OF THE 15 PART PER MILLION BILGE SEPARATOR. PSCO OBSERVED THE OIL CONTENT METER, OMD-2005, DID NOT PROPERLY INDICATED THE SEPARATOR'S OPERATION STATUS.
MARPOL (73/78) I/14.7 MEPC 107(49) 4.2.9
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 26 October 2023
Resolved
11124-BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED SEVERAL DAMAGED STEPS DAMAGED STEPS ON THE FWD EMBARKATION LADDER. ADDITIONALLY, THE CREW WAS NOT ABLE TO PROVIDE ANY CERTIFICATE OR WEIGH TEST DOCUMENTATION FOR THE FWD EMBARKATION LADDER.
74 SOLAS (20) III/20.2
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 26 October 2023
Resolved
09208-MACHINERY ASSOCIATED PIPING SYSTEMS SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD, DUE REGARDS BEING PAID TO MOVING PARTS AND HOT SURFACES. PSCO OBSERVED MISSING LAGGING ON THE HOT SIDE OF THE TURBO ON #1 MDG.
74SOLAS(20)
II-1/26.1
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 October 2023
Resolved
09210-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED HYDRAULIC LEAKS ON CARGO HOLDS HATCH COVER RAMS #1 AFT STBD, #2FWD STBD, #2 AFT PORT AND #3 FWD PORT.
74SOLAS(20)
III/20.2
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 October 2023
Resolved
11104-BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED THE CREW WAS UNABLE TO START THE RESCUE BOAT FOR OVER 15 MINUTES WITHOUT USE OF TOOLS. THE CREW WAS ABLE TO GET THE RESCUE BOAT STARTED AFTER TROUBLESHOOTING.
74SOLAS(20)
III/20.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 June 2023
Resolved
Doors in boundary bulkheads of machinery spaces of Category A shall be reasonably gastight and self closing. A class door between steering gear and engine room has a bent sill therefore no longer preventing the passage of smoke or flame nor being gas tight.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The STBD aft steering raim is leaking hydraulic oil.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 19 June 2023
Resolved
After any survey of the ship under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arrangement, machinery, equipment, or other items covered by the survey without the sanction of the Adminisitration. PSCO identified fabricated flexible hoses from the main engine fuel oil drains directly into the bilge holding tank. Additionally, vessel is stowing used oil from an oil change conducted on Generator 2 in steel drums in the S/G room.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Emergency fire pump priming tank is wasted and leaking.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 May 2023
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with additional requirements which may be established by the company. Due to the objective evidence in the deficiencies noted below, the vessel is not being maintained and not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel's SMS under the ISM code. An external audit conducted by the Flag or RO is required before the ship will be release from its detention to determine whether the ship is operating in accordance with the ISM code. Provide a copy of the completed audit report to the USCG prior to departure from port. 74 SOLAS 20 XI-1/4.1 ISM Code 10.2
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 May 2023
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 minutes. When testing primary source of power for emergency generator, PSCO observed that the battery bank was not sufficient to start the engine. 74 SOLAS 20 II-1/44.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 May 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed a fault on the fire detection panel in the engine control room. PSCO also observed and the Chief Engineer was aware that the flame and smoke detectors over the number three generator and incinerator space were not operational. 74 SOLAS 20 II-2/14.2.1.2
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 12 May 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. PSCO observed multiple instances of fresh air distribution vents in the engine room severely clogged.
74 SOLAS 20 I/11(a)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 May 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provide to control leaks of flammable liquids. PSCO observed oil-soaked lagging, pumps, and equipment in the engine purifier room and on electrical cables on the ship's main engine. 74 SOLAS 20 II-2/4.1
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 12 May 2023
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed multiple instances of modification to the ventilation ducts to redirect the flow of fresh air into the engine room and on specific machinery. 74 SOLAS 20 I/11(b)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2023
Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO observed one port side and two starboard side valves on deck for the fuel-oil overflow piping system were frozen and in a general state of disrepair. 74 SOLAS 20 II-1/3-1
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliance shall be in working order and ready for immediate use. PSCO observed the hydro-static release unit on both life rafts were installed incorrectly with the painter line attached at the raft release point.
74 SOLAS 20 III/20.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2023
Resolved
Where a fixed gas fire-extinguishing system is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSCO observed the caps to close the non-return valves on the cargo hatch drains were missing from every non-return valve on all of the cargo holds.
74 SOLAS 20 II-2/10.4.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a significant leak on the general saltwater cooling pump for the generators.
74 SOLAS 20 I/11(a)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 May 2023
Resolved
The machinery and fittings shall be of a design and construction adequate for serve for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due to regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed evidence of a jacket water leak on at least 1 of the main engine cylinder heads. 74 SOLAS 20 II-1/26.1
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 May 2023
Resolved
The machinery and fittings shall be of a design and construction adequate for service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due to regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed exposed rotating machinery on number 1 & 2 service generators and evidence of a significant exhaust leak on the ship service generator combine exhaust manifold.
74 SOLAS 20 II-1/26.1
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 May 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed fore peak water ingress alarm not functional.
74 SOLAS 20 I/11(a)
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 12 May 2023
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed fault on ship's VDR due to missing signal from watertight doors.
74 SOLAS 20 I/11(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2023
Resolved
Ships shall be maintained in compliance with the regulations of a classification society which is recognized by the Administration. PSCO observed corrosion/wastage on starboard anchor windlass and both port and starboard anchor chains.
74 SOLAS 20 II-1/3-1
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 May 2020
Resolved
Before ship leaves the port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed 02 temporaty patches on the lower corner of the lifeboat. 74 Solas (14) III/20.2 AC 17
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 28 March 2018
Resolved
The company shall comply with the requirements of the ISM code. Due to objective evidence, the PSCO questions the adequacy of the vessel's SMS and Company Procedures Manual. The Company is responsible for the purchase and arrangements of provisions. Provisions were found to be inadequate and not provided for after requested verbally and by email from the vessel's officers. An external audit is recommended to be conducted by the flag state or recognized organization.
Lifesaving › Lifeboat › Propulsion Transmission
Issued 5 February 2018
Resolved
0610: BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. FREE-FALL LIFEBOAT TRANSMISSION CLUTCH IS FAILING TO ENGAGE, RESULTING IN LACK OF PROPULSION AND INABILITY OF EQUIPMENT TO FUNCTION FOR IMMEDIATE USE. (74 SOLAS (14) III/2) CODE: 17(a)(c)
Engineering › Freshwater System (intermediary cooling) › Valve
Issued 5 February 2018
Resolved
1499: THE MACHINERY, ASSOCIATED PIPING SYSTEMS, AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENTED. LEAKING AND CORROSION WERE FOUND ON SEALS IN THE FRESH WATER GENERATOR SYSTEM, GENERATOR COOLING WATER PUMP AND PIPING, AND LUBE OIL VENT LINE. (74 SOLAS (14) II-1/26.1) CODE: 40(a)(c)
Fire Fighting › Nozzles › Condition
Issued 5 February 2018
Resolved
0725:FIRE PROTECTION SYSTEMS AND APPLIANCES SHALL BE MAINTAINED AND READY FOR USE. TWO SPRINKLER HEADS FOR THE FIXED FIREFIGHTING SYSTEM IN THE ENGINE ROOM WERE FOUND COVERED AND THUS NOT READY FOR IMMEDIATE USE. (74SOLAS(14) II-2/14.1.1) CODE:10(c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.