← All vessels
ARUNA NAZIK
ARUNA NAZIK is a 2012 freight ship. The Coast Guard has recorded 8 inspections since 2021, most recently in July 2024, along with 13 deficiencies and 4 operational controls.
Records from 2021 to 2024. Most recent: inspection, 11 July 2024.
- Built
- 2012
- Last inspected
- 11 July 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9583146 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A6025
1223186
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1223186
Inspections, by type
…with no type recorded1
Years with a record
3 calendar years (2021–2024)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it32305 - Simplified, Gross Ton
19458 - Simplified, Net Ton
32305 - Convention (Subpart B), Gross Ton
19458 - Convention (Subpart B), Net Ton
58097 - Dead Weight, Metric Ton
67802 - Displacement, Metric Ton
19458 - Simplified, Net Ton
32305 - Convention (Subpart B), Gross Ton
19458 - Convention (Subpart B), Net Ton
58097 - Dead Weight, Metric Ton
67802 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
11 July 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7955399
1 July 2024
ISM Exam · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7946180
29 June 2024
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7944977
29 June 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7955150
7 February 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7861890
14 September 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7788357
21 January 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7127969
8 January 2021
PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7121523
Deficiency record · 13
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 11 July 2024
Resolved
Except as provided in regulations I/7(b)(ii), I/8 and I/9, while all reasonable steps shall be taken to maintain the equipment required by this chapter in efficient working order, malfunctions of that equipment shall not be considered as making the ship unseaworthy or as a reason for delaying the ship in ports where repair facilities are not readily available, provided suitable arrangements are made by the master to take the inoperative equipment or unavailable information into account when planning and executing a safe voyage to a port where repairs can take place. PSCO observed expired VDR DCU batteries and beacon battery.
74SOLAS(20) V/16.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 July 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed 03 empty fire hose containment boxes. Tested all fire hoses, two out of five were found leaking. Missing and leaking hoses were replaced and all were operational.
74SOLAS(20) II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 11 July 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed uncharged EEBDs. Crew re-charged EEBD, meeting minimum requirements.
74SOLAS(20) II-2/14.2.1.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 July 2024
Resolved
15109 - The company and the ship shall comply with the requirements of the International Safety Management code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting with the requirements, the company should ensure that any nonconformity is reported, with possible cause, if known. The nature of the below deficiencies provides objective evidence of serious failure of the implementation of the ISM Code. The nonconformities observed by CG PSCE in main engine, steering, and generator systems are not accurately reflected on the vessel’s SMS log/checklist. The SMS checklist used prior to coming into port on 29JUN2024 reported zero deficiencies on all systems mentioned. An external ISM audit report is recommended. 74 SOLAS (20) IX/3.1 - ISM Code Part A/10.1 – 30ABC
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 July 2024
Resolved
07126 - To prevent the ignition of combustible materials or flammable liquids, means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaks from diesel generators #1, #2, #3, resulting in oil accumulating in the fly wheel pan. Observed fuel oil dripping onto starting motor of the main engine. Area surrounding starting motor was found with oil sprayed on surface. Excessive leaks from the main engine and diesel generators 1, 2, and 3 present a fire risk due to exposed flammable/combustible liquids. In aggravation, crewmembers were observed smoking in various engineering spaces, contrary to Masters verbal instructions. 74 SOLAS (09) II-2/4.1.1 – 30ABC
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 July 2024
Resolved
07126 - In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapors. Lagging in the engine room and oil purifier space was soaked in oil, creating a fire hazard. 74 SOLAS (09) II-2/4.4.3 - 17AC
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 July 2024
Resolved
02105 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit top proceed to sea without danger to the ship or person on board. The steering gear system was found with multiple excessive hydraulic oil leaks. Steering gear local controls were found leaking hydraulic oil resulting in oil pooling in the aft steering room 74 SOLAS (20) I/11 – 17AC
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 July 2024
Resolved
01315 - Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page shall be signed by the Master of the ship. The Oil Record Book from 23MAY24 to 12JUN24 is missing the vessel Master’s signature. MARPOL Annex I/17.4 – 16AC
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 July 2024
Resolved
02105 - Hydraulic power-operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. Reservoir tank was found low due to leakage, not having enough oil for one system. S. 74 SOLAS (20) II-1/ 29.12.3 – 10C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2024
Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. While mooring in Port Canaveral, FL, the M/E failed to respond to dead slow astern. 74 SOLAS (20) II-1/28.1 17AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2024
Resolved
The condition of the ship shall be maintained to ensure it will remain fit to proceed to sea w/o danger to the ship or persons on board. There is an oil leak on M/E cylinder #2. Addtionally, PSCO found a jacket water leak on M/E cylinder #1 and a small water leak on cylinder of generator #3. 74 SOLAS (20)/11(a) - 17AC
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 June 2024
Resolved
Ships shall be provided with fire pumps complying with the requirements of this regulation. Vessels "fire/bilge pump" is leaking excessively at the gland. 74 SOLAS (20)/10.2 - 16AC
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 January 2021
Resolved
TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS A MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.NUMBER THREE GENERATOR WAS DISCOVERED WITH A FUEL OIL LEAK. 74 SOLAS 09 II-2/4.1.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.