MAURY USCG vessel records
← All vessels

ARUNA NAZIK

ARUNA NAZIK is a 2012 freight ship. The Coast Guard has recorded 8 inspections since 2021, most recently in July 2024, along with 13 deficiencies and 4 operational controls.

Records from 2021 to 2024. Most recent: inspection, 11 July 2024.

Built
2012
Last inspected
11 July 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9583146
V7A6025
1223186
Flag
MARSHALL ISLANDS
Maury page id
psix-1223186

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2021–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it32305 - Simplified, Gross Ton
19458 - Simplified, Net Ton
32305 - Convention (Subpart B), Gross Ton
19458 - Convention (Subpart B), Net Ton
58097 - Dead Weight, Metric Ton
67802 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 8

11 July 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7955399
1 July 2024 ISM Exam · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7946180
29 June 2024 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7944977
29 June 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7955150
7 February 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7861890
14 September 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7788357
21 January 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7127969
8 January 2021 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7121523

Deficiency record · 13

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 11 July 2024 Resolved
Except as provided in regulations I/7(b)(ii), I/8 and I/9, while all reasonable steps shall be taken to maintain the equipment required by this chapter in efficient working order, malfunctions of that equipment shall not be considered as making the ship unseaworthy or as a reason for delaying the ship in ports where repair facilities are not readily available, provided suitable arrangements are made by the master to take the inoperative equipment or unavailable information into account when planning and executing a safe voyage to a port where repairs can take place. PSCO observed expired VDR DCU batteries and beacon battery. 74SOLAS(20) V/16.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2024
Resolution: PSC NOLA received a technician’s report from MACKAY MARINE satisfying the requirement
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 July 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed 03 empty fire hose containment boxes. Tested all fire hoses, two out of five were found leaking. Missing and leaking hoses were replaced and all were operational. 74SOLAS(20) II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Due 11 July 2024
Resolved 11 July 2024
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 11 July 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed uncharged EEBDs. Crew re-charged EEBD, meeting minimum requirements. 74SOLAS(20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 July 2024
Resolved 11 July 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 July 2024 Resolved
15109 - The company and the ship shall comply with the requirements of the International Safety Management code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting with the requirements, the company should ensure that any nonconformity is reported, with possible cause, if known. The nature of the below deficiencies provides objective evidence of serious failure of the implementation of the ISM Code. The nonconformities observed by CG PSCE in main engine, steering, and generator systems are not accurately reflected on the vessel’s SMS log/checklist. The SMS checklist used prior to coming into port on 29JUN2024 reported zero deficiencies on all systems mentioned. An external ISM audit report is recommended. 74 SOLAS (20) IX/3.1 - ISM Code Part A/10.1 – 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 1 July 2024
Resolved 7 July 2024
Resolution: Audit conducted all items corrected. SMC endorsed 4 July, 2024.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 July 2024 Resolved
07126 - To prevent the ignition of combustible materials or flammable liquids, means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaks from diesel generators #1, #2, #3, resulting in oil accumulating in the fly wheel pan. Observed fuel oil dripping onto starting motor of the main engine. Area surrounding starting motor was found with oil sprayed on surface. Excessive leaks from the main engine and diesel generators 1, 2, and 3 present a fire risk due to exposed flammable/combustible liquids. In aggravation, crewmembers were observed smoking in various engineering spaces, contrary to Masters verbal instructions. 74 SOLAS (09) II-2/4.1.1 – 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 1 July 2024
Resolved 7 July 2024
Resolution: All oil leaks that were observed have been corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 July 2024 Resolved
07126 - In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapors. Lagging in the engine room and oil purifier space was soaked in oil, creating a fire hazard. 74 SOLAS (09) II-2/4.4.3 - 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2024
Resolved 7 July 2024
Resolution: Insulation replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 July 2024 Resolved
02105 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit top proceed to sea without danger to the ship or person on board. The steering gear system was found with multiple excessive hydraulic oil leaks. Steering gear local controls were found leaking hydraulic oil resulting in oil pooling in the aft steering room 74 SOLAS (20) I/11 – 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2024
Resolved 7 July 2024
Resolution: Hydraulic leaks on steering system were fixed.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 July 2024 Resolved
01315 - Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page shall be signed by the Master of the ship. The Oil Record Book from 23MAY24 to 12JUN24 is missing the vessel Master’s signature. MARPOL Annex I/17.4 – 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2024
Resolved 7 July 2024
Resolution: Entries updated.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 July 2024 Resolved
02105 - Hydraulic power-operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. Reservoir tank was found low due to leakage, not having enough oil for one system. S. 74 SOLAS (20) II-1/ 29.12.3 – 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 July 2024
Resolved 1 July 2024
Resolution: Vessels crew added more hydraulic oil to the resevoir tank to the required minimum level for the steering gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2024 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. While mooring in Port Canaveral, FL, the M/E failed to respond to dead slow astern. 74 SOLAS (20) II-1/28.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2024
Resolved 7 July 2024
Resolution: Repairs made to the MDE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2024 Resolved
The condition of the ship shall be maintained to ensure it will remain fit to proceed to sea w/o danger to the ship or persons on board. There is an oil leak on M/E cylinder #2. Addtionally, PSCO found a jacket water leak on M/E cylinder #1 and a small water leak on cylinder of generator #3. 74 SOLAS (20)/11(a) - 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2024
Resolved 7 July 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 June 2024 Resolved
Ships shall be provided with fire pumps complying with the requirements of this regulation. Vessels "fire/bilge pump" is leaking excessively at the gland. 74 SOLAS (20)/10.2 - 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2024
Resolved 7 July 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 January 2021 Resolved
TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS A MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.NUMBER THREE GENERATOR WAS DISCOVERED WITH A FUEL OIL LEAK. 74 SOLAS 09 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 21 January 2021
Resolution: Received documentation showing deficiency was rectified (see documents tab)

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.