MAERA is a 2013 freight ship. The Coast Guard has recorded 3 inspections since 2018, most recently in February 2025, along with 7 deficiencies and 1 operational control.

Records from 2018 to 2025. Most recent: inspection, 18 February 2025.

Built
2013
Last inspected
18 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 February 2025
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9563677
1223202
Flag
MARSHALL ISLANDS
Maury page id
psix-1223202

Documentation record

Tonnage as PSIX records it41342 - Convention (Subpart B), Gross Ton
25325 - Convention (Subpart B), Net Ton
75403 - Dead Weight, Ton
88536 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

18 February 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8073739
3 November 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7337261
9 August 2018 Ballast Water Examination · ISM Exam · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6505695

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2021 Resolved
ALL STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND REILABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED HYDRAULIC OIL LEAK FROM AIR PURGE LINE. 74 SOLAS (14)/ II-1/29.2.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 3 November 2021
Resolved 3 November 2021
Resolution: Engineering crew demonstrated operational readiness of ships steering gear
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 August 2018 Resolved
FIRE PROTECTION SYSTEMS AND FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE PROPERLY TESTED AND INSPECTED. PSCO DISCOVERED THE LEAK/ALARM PRESSURE SWITCH ON THE DISCHARGE SIDE OF THE CO2 SYSTEM LOCATED IN THE CO2 ROOM DISCONNECTED. VESSELS ELECTRICIAN ATTEMPTED TO TEST THE SWITCH AND WAS UNSUCCESSFUL. IN ADDITION THE SHIP SERVICE AIR LINE WAS FOUND ATTACHED TO THE DISCHARGE SIDE OF THE SYSTEM IN THE CO2 ROOM, WHICH IN THE EVENT OF CHARGING THE CO2 SYSTEM COULD RUPTURE THE HOSE OR BACKFILL THE SHIP SERVICE AIR LINE. CREW COULD NOT PRODUCE INTERVAL INSPECTIONS OF THE SPACE. 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2018
Resolution: RECEIVED CLASS REPORT FROM BV AND SERVICING REPORT FROM HIGH SEAS TRADING COMPANY. CONFIRMED DEFICIENCIES HAVE BEEN RECTIFIED.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2018 Resolved
74 SOLAS (14) II-2/4.2.3.1 THE ARRANGEMENTS MADE IN MACHINERY SPACES OF CATEGORY A SHALL AT LEAST COMPLY WITH THE PROVISIONS OF PARAGRAPH 2.2.3.5. SAFE AND EFFICIENT MEANS OF ASCERTAINING THE AMOUNT OF OIL FUEL CONTAINED IN ANY OIL FUEL TANK SHALL BE PROVIDED. PSCO DISCOVERED MULTIPLE HYDRAULIC OIL TANK GAUGES SELF CLOSING VALVES PERMANENTLY SOLDERED IN THE OPEN POSITION WHICH WOULD ALLOW THE FLUID TO ESCAPE IF RUPTURED. 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2018
Resolution: RECIEVED CLASS REPORT CONFIRMING REPAIR OF SIGHT GLASSES AND FUNCTIONAL TESTS.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 10 August 2018 Resolved
74SOLAS(14)1/11.A THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO DISCOVERED INCENDERARY BRICK COLLAPSED INSIDE THE SHIPS INCINERATOR. VESSEL BURNS SLUDGE AND GARBAGE AT REGULAR INTERVALS. 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2018
Resolution: RECIEVED SATISFACTORY CLASS REPORT ATTESTING TO REPAIRED REFRACTORY MATERIAL INSIDE INCINERATOR.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 August 2018 Resolved
74 SOLAS (14)ii-2/4.2.2.3.4 OIL FUEL PIPES, WHICH IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM A STORAGE, SETTLING OR DAILY SERVICE TANK HAVING A CAPACITY OF 500L AND ABOVE SITUATED ABOVE THE DOUBLE BOTTOM, SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE CONCERNED IN THE EVENT OF A FIRE OCCURING IN THE SPACE IN WHICH THE TANKS ARE SITUATED. PSCO DISCOVERED A HOLD BACK DEVICE ON THE QUICK CLOSING VALVE FROM MGO DAY TANK SERVICING THE SHIP SERVICE GENERATORS AND BOILER. 30ABC
Action required: 30 - Ship detained
Resolved 12 August 2018
Resolution: RECEIVED SATISFACTORY CLASS REPORT ATTESTING TO REMOVAL OF HOLDBACK AND TESTING OF QUICK CLOSING VALVES.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 August 2018 Resolved
74SOLAS(14)II-2/4.2.2 IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD AND SHALL AT LEAST COMPLY WITH THE FOLLOWING PROVISIONS. PSCO DISCOVERED AN ACTIVE FUEL LEAK ON THE NO. 1 CYLINDER HIGH PRESSURE FUEL PUMP AT A RATE OF 02 LITERS PER MINUTE. 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 August 2018
Resolution: RECEIVED SATISFACTORY CLASS REPORT ATTESTING TO REPAIR OF FUEL PUMP PUNCTURE VALVE. FLANGES WERE ALSO TAPED.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 9 August 2018 Resolved
74 SOLAS (14) IX/3.1 ISM CODE(14)11.3 THE COMPANY AND SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE ISM CODE. THE DOCUMENTS USED TO DESCRIBE AND IMPLEMENT THE SAFETY MANAGEMENT SYSTEM MAY BE REFERRED TO AS THE SAFETY MANAGEMENT MANUAL. DOCUMENTATION SHOULD BE KEPT IN A FORM THAT THE COMPANY CONSIDERS MOST EFFECTIVE. EACH SHIP SHOULD CARRY ON BOARD ALL DOCUMENTATION RELEVANT TO THE SHIP. IN REGARD TO THE DEFICIENCIES DISCOVERED DURING THIS EXAM AND DUE TO THE LACK OF KNOWLEDGE, PROCEDURES AND LOGS OF THE CREW, PSCO HAS USED NVIC 04-05 TO CONDUCT AN EXPANDED ISM EXAM. THE VESSELS MASTER AND [name withheld] TO PRODUCE RELEVANT PORTIONS OF THE SHIPS SMS IN REGARDS TO ALL LISTED ON THE USCG FORM 5437-B. BOTH WERE UNABLE TO PRODUCE THE REQUIRED FORMS AND POLICY PROCEDURES OVER A THREE HOUR TIME PERIOD. RECCOMEND AN EXTERNAL AUDIT TO INCLUDE PROFICIENCY IN KNOWLEDGE, TRAINING AND IMPLEMENTATION ON THE SHIP'S SMS. 17AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2018
Resolution: RECIEVED THIRD PARTY ISM AUDIT CONFIRMING MULTIPLE NONCONFORMITIES. NOTED: It was agreed with the Company to carry out additional verification audit for effective implementation of corrective actions for NCNs issued now within 2 months - by 10 Oct 2018.

Ownership record