Records from 2016 to 2025. Most recent: inspection, 22 July 2025.
Inspection history · 18
22 July 2025
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8183317
31 January 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8073028
11 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7956075
17 May 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7689853
27 February 2023
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7643523
12 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7429427
16 July 2021
Deficiency Check · Annual Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7258306
3 February 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7141997
17 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011311
6 August 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6774349
29 January 2019
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6617022
22 May 2018
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6408874
1 February 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351815
22 August 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6248408
30 January 2017
Hull Examination · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6079943
25 October 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6030994
7 September 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5994816
26 July 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5953495
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed engine compartement with fireboy installed is not vapor tight.
46 CFR 176.830
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 7 August 2025
Resolution: engine compartment sealed with fire resistant foam
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2025
Resolved
A portable hand bilge pump must be Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. MI observed hand bilge pump not operable.
46 CFR 182.520 (b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 7 August 2025
Resolution: obtained new hand bilge pump
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 May 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel did not have means to secure ventilation to the engine room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2023
Resolution: Received evidence that engine ventilation covers were repaired and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin and Eye wash expired in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2023
Resolution: Received evidence that expired items of first aid kit are onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2023
Resolution: Received evidence that child lifejackets are stowed separately from adult lifejackets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 August 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Visual alarm was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 21 October 2021
Resolution: Photo evidence of visual alarm working received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2021
Resolved
Ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel's name marking was faded and worn on ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 21 October 2021
Resolution: Photo evidence of repaired block lettering received.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2020
Resolved
A small passenger vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of radio installations by a FCC License Technician. Vessel did not have a current/valid Radio Telephony Certificate. Vessel must complete Compulsory Inspection and provide evidence of current radio safety certificate onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 14 August 2020
Resolution: Recieved pictures, all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2020
Resolved
A documented vessel must have the current, original Certificate of Documentation onboard. Vessel is awaiting COD from NVDC. Provide evidence of current COD onboard
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 31 August 2020
Resolution: Recieved notice of valid COD after issues with application for renewal with NVDC, all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2019
Resolved
Emergency fuel shutoff valve lettering is faded
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2019
Resolution: Relabled the system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2019
Resolved
Bonding wire broken off connection in steering compartment
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2019
Resolution: Replaced wire.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2019
Resolved
Fire extenguisher was not recently serviced
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2019
Resolution: Replaced with an upto date fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 August 2019
Resolved
CO2 system automatic engine shutdown inoperable
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: CO2 system automatic engine shutdown tested operable.
Communications › Audible Communications › Horn/Whistle
Issued 4 October 2017
Resolved
Repair vessels installed sound signaling device and make operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 1 February 2018
Resolution: Sound signal made fully operational; test sat.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 4 October 2017
Resolved
Repair vessels common grounding cable connections in the Backing Rudder Space and the PORT thru hull connection for Bilge OVBD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 1 February 2018
Resolution: Common grounding cable connections secured.
Electrical › Electric Generation Source (service) › Panelboard
Issued 4 October 2017
Resolved
Properly label the main 12vdc panelboard for the circuits used.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 1 February 2018
Resolution: 12vdc panelboard properly labeled.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 1 August 2016
Resolved
Ground wire for both fuel fills need proper ground location installation on both ends of fuel fill.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: Tanks properly grounded.
Engineering › Generator (propulsion/auxiliary-electric) › Battery Charging Circuitry
Issued 1 August 2016
Resolved
Label bottom 12 V control panel for active and spares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: Panel labeled
Communications › Audible Communications › Horn/Whistle
Issued 1 August 2016
Resolved
Have horn at upper operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: Horn provided.
Engineering › Bilge Water Management System › Pump
Issued 1 August 2016
Resolved
Label both bilge pumps for location and fix eng room bilge switch light has to come on.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: Bilge pump indicators labled and tested.
Navigation › Piloting/Steering › Marine Charts
Issued 1 August 2016
Resolved
Update charts coast pilot light list tides-currents and notice to Mariners marine broadcast.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 October 2016
Resolution: Updated charts were provided.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 1 August 2016
Resolved
Anchor light not visible from all areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: New anchor light installed where visible from 360 degrees.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 August 2016
Resolved
COI not available for signature.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: COI on board.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 1 August 2016
Resolved
Emergency broadcast placard unreadable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: New placards provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 August 2016
Resolved
Water light for life ring battery expired 9-15 replace with proper battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2016
Resolved 7 September 2016
Resolution: New battery installed.