MAURY USCG vessel records
← All vessels

NAVE AQUILA

NAVE AQUILA is a 2012 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in August 2025, along with 3 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 21 August 2025.

Built
2012
Last inspected
21 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 August 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9459072
1223551
Flag
PANAMA
Maury page id
psix-1223551

Documentation record

Tonnage as PSIX records it30067 - Convention (Subpart B), Gross Ton
13255 - Convention (Subpart B), Net Ton
60926 - Displacement, Ton
49991 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

21 August 2025 Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8213643
7 January 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8059760
19 August 2024 PSC B · COC-CHEM Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7980422
18 August 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7983992
24 November 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7829084
8 August 2023 COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7760660
21 July 2021 PSC B · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7248507
8 August 2019 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6777018
27 May 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6692410
4 May 2018 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6405501
4 October 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6278889
6 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5993024
2 September 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5990276

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 May 2019 Resolved
74 SOLAS (2009) II-2/11.6.1 The venting arrangements shall be so designed and operated as to ensure that neither pressure nor vacuum in cargo tanks shall exceed design parameters and be such as to provide for small and large volumes of vapour. PSCO noted the pressure relief valve serving tank # 1 Port, #2 Port and #3 Starboard were stuck in the closed position and the crew were unable to demonstrate free movement of the pressure release until the completed maintinance to free the ball from the seat.
Action required: 10 - Deficiency Rectified
Due 27 May 2019
Resolved 27 May 2019
Resolution: Corrected on the spot.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 27 May 2019 Resolved
MARPOL 1/6.4.1 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting a threat. PSCO noted incinerator secondary burner inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 August 2019
Resolution: Received e-mail w/ scanned NKK classification society survey report #19PX0131. Survey report states: Vessel's company provided 2 new diesel oil burner motors for the waste oil incinerator, repair carried out by ship's crew to the satisfaction of class.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 27 May 2019 Resolved
74 SOLAS (2014) 1/11 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship remains fit to proceed to sea without danger to ship or persons onboard. PSCO discovered leaking hydraulic coupling serving aft mooring winch.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 August 2019
Resolution: Received e-mail with scanned NKK classification society survey report #19PS0437. Survey report states: Vessel's company supplied spare part (O-ring) of hydraulic oil line in S/G room and operation test was carried out with satisfactory results.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.