Records from 2016 to 2026. Most recent: inspection, 4 May 2026.
Documentation record
Registered dimensions (L × B × D)184.3 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)184.3 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,158 / net 347
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 August 2025 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
1158 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
347 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
4 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8345773
30 January 2025
COI Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8072271
9 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7908974
3 February 2023
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7632987
20 January 2023
Cargo Tank Internal · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7624718
3 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7442691
13 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7195569
5 February 2020
Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6903118
23 April 2019
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6668236
19 January 2018
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6340236
12 January 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6336775
4 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6138974
21 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5842652
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 January 2025
Resolved
Unless one or more extensions are authorized by the Commandant (CG-CVC), each OSV must be placed in drydock or hauled out for examination twice each 5 years with no interval between examinations exceeding 3 years. Rectify the Following repairs:
1. Excessive wastage on escape trunk handle STBD side
2. bulwarks openings on 02 deck near bits higher than 9 inches; raise chain guard
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2025
Resolution: Repairs to trunk handle and addition of chain to bulwark opening completed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 May 2024
Resolved
Each fire station must have one lenght of fire hose. The vessel was four fire hoses short, which must be replaced with compliant fire hoses.
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Four (04) fire stations were fitted with new fire hoses that comply with 46CFR34.10-10.
14 - Pollution Prevention › N/A - No Subsystem › VGP: Annual Report
Issued 9 May 2024
Resolved
The vessel must submit to EPA annual VGP reports. The last VRP report onboard the vessel was from 2019. Vessel must provide evidence of annual reports between year 2020 and 2024.
40CFR Part 122.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 10 June 2024
Resolution: Vessel submitted VGP annual report.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 May 2024
Resolved
Each EPIRB must be tested monthly. Checked vessels logs and found that EPIRB test was not done in January, February, and May.
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Vessel master demonstrated to CG inspectors an EPIRB test, and logged in ship's rough log.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 May 2024
Resolved
A fire drill must be conducted on alternate weeks and documented on vessel log. Vessel had been conducting such drills on a monthly basis.
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: CG inspectors witnessed sucessful fire drill, which was properly logged on ship's rough log.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 May 2024
Resolved
Abandonship drills must be completed on alternate weeks and properly logged on ship's log. Abandonship drills have been conducted on a monnthly basis per company's SMS matrix.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 9 September 2025
Resolution: CG inspectors witnessed sucessful fire drill, which was properly logged on ship's rough log.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 February 2023
Resolved
Vessel shall maintain watertight integrity. Vessel had the ER escape hatch and ER escape WTD that allows air and/or light through.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2023
Resolution: ABS Cleared Deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 February 2023
Resolved
Vessel shall maintain watertight integrity. Vessel had 2 watertight penetrations that allowed the cable to move freely.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2023
Resolution: ABS cleaered deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 February 2023
Resolved
Fire pump shall be self priming & able to reach 50PSI. Fire pump needed to be primed and the fire main purged of air.
Action required: 10 - Deficiency Rectified
Resolved 3 February 2023
Resolution: Fire pump was primed and fire main was purged of air. Vessel was able to run fire pump and maintain at least 50psi.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2021
Resolved
Fire Detection Panel shall have batteries with enough capacity for 3 hours of continues operation. The Fire Detection Panel did not have power when the vessel secured power to the test emergency systems. Vessel is restricted to prior to departure with a requirement of having a roving watch should the vessel loose power.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 13 May 2021
Resolution: ABS Surveyor witnessed the changing of the batteries and the proper operation of the system without ships power.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2021
Resolved
Vessel shall maintain each lifesaving appliance and must be in good working order IAW 46CFR161.010. All self-igniting light attached to the life buoys had expired batteries (October of 2020).
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 13 May 2021
Resolution: Vessel bought and installed new batteries for the self-igniting lights. Vessel texted receipt of the new batteries.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2021
Resolved
A fire drill must be held on each vessel , normally on alternate weeks and properly logged. Vessel had been operating since 28 April 2021 without a logged fire drill.
Action required: 10 - Deficiency Rectified
Due 13 May 2021
Resolved 13 May 2021
Resolution: Vessel conducted a fire-drill in the galley and the Master logged the drill in the log.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 14 February 2020
Resolved
Emergency escape for engine room can not be able to be locked from the outside.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 February 2020
Resolved 14 February 2020
Resolution: Vessel crew members resolved issue at the conclusion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 February 2020
Resolved
Life jacket in the engine room needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 February 2020
Resolved 14 February 2020
Resolution: Vessel crew members replaced the life jacket at the conclusion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020
Resolved
Both the port and starboard SSDG F/O supply lines are corroded and cracked. Vessel must provide F/O lines that comply with SAE-J standards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 19 February 2020
Resolution: Received photographs for the replacement of the worn fuel hoses.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 January 2018
Resolved
Vessel did not have adequate donning placard instructions posted in areas of life jacket donning. Provide permenant life jacket donning placards in vicinity of donning areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 14 March 2018
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 January 2018
Resolved
Vessel last updated chart for area of operation was 04/17. Vessel to provide up to date charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 14 March 2018