KOURION is a 2012 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in July 2026, along with 2 deficiencies and 3 operational controls, 1 with no removal date recorded.
Records from 2016 to 2026. Most recent: operational control imposed, 9 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29954 - Convention (Subpart B), Gross Ton 13429 - Convention (Subpart B), Net Ton 60976 - Displacement, Ton 50209 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
9 July 2026Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8433563
22 March 2026PSC B · COC-CHEM & TVE Renew · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8324401
23 April 2023Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7673827
10 January 2023Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7619172
18 December 2022COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7609099
25 October 2021PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7336755
10 May 2018Administrative Inspection · COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6411096
26 January 2018COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6344356
13 January 2017Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6067944
30 October 2016Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6031848
30 October 2016Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6031851
18 January 2016COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5799120
18 January 2016Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5799156
12 January 2016Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5796005
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2026Resolved
ELECTRICAL EQUIPMENT, CABLES, AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH THE STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED DAMAGE TO THE EXPLOSION PROOF LIGHTING SEAL IVO VESSEL FOREPEAK.
74 SOLAS VII/10.1
IBC CODE 10.1.4
Action required: 705 - Other - as specified
Resolved 22 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 22 March 2026Resolved
THE EQUIPMENT SHALL BE SECURED IN SUCH A MANNER AS TO NOT INTERFERE WITH ANY ABANDONMENT PROCEDURES. PSCO OBSERVED LIFEBOAT EQUIPMENT FOR PORT & STBD LIFEBOATS BLOCKING 05 SEATS ONBOARD.
74 SOLAS (20) III/13.1.4
LSA CODE 4.4.8
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2026
Resolved 30 March 2026
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.