Inspection history · 5
24 September 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6819681
11 September 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6805422
28 June 2018
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6463792
23 June 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6181331
3 May 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5862297
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2019
Resolved
FIRE PROTECTION SYSTEMS AND FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE PROPERLY TESTED AND INSPECTED. FLEXIBLE HOSES ON FIXED CO2 FIREFIGHTING SYSTEM FOUND PAST 10 YEAR REPLACEMENT DATE AS PER ADMINISTRATION'S GUIDELINES AND MSC.1/CIRC.1318. 74 SOLAS (04 CONS) II-2/14.1.2 ; MSC.1/CIRC.1318 ; CIRC.1318 ; 17BC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2019
Resolution: PSC NOLA received proper documentation from the vessel satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 11 September 2019
Resolved
LIFEBOAT RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING. 50% OF LIFEBOAT RATIONS WERE NOT IN AIRTIGHT PACKAGING. 74 SOLAS (2014 CONS) III/34 ; LSA CODE 4.4.8.12 ; 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 September 2019
Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING. 01 CLASS A BOUNDARY DOOR IN MACHINERY SPACE FOUND WITH SELF-CLOSING DEVICE REMOVED. 01 CLASS A BOUNDARY DOOR IN MACHINERY SPACE NOT SELF-CLOSING PROPERLY. 74 SOLAS (04 CONS) II-2/9.4.2.1 ; 10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 23 June 2017
Resolved
0615 - Rescue Boats - Rescue boats shall be stowed in a state of continous readiness for launching in not more than 5 minutes. The motor of the rescue boat did not initially start. Cause during investigation was found to be engine cowling cover secured and spark plug wire was knocked loose during last resecuring of outboard engine cover. SOLAS (14CONS.)III/14.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 July 2017
Resolved 23 June 2017
Resolution: The Chief Engineer and Electrician found the cause as to why the rescue boat did not start in about 12 minutes.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 3 May 2016
Resolved
0615 - Lifesaving equipment - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. PSCO observed the rescue boat's engine would not run. Second engineer bled fuel line and repaired malfunction on outboard engine. -74 SOLAS 14 cons. III/14.1
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 3 May 2016
Resolution: Second engineer bled the fuel line and fixed malfunction on outboard engine.
Fire Fighting › Combustible Materials › Insulation
Issued 3 May 2016
Resolved
0999 - Safety in General - Means shall be provided to control leaks of flammable liquids. PSCO observed excessive soaked lagging in the purifier room. - 74 SOLAS 14 cons. II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2016
Resolved 5 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.