BBC RHONETAL is a 2013 freight ship. The Coast Guard has recorded 16 inspections since 2017, most recently in July 2026, along with 9 deficiencies and 4 operational controls.
Records from 2017 to 2026. Most recent: inspection, 8 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25880 - Displacement, Metric Ton 14941 - Convention (Subpart B), Gross Ton 17577 - Dead Weight, Metric Ton 6340 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
8 July 2026PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8432530
27 July 2025Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8195360
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 August 2024Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE RISK OF FIRE OR EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINISTRATION. LOOSE CONNECTIONS ON EXPLOSION PROOF LIGHTING FIXTURES WERE IDENTIFIED IN BRIDGE BATTERY ROOM HAZARDOUS AREA.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2024
Resolved 7 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 7 August 2024Resolved
EACH SURVIVAL CRAFT SHALL BE STOWED... FULLY EQUIPPED AS REQUIRED BY THIS CHAPTER AND THE CODE. THERMAL PROTECTIVE AIDS ARE NOT PERMANENTLY STORED IN THE RESCUE BOAT AS REQUIRED BY THIS CHAPTER AND NOTED IN SMS.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2024
Resolved 7 August 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 July 2022Resolved
04114 - Emergency Systems - Where the emergency source of electrical power is a generator it shall be provided with a transitional source of emergency electrical power as specified in paragraph 4 unless an emergency generator is provided capable both of supplying the services mentioned in that paragraph and of being automatically started and supplying the required load as quickly as is safe and practicable subject to a maximum of 45s. Ship's emergency generator electrical started is inoperable, resulting in the emergency generator unable to start automatically.
SOLAS 20 II-1/43.3.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 December 2019Resolved
The piping for the distribution of fire extinguishing medium shall be arranged and discharge nozzles so positioned that a uniform distribution medium is obtained. Several connections from the CO2 bottles to the distribution manifold were found loose.
SOLAS 2014 A CH II-2 Reg 10.5.11
FSS CH 5 2.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2019
Resolution: Service report received from [name withheld] stating that they had attended the vessel, inspected and tightened the CO2 flex loops at both ends from cylinder and at manifold. Servicing report attatched in Documents.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 18 December 2019Resolved
A ship, except a ship of less than 26 ft in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station. A "Discharge of Oil Prohibited" Placard was not found in the vicinity of the oily water seperator overboard discharge valve.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2020
Resolution: Vessel provided photographic evidence that I new placard had been installed, all sat.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 11 May 2018Resolved
01-0615 All lifesaving appliances shall be in working order and ready for immediate use. PSCO observed Rescue Boat unable to start within 5 minutes time frame due to inoperable battery. 74SOLAS(14) II-2/20.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2018
Resolution: Letter from class
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 May 2018Resolved
02-0725 The piping and associated equipment shall be adequately supported. Supporting systems for CO2 Bottles inadequately maintained. Interior, end of row bottles hoses found to be folded over and kinked due to bottle movement. 74SOLAS(14) II-2/10.4.1.1.1 FSS Code 5.2.1.2.5 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2018
Resolution: Letter from class
03-1730 The condition of the ship and its equipment shall be maintained to conform with the provisions of the convention. PSCO observed OWS display to be nonfunctional and crew unable to produce clean water from system. MARPOL Annex 1 Reg 6.4.1 40ab
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2019
Resolution: Received class report attesting to condition of opily water seperator and observed operational test during exam.
04-0750 Means shall be provided to control leaks from flammable liquids. #2 generator was leaking diesel fuel from high pressure fuel pump. 74SOLAS(14) II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2018
Resolved 11 May 2018
Resolution: PSCO OBSERVED FUEL OIL WAS CLEANED AND LEAK RECTIFIED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.