Records from 2016 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 15
28 April 2026
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8356303
7 April 2026
Construction Oversight
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8344079
14 April 2025
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8111500
27 April 2023
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7676912
18 April 2023
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7671051
18 April 2022
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7432952
18 May 2021
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7200313
16 April 2021
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7176614
27 April 2020
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6944474
10 June 2019
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6722424
19 April 2019
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6671480
7 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6437201
20 June 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6243278
24 April 2017
Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6131498
6 June 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5915689
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 April 2026
Resolved
The vessel's O/O was not able to provide training and drill logs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 21 May 2026
Resolution: Received email from O/O with updated log.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2026
Resolved
The lifejacket container on the vessel is marked off the old COI instead of the new one that reduced the passenger count rom 20 to 19.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2026
Resolved 21 May 2026
Resolution: Received picture of corrected lifejack container marking.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2022
Resolved
Fire buckets need lines attached.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Lines attached to buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2022
Resolved
Electric submersible bilge pump did not work in auto mode.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Bilge pump works as needed.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 18 April 2022
Resolved
Vessel needs emergency broadcast placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Placard installed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 April 2022
Resolved
Vessel needs emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Drills conducted with Captains.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2022
Resolved
Ring buoy needs line attached. Ring buoy light needs non corrosive clip.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Line and corrosive clip installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 April 2022
Resolved
Vessel needs new flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2022
Resolved 6 May 2022
Resolution: Flares provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 April 2020
Resolved
Vessel lacked means of closing-off air to engine space
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 25 June 2020
Resolution: Vessel has bouys cut in half that fit snugly in the dorade closing off air in the event of fire.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2020
Resolved
Flame impingement bowl needs plugs
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 25 June 2020
Resolution: Impingement bowl has brass plugs installed vice plastic petcock.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 April 2020
Resolved
Vessel was missing flares
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 25 June 2020
Resolution: All flares onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 April 2020
Resolved
Vessel was missing fire buckets w/ lanyards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 25 June 2020
Resolution: New fire buckets and lanyards placed onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2020
Resolved
Vessel is missing 2ea portable lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 25 June 2020
Resolution: Portable lights onboard
Fire Fighting › Fire Bucket › Quantity
Issued 6 June 2016
Resolved
Provide 03, 2.5 gallon fire buckets
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Buckets provided
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 June 2016
Resolved
Provide COI, stability letter, state registration and operators license on board the vessel.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016
Lifesaving › Visual Distress Signals (General) › Storage
Issued 6 June 2016
Resolved
Label flare box as "Distress Signals"
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 6 June 2016
Resolved
Service Fireboy fire supperssion system.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 June 2016
Resolved
Keep passenger count available on shore.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Policy established to call in passengers on the radio to the office.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 6 June 2016
Resolved
Provide 01 adult and 01 child life jackets.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Life jackets provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 June 2016
Resolved
Provide correct life jacket count.
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 8 September 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 June 2016
Resolved
Seperately store adult and child life jackets.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016
Resolution: Life jackets stored separately.