Records from 2016 to 2024. Most recent: inspection, 8 January 2024.
Inspection history · 11
8 January 2024
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7844071
19 January 2023
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7616351
29 September 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7568440
17 July 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7258638
17 July 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7262100
17 June 2021
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7211174
29 June 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6728882
27 June 2019
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6727148
26 June 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6783518
30 July 2018
Deficiency Check · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6482242
1 March 2016
Ballast Water Examination · PII Safety Exam · MARPOL Annex VI Survey · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5822057
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2023
Resolved
MAIN AND EMERGENCY SWITCHBOARDS SHALL BE SO ARRANGED AS TO GIVE EASY ACCESS AS MAY BE NEEDED TO APPARATUS AND EQUIPMENT, WITHOUT DANGER TO PERSONNEL. PSCO OBSERVED REFRIGERATOR OBSTRUCTING ENTRANCE TO THE REAR OF SWITCHBOARD IN ENGINE CONTROL ROOM.
SOLAS74(2014 CONS) II-1/45.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 January 2024
Resolution: Refrigerator removed from ECR, Main/Auxilary Switch Board access no longer obstructed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 January 2023
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS. PSCO OBSERVED SCREENS ON BALLAST WATER PUMPS NO. 1 AND NO. 2 DOES NOT PROVIDE SUFFICIENT PROTECTION FROM ROTATING SHAFT.
SOLAS74(2014 CONS) II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 January 2024
Resolution: PSCO Observed guards have been fitted to ballast water pumps no. 1 and 2 to protect persons on board from danger/risk of injury from rotating shaft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced engine start failure due to unknown causes.
74 SOLAS (14) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2021
Resolution: Received class report attesting to repairs. Deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2018
Resolved
0715-Fire fighting -detection- suitable instructions and components spares for testing and maintenance shall be produced, detectors shall be periodically tested using equipment suitable for the the types of fire to which the detector is designated to respond. Vessels crew was testing flame detectors with cigarette lighter due to broken lamp tester.
74SOLAS II-2/7.2.2
FSS CODE 9.2.5.2
16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 31 July 2018
Resolution: Vessel purchase a new UV lamp for testing and proved operation of system and means to test.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 July 2018
Resolved
0720-Fire Fighting Equipment- Fire fighting system and appliances shall be kept in good working order and readily available for immediate use. Portable extinguisher which has been discarded shall be immediately recharged or replaced with an equivalent unit. Portable fire extinguisher in life boat was low to the point of red on the gauge.
74 SOLAS(14) II-2/14.2.1.2
10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 30 July 2018
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 July 2018
Resolved
0683-Embarkation Rescue Boat- Muster and embarkation stations shall be adequately illuminated by lighting. 02 Lights were out on the rescue boat embarkation deck.
74SOLAS (14) III/11.4
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 July 2018
Resolved 30 July 2018
Resolution: Corrected on the spot