Records from 2016 to 2025. Most recent: inspection, 7 October 2025.
Inspection history · 27
7 October 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8248960
3 April 2025
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8106351
1 April 2025
PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8102928
30 September 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7569197
19 September 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7561851
13 September 2022
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7558443
12 September 2022
PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7555303
9 August 2022
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7528752
9 August 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7538214
27 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7460462
26 April 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7438516
19 April 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7434260
13 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7430330
4 January 2022
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7375267
4 January 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7376106
27 December 2021
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7383560
26 December 2021
PSC A
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7372471
1 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7343074
6 October 2021
PSC B · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7325534
19 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6980876
3 January 2020
Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6880505
11 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6866268
26 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6568682
4 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6433559
18 October 2017
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6289946
14 September 2017
ISPS II Exam · Canadian Vsl Safety Exam (D9 only)
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6265255
28 July 2016
Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5959174
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 April 2025
Resolved
The diamond, lines and letters must be painted in white or yellow on a dark ground or in black on a light ground and permeanently marked on the side of the vessel. Load Line not contrasting with hull. 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 7 October 2025
Resolution: Recieved class report from Llyods attesting that the load lines were repainted.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 April 2025
Resolved
The general construction of the vessel shall be such as to minmize fire hazards insofar as is reasonable and practical. Doors to fuel oil purifying room need gasket replaced because of detoriating condition. 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 7 October 2025
Resolution: Recieved class report attesting that the Fuel Oil purifier room door gaskets renewed with approved ones.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 1 April 2025
Resolved
All connections in the transfer system are leak free except that a component in the transfer system.. High fuel oil pump gasket failing. Fuel oil pump leaking into a quart sized bucket. 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 7 October 2025
Resolution: Receieved class report attesting that the Fuel oil pump seal was renewed, and no sign of leakage noted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 September 2022
Resolved
Except as provided in chapter 37 and section 3505 of this title, a foreign vessel of a country having inspection laws and standards similar to those of the United States and that has an unexpired certificate of inspection issued by proper authority of its respective country, is subject to an inspection to ensure that the condition of the vessel is as stated in its current certificate of inspection. A foreign country is considered to have inspection laws and standards similar to those of the United States when it is a party to an International Convention for Safety of Life at Sea to which the United States Government is currently a party. A foreign certificate of inspection may be accepted as evidence of lawful inspection only when presented by a vessel of a country that has by its laws accorded to vessels of the United States visiting that country the same privileges accorded to vessels of that country visiting the United States.
Vessel's documentation does not meet the requirements in the bilateral agreement between United States and Canada. Vessel must comply with international regulations or reciprocity requirements per the bilateral agreement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 13 September 2022
Resolution: Flag issued corrected CIC to vessel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2022
Resolved
Each conductor of a control, interlock, or indicator circuit must be disconnected from all sources of power by a disconnect device actuated by the opening of the controller door.
The HFO and MGO purifier controller interlocks were not functioning properly, allowing the controller doors to be opened without securing power to the controller.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2022
Resolved 30 September 2022
Resolution: Vessel Deck Superintendent submitted [name withheld], picture evidence and class report attesting to satisfaction of repairs (see deficiency history documents).
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 December 2021
Resolved
The number of pounds of carbon dioxide (CO2) required for each space shall be appropriate for the space. The purifier room is protected by a CO2 extinguishing system. Both fire doors accessing the purifier room were secured in the open position, increasing the required quantity of CO2 to effectively extinguish a fire in that space.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2021
Resolved 26 December 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 October 2021
Resolved
At each inspection for certification and periodic inspection, the inspector shall examine the tank tops and bilges in the machinery spaces to see that there is no accumulation of oil which might create a fire hazard.
Oil was noted leaking through an engine room deck drain below the STBD generator, onto a heating furnace, causing a fire hazard. Excessive oil was noted throughout the engine room to include 03 buckets in the purifier room, oil covering the deck under the STBD generator, oil soaked cardboard installed as a shroud around a generator coupling, and vacuums with oil in them. The quantity observed is a fire hazard.
46CFR91.25-45(a) 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2021
Resolved 1 November 2021
Resolution: Deficiency rectified by class report. (see documents)
Operations/Management › Pollution › Report of Discharge
Issued 14 September 2017
Resolved
03-Ships Logbooks/Compulsory Entries-The Master in charge of a ship shall ensure that a written record is maintained on the ship on each disposal to a reception facility. 05 discharges of garbage to the reception facility were not logged in the Garbage Record Book. 33CFR151.55(a)(1)/MARPOL Annex V
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 14 September 2017
Resolution: Master was informed that entries were not being logged and was eductated on requirements.
Fire Fighting › Means of Escape › Doorways
Issued 14 September 2017
Resolved
01-Other-On 01NOV16 LR on behalf of TC conducted a survey of the vessels fire control plan during which time the Emergency Escape Door (D191) was found functioning. The Emergency Escape Door (D191) was warped not meeting A-60 self closing standards. 33USC1223
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 October 2017
Resolved 18 October 2017
Resolution: CLASS REPORT RECIEVED ATTESTING TO SATISFACTORY CONDITION OF THE VESSEL (SEE DOCUMENTS)
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 September 2017
Resolved
02-Detection-Vessel must adhere to fire control plan. In the windless space 02 smoke detectors were covered with rags rendering them inoperable. 33USC1223
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 October 2017
Resolved 18 October 2017
Resolution: CLASS REPORT RECIEVED ATTESTING TO SATISFACTORY CONDITION OF THE VESSEL (SEE DOCUMENTS)