BOKALIFT 1

BOKALIFT 1 is a 2012 freight ship. The Coast Guard has recorded 4 inspections since 2024, most recently in July 2026, along with 4 deficiencies.

Records from 2024 to 2026. Most recent: inspection, 12 July 2026.

Built
2012
Last inspected
12 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 July 2026
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2024–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9592850
1225424
Flag
CYPRUS
Maury page id
psix-1225424

Documentation record

Tonnage as PSIX records it39379 - Convention (Subpart B), Gross Ton
11813 - Convention (Subpart B), Net Ton
36653 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

12 July 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8436090
27 April 2026 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8353858
1 September 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7993593
4 May 2024 PSC A
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7903996

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 May 2024 Resolved
Where the main steering gear comprises two or more identical power units is so arranged that after a single failure in one of the power units the defect can be isolated so that steering capability can be speedily regained. Port steering pumps do not automatically restart from standby after a power failure.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 4 May 2024
Resolved 6 May 2024
Resolution: Received satisfactory class report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 May 2024 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Cabling from Portable Accommodation Modules on deck are not properly supported.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 6 May 2024
Resolution: Received satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 May 2024 Resolved
The fire integrity of the division shall be maintained at openings and penetrations. Cable wiring penetrations from the Engine Room overhead does not have insulation between "A" boundaries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2024
Resolved 6 May 2024
Resolution: Received satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 May 2024 Resolved
Power Ventilations of machinery spaces shall be capable of being stopped from a position outside the space being served. Engine Room ventilation louvers failed to remotely close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 May 2024
Resolved 4 May 2024
Resolution: Crew demonstrated proper function of Ventilation

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.