UAL CASTLE is a 2013 freight ship. The Coast Guard has recorded 27 inspections since 2016, most recently in February 2026, along with 4 deficiencies and 9 operational controls.
Records from 2016 to 2026. Most recent: inspection, 17 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it7227 - Convention (Subpart B), Gross Ton 3124 - Convention (Subpart B), Net Ton 10252 - Dead Weight, Metric Ton 13976 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 27
17 February 2026Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8311955
10 February 2026Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8308942
5 February 2026Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8306690
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 13 September 2021Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one International Shore Connection. Connection shall be kept onboard together with a gasket, four bolts, four nuts, and eight washers. Port State Control Officer found one connection missing the gasket and the other had bolts that were unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 September 2021
Resolved 13 September 2021
Resolution: Vessel replaced hardware and gasket for International Shore Connection prior to departure of the examination team.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 August 2018Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations.
The vessel experienced a loss of propulsion that resulted in a grounding within the Houston Ship Channel. This condition posed a hazardous condition within the navigable waters of the United States. Preliminary reports from vessel's crew indicates that a probable cause of the loss of propulsion is an oil mist detector activiating incorrectly; sudden issue with oil mist detector resulted in a hazardous situation.
Oil mist detector is not listed on vessel's critical equipment list (Saftey Management System 5 - 5.4).
Submit evidence to [email withheld] detailing how this hazardous situation was reported to the company, investigated, and analyzed with the objective of improving safety, including the implementation of corective action and measures intended to prevent recurrence (as detailed and required in ISM A/9).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2018
Resolved 24 September 2018
Resolution: Reviewed company audit of incident and determined that satisfactory corrective actions were taken to avoid reoccurence.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 20 February 2018Resolved
9800 -Other(Clearly Hazardous)- Maintenance, testing, and inspection shall be carried out based on guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed that the crew did not have the proper equipment on board to test the flame detection systems throughout the vessel. SOLAS 74(a) 2014 cons. II-2/14.2.2.1 40a
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2018
1499 - Other (Prop. & Aux. Machinery)- Means shall be provided to control leaks of flammable liquids. PSCO observed excessive leaks on main engine fuel pump casing and injectors creating a fire hazard for vessel and crew. SOLAS 74(a) 2014 cons. 11-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 February 2018
Resolution: 21FEB18: recieved class report from BV stating they did not attend but accepted picutres and statement from CE stating outstanding deficiency has been rectified. CE had cleaned excess FO and replaceed o-rings/gaskets, tightned fitings. See narative.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.