Records from 2014 to 2025. Most recent: inspection, 28 February 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
28 February 2025
In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8087978
4 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874084
12 April 2023
COI Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7664239
12 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7449402
3 March 2021
Drydock Extension · MTSA Verification · Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7149374
25 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6942949
17 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6717011
3 April 2018
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6383960
26 March 2018
Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6381091
9 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6371034
15 August 2017
Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6241325
2 May 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5867593
28 April 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5864880
27 August 2015
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5228024
25 June 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4898158
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 4 March 2024
Resolved
Each vessel must comply with 47 CFR part 80 as applicable. Vessel's radio was not fully functional on emergency power due to backup battery failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2024
Resolution: Vessel replaced backup battery. Sent receipt and video of operational test.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 March 2024
Resolved
In each crew berthing area and wash area, the owner or operator must be equipped with information in a visible location regarding sexual assault and sexual harrassemnt, retaliation, and drug and alcohol usage and the procedures and resources to report crimes, including sexual assault and sexual harassment IAW 46 USC 11101 and CVC Policy Letter 23-04. Vessel had not yet equipped each berthing areas and wash area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2024
Resolution: Company HSE/HR created information poster for SASH information requriements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 March 2024
Resolved
The following tests and inspections must be carried out weekly: (b)Each engine of a lifeboat or rescue boat must be run ahead and astern for NLT 3 minutes. Vessel was testing the engine every two weeks per preventative maintenance schedule.
Action required: 10 - Deficiency Rectified
Resolved 4 March 2024
Resolution: Educated Master and Crew. Recommended to amdend the Preventative Maintenance Checklist.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 April 2023
Resolved
A Class-1 watertight door must be designed to withstand a head of water equivalent to the depth from the sill of he door to the bulkhead deck.
Watertight door between engine rooms was not adjusted properly. Gasket was showing signs of deterioration.
Replace gasket and adjust door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 17 April 2023
Resolution: Rcvd pictures of new gasket installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 April 2023
Resolved
All systems for detecting smoke and fire, including sensors and alarms, must be inspected and tested.
Independent smoke alarms are past the replacement date cited by the manufacturer. Replace smoke alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 5 May 2023
Resolution: New smoke detectors installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 March 2021
Resolved
Vessel shall comply with 47 CFR Part 80. Vessel's port VHF radio was not able to transmit or receive to other vessels or to Sector New Orleans. Vessel shall have a licensed FCC Radio Technion to ensure the port radio is able to transmit and receive.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2021
Resolved 5 March 2021
Resolution: Vessel provided Tech report stating the VHF Radio and Antennae were replaced. Technition tested radio satisfactory. Deficiency Cleared via email to Vessel Rep.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 15 August 2017
Resolved
Low cooling water alarms are inoperable on both main diesel generator prime movers and need to be repaired or replaced prior to operating to the satisfaction of a CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 24 August 2017
Resolution: Repaired switches.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 August 2017
Resolved
Emergency light for the rescue boat embarkation station located at the starboard leg tower did not work and needs to be repaired or replaced prior to operating the vessel to the satisfaction of the attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 18 August 2017
Resolution: E-Light repaired.
Stability › Watertight Integrity › Coaming
Issued 27 August 2015
Resolved
The port and stbd. engine room escape scuttle coaming were rusted and dirty making it difficult to open and close the scuttle.
Due 18 September 2015
Resolved 14 September 2015
Resolution: Cleaned off rust and greased fittings, all sat.